RFRick Ferguson

Rick Ferguson

*This is an algorithmically generated author record based on publicly available information.

Rick Ferguson has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In Vitro Comparison of Trueness and Precision of an AI-Driven Real-Time Library Matching Protocol with Irregular Geometry Scan Bodies for Full-Arch Implant Scanning

    by Adam Brian Nulty, Cameron Kelly, Oliver Ambridge, Mark Ambridge, Rick Ferguson, Ashtyn Hoffer

    Background: Accurate digital transfer of implant positions is critical for the long-term success of full-arch prosthetic rehabilitation. Photogrammetry remains the benchmark for accuracy, but its high cost and complexity limit clinical adoption. Artificial intelligence (AI)-driven intraoral scanning protocols incorporating real-time library matching and irregular, individually coded scan bodies have been proposed as accessible alternatives to improve accuracy and reproducibility. Methods: This in vitro study evaluated the trueness and precision of a full-arch implant scanning workflow using an AI-assisted real-time library matching system in combination with irregular multi-geometry titanium scan bodies. A high-accuracy structured-light scanner served as the reference standard. Six implant positions (35, 33, 31, 41, 43, 45) were scanned across 20 datasets (n = 120). Mean surface deviations were calculated against the reference STL using CloudCompare v.2.14. and a two-way ANOVA (α = 0.05) in SPSS tested the effects of implant position and scan iteration. Results: The workflow achieved a mean deviation of 13.55 ± 9.70 μm (range 0.77–43.46 μm) across all positions. Anterior sites showed the lowest deviations (e.g., position 31: 3.95 μm; 45: 5.96 μm), while posterior sites exhibited higher deviations (e.g., position 43: 26.15 μm). No mean deviation exceeded 30 μm, and no individual measurement surpassed 45 μm. Implant position significantly affected accuracy (p < 0.001), whereas scan iteration did not (p > 0.05). Conclusions: Within the limitations of this in vitro model, an AI-assisted real-time library matching workflow used in conjunction with irregular multi-geometry scan bodies achieved accuracy levels well within clinically acceptable ranges for full-arch implant impressions. Although comparable to values reported for photogrammetry under laboratory conditions, clinical equivalence should not be assumed. Further in vivo validation is required to confirm performance under routine clinical conditions.


  • Open Access

    In Vitro Comparison of Trueness and Precision of Real Time Library Matching with Medit SmartX on Full Arch Implant Scanning Accuracy with Scan Ladder

    by Adam Brian Nulty, Oliver Ambridge, Mark Ambridge, Cameron Kelly, Richard Ferguson, Ashtyn Hoffer

    Background: Accurate transfer of implant positions is essential for the long-term success of full-arch prosthetic rehabilitation. Photogrammetry is widely regarded as the gold standard for accuracy, but its high cost and complexity limit widespread use. Recent developments in artificial intelligence (AI)-assisted intraoral scanning, such as Medit’s SmartX protocol combined with the Scan Ladder system, may offer a simplified and cost-effective alternative. Methods: This in vitro study evaluated the trueness and precision of full-arch implant scans obtained with the Medit i900 intraoral scanner using SmartX real-time library matching and Scan Ladder scan bodies. A 3Shape E2 desktop scanner served as the reference standard. Six implant positions (35, 33, 31, 41, 43, 45) were scanned across 20 SmartX datasets (n = 120 observations). Average surface deviations were calculated against the master STL using CloudCompare software, and descriptive statistics and two-way ANOVA were performed in SPSS. Results: The SmartX + Scan Ladder workflow achieved a mean deviation of 11.41 μm with a standard deviation of 12.16 μm across all implant positions. Anterior sites (31: 4.7 μm; 45: 6.1 μm) showed the lowest deviations, while posterior sites exhibited slightly higher values (43: 22.5 μm). No mean deviation exceeded 25 μm, and no individual measurement surpassed 45 μm. Implant position was a significant factor influencing accuracy (P < .001), whereas scan iteration had no effect (P > .05). Conclusions: SmartX combined with Scan Ladder achieved trueness and precision within the sub-20 μm range, comparable to reported values for photogrammetry. These findings suggest that high-fidelity, full-arch digital implant impressions can be achieved using this simplified workflow. Further in vivo studies are required to validate clinical applicability under real-world conditions.


  • Avoiding Complications in Oral Implantology

    by Rick Ferguson, Ferguson, Rick Dmd

    • 1 March 1999
      • Vol. 10  (3) , 19-20

    The use of bioactive glass to enhance implant placement.

    by R Ferguson

    • 1 January 1999
      • Vol. 10  (1) , 1-5

    Use of a porous-surfaced implant system.

    by R Ferguson