Probabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study
Open Access
- 7 February 2026
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (4) , 1323
Abstract
Background/Objectives: Safe placement of sacral vertebra 1 (S1) screws is essential in lumbosacral instrumentation and iliosacral fixation. Existing anatomical safe zones are largely based on averaged geometry and do not provide quantitative probability estimates for permissible deviations from an ideal entry point. This study aims to develop a probabilistic, computed tomography–based (CT-based) safe zone model for S1 screw placement. Methods: This retrospective imaging-based anatomical modeling study will analyze 1000 anonymized lumbosacral CT scans. A reproducible reference entry point will be defined on the lateral S1 projection, and bilateral offset-based virtual screw trajectories will be evaluated. Two independent raters will classify each trajectory as intraosseous or extraosseous. Probabilistic safety maps will be generated by aggregating binary classifications across offsets and directions. Interobserver reliability will be assessed using Cohen’s kappa, and anatomical influences will be analyzed using multivariable regression models. Results: The study is expected to generate continuous probabilistic safety maps illustrating the likelihood of intraosseous S1 screw placement across predefined offset distances and directions from the reference entry point. These maps are anticipated to demonstrate a gradual transition from high to low safety probabilities rather than a binary safe–unsafe boundary, and to identify anatomical factors influencing screw containment. Conclusions: This protocol describes a CT-based probabilistic modeling approach to S1 screw placement that aims to provide a more nuanced and quantitative definition of anatomical safe zones. If successful, the proposed method may improve preoperative planning and intraoperative decision-making by moving beyond averaged geometric constraints toward probability-informed screw placement.Keywords
This publication has 20 references indexed in Scilit:
- Evaluation of screw pull-out from plate fixation of en bloc distal radius resection with ulnar reconstruction: Finite element analysis and comparison with experiments on Thiel cadaversAPL Bioengineering, 2025
- Evaluation of the true lateral fluoroscopic projection for the relation of the S1 recess/foramen to safe corridors in transiliac-transsacral screw placement in human cadaveric pelvesEuropean Journal of Orthopaedic Surgery & Traumatology, 2024
- Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuriesScientific Reports, 2022
- Corridor-diameter-dependent angular tolerance for safe transiliosacral screw placement: an anatomic study of 433 pelvesEuropean Journal of Orthopaedic Surgery & Traumatology, 2021
- Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rodInternational Orthopaedics, 2017
- Percutaneous Placement of Iliosacral Screws Under the Guidance of Axial View Projection of the S1 Pedicle: a Case SeriesScientific Reports, 2017
- Simple mathematical model of sacroiliac screws safe-zone-Easy to implement by pelvic inlet and outlet viewsJournal of Orthopaedic Research, 2016
- Die perkutane transiliosakrale Zugschraubenosteosynthese des hinteren BeckenringsDer Unfallchirurg, 2007
- Technik der perkutanen SI-Verschraubung mit Unterstützung durch konventionellen C-BogenDer Unfallchirurg, 2005
- Internal Fixation of Pelvic Ring FracturesClinical Orthopaedics and Related Research, 1989