In Vitro Comparison of Trueness and Precision of Real Time Library Matching with Medit SmartX on Full Arch Implant Scanning Accuracy with Scan Ladder
Preprint
- 5 September 2025
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background: Accurate transfer of implant positions is essential for the long-term success of full-arch prosthetic rehabilitation. Photogrammetry is widely regarded as the gold standard for accuracy, but its high cost and complexity limit widespread use. Recent developments in artificial intelligence (AI)-assisted intraoral scanning, such as Medit’s SmartX protocol combined with the Scan Ladder system, may offer a simplified and cost-effective alternative. Methods: This in vitro study evaluated the trueness and precision of full-arch implant scans obtained with the Medit i900 intraoral scanner using SmartX real-time library matching and Scan Ladder scan bodies. A 3Shape E2 desktop scanner served as the reference standard. Six implant positions (35, 33, 31, 41, 43, 45) were scanned across 20 SmartX datasets (n = 120 observations). Average surface deviations were calculated against the master STL using CloudCompare software, and descriptive statistics and two-way ANOVA were performed in SPSS. Results: The SmartX + Scan Ladder workflow achieved a mean deviation of 11.41 μm with a standard deviation of 12.16 μm across all implant positions. Anterior sites (31: 4.7 μm; 45: 6.1 μm) showed the lowest deviations, while posterior sites exhibited slightly higher values (43: 22.5 μm). No mean deviation exceeded 25 μm, and no individual measurement surpassed 45 μm. Implant position was a significant factor influencing accuracy (P < .001), whereas scan iteration had no effect (P > .05). Conclusions: SmartX combined with Scan Ladder achieved trueness and precision within the sub-20 μm range, comparable to reported values for photogrammetry. These findings suggest that high-fidelity, full-arch digital implant impressions can be achieved using this simplified workflow. Further in vivo studies are required to validate clinical applicability under real-world conditions.Keywords
All Related Versions
- Version 1, 2025-09-05, Preprints
- Published version: Dentistry Journal, 13 (11), 533.
This publication has 31 references indexed in Scilit:
- An Overview of Digital Workflows for Precision Implant DentistryJournal of the California Dental Association, 2022
- Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scansThe Journal of Prosthetic Dentistry, 2022
- Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trialJournal of Prosthodontic Research, 2020
- Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scannersJournal of Prosthodontic Research, 2019
- Photogrammetry as an alternative for acquiring digital dental models: A proof of conceptMedical Hypotheses, 2019
- Effect of simulated intraoral variables on the accuracy of a photogrammetric imaging technique for complete-arch implant prosthesesThe Journal of Prosthetic Dentistry, 2018
- Photogrammetric method to measure the discrepancy between clinical and software-designed positions of implantsThe Journal of Prosthetic Dentistry, 2016
- Trueness, precision and accuracy: a critical overview of the concepts as well as proposals for revisionAccreditation and Quality Assurance, 2014
- An in vitro comparison of photogrammetric and conventional complete-arch implant impression techniquesThe Journal of Prosthetic Dentistry, 2013
- Understanding the meaning of accuracy, trueness and precisionAccreditation and Quality Assurance, 2006