Roland Becker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roland Becker has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Nikolai Ramadanov
Center of Orthopaedics and Traumatology, Brandenburg Medical School, University Hospital Brandenburg an der Havel, Brandenburg an der Havel, 14770 Brandenburg, Germany
4 shared publications - Bernd Döring
<!--5--> Zentrum für Orthopädie und Unfallchirurgie Medizinische Hochschule Theodor Fontane 14770 Brandenburg Germany
2 shared publications - Florian Haasters
<!--6--> Schönklinik München Harlaching Harlachinger Straße 51 81547 Munich Germany
2 shared publications - Franz Josef Seibert
Universitätsklinik für Unfallchirurgie, Graz
2 shared publications - Hansjörg Eickhoff
<!--3--> Orthopädie u. Unfallchirurgie, Abteilung Arthroskopie u. Schulterchirurgie GFO‐Kliniken Troisdorf Hospitalstr. 45 53840 Troisdorf Germany
2 shared publications - Hermann Anetzberger
<!--1--> Orthopädische Gemeinschaftspraxis am OEZ Hanauer Str. 65 80993 Munich Germany
2 shared publications
Latest Publications
- Open Access
- 29 July 2026
- Published by Wolters Kluwer Health in International Journal of Surgery
Mid- and long-term outcomes of endoscopic versus open gluteal tendon repair: a systematic review and multilevel meta-analysis
Purpose: Evidence on short-term outcomes of open versus endoscopic gluteal tendon repair is available, but the durability of these results beyond the early postoperative phase remains unclear. To date, no data synthesis has specifically addressed mid- to long-term outcomes. The aim of this study was, therefore, to conduct a systematic review and multilevel meta-analysis to compare mid- and long-term functional and pain outcomes following open versus endoscopic gluteal tendon repair. Methods: PubMed, Embase, CENTRAL, and Epistemonikos were searched through 30 September 2025. Outcomes of open versus endoscopic gluteal tendon repair were synthesized using a multilevel random-effects meta-analysis with restricted maximum likelihood and Hartung–Knapp adjustments. Continuous data were reported as mean differences with 95% confidence intervals, and heterogeneity was assessed with Higgins’ I 2 . Results: Nine studies comprising 264 patients (269 hips) were included. Endoscopic repair demonstrated significantly superior mid- to long-term functional improvement compared with open repair ( F = 7.91, P = 0.01) and greater functional gain over time ( F = 8.79, P = 0.01). Postoperative pain outcomes were comparable between groups ( F = 0.98, P = 0.34), yet endoscopic repair achieved a significantly greater reduction in pain at follow-up ( F = 9.79, P < 0.01). Conclusion: Endoscopic gluteal tendon repair is associated with superior long-term functional outcomes and lower complication rates compared to open repair, supporting its role as the preferred surgical approach for most patients. Level of evidence: IV (systematic review and meta-analysis of Level IV studies).
- 29 July 2026
- Published by Wolters Kluwer Health in International Journal of Surgery
Open AccessMid- and long-term outcomes of endoscopic versus open gluteal tendon repair: a systematic review and multilevel meta-analysis
Purpose: Evidence on short-term outcomes of open versus endoscopic gluteal tendon repair is available, but the durability of these results beyond the early postoperative phase remains unclear. To date, no data synthesis has specifically addressed mid- to long-term outcomes. The aim of this study was, therefore, to conduct a systematic review and multilevel meta-analysis to compare mid- and long-term functional and pain outcomes following open versus endoscopic gluteal tendon repair. Methods: PubMed, Embase, CENTRAL, and Epistemonikos were searched through 30 September 2025. Outcomes of open versus endoscopic gluteal tendon repair were synthesized using a multilevel random-effects meta-analysis with restricted maximum likelihood and Hartung–Knapp adjustments. Continuous data were reported as mean differences with 95% confidence intervals, and heterogeneity was assessed with Higgins’ I 2 . Results: Nine studies comprising 264 patients (269 hips) were included. Endoscopic repair demonstrated significantly superior mid- to long-term functional improvement compared with open repair ( F = 7.91, P = 0.01) and greater functional gain over time ( F = 8.79, P = 0.01). Postoperative pain outcomes were comparable between groups ( F = 0.98, P = 0.34), yet endoscopic repair achieved a significantly greater reduction in pain at follow-up ( F = 9.79, P < 0.01). Conclusion: Endoscopic gluteal tendon repair is associated with superior long-term functional outcomes and lower complication rates compared to open repair, supporting its role as the preferred surgical approach for most patients. Level of evidence: IV (systematic review and meta-analysis of Level IV studies).
- Open Access
- 26 June 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (26) , e49488
Artificial intelligence-guided clavicle fracture detection on plain radiographs: A retrospective diagnostic accuracy study
Extensive research exists on artificial intelligence (AI)-assisted fracture detection in various anatomical regions, but clavicle fractures remain comparatively understudied. This study aimed to compare the diagnostic performance of AI-guided clavicle fracture detection on plain radiographs with that of an experienced orthopedic surgeon. We retrospectively analyzed all clavicle radiographs obtained at our institution between September 11,2023 and October 31,2024 following the clinical implementation of AI-guided fracture detection. Radiological findings confirmed by a senior radiologist served as the reference standard. AI performance was additionally compared with the assessments of an experienced, blinded orthopedic surgeon. Diagnostic performance metrics included accuracy, sensitivity, specificity, Cohen kappa, F1 score, and Youden index. A total of 367 clavicle radiographs were included, comprising 186 anteroposterior (AP) and 181 second-plane views. The mean patient age was 44.6 ± 26.2 years, and 59.4% were male. According to the reference standard, clavicle fractures were present in 96 AP radiographs (51.6%) and 95 second-plane radiographs (52.5%). On AP radiographs, the AI system achieved an accuracy of 97.31%, sensitivity of 95.83%, specificity of 98.89%, Cohen kappa of 0.95, and F1 score of 0.97. Diagnostic performance on second-plane radiographs was similarly high and overall comparable to that of the experienced orthopedic surgeon. This retrospective diagnostic accuracy study shows that AI-guided clavicle fracture detection is highly accurate and reliable, with performance approaching that of an experienced orthopedic surgeon. These findings support the potential role of AI as a diagnostic support tool in clavicle fracture detection, while prospective and multicenter validation remains warranted.
- 26 June 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (26) , e49488
Open AccessArtificial intelligence-guided clavicle fracture detection on plain radiographs: A retrospective diagnostic accuracy study
Extensive research exists on artificial intelligence (AI)-assisted fracture detection in various anatomical regions, but clavicle fractures remain comparatively understudied. This study aimed to compare the diagnostic performance of AI-guided clavicle fracture detection on plain radiographs with that of an experienced orthopedic surgeon. We retrospectively analyzed all clavicle radiographs obtained at our institution between September 11,2023 and October 31,2024 following the clinical implementation of AI-guided fracture detection. Radiological findings confirmed by a senior radiologist served as the reference standard. AI performance was additionally compared with the assessments of an experienced, blinded orthopedic surgeon. Diagnostic performance metrics included accuracy, sensitivity, specificity, Cohen kappa, F1 score, and Youden index. A total of 367 clavicle radiographs were included, comprising 186 anteroposterior (AP) and 181 second-plane views. The mean patient age was 44.6 ± 26.2 years, and 59.4% were male. According to the reference standard, clavicle fractures were present in 96 AP radiographs (51.6%) and 95 second-plane radiographs (52.5%). On AP radiographs, the AI system achieved an accuracy of 97.31%, sensitivity of 95.83%, specificity of 98.89%, Cohen kappa of 0.95, and F1 score of 0.97. Diagnostic performance on second-plane radiographs was similarly high and overall comparable to that of the experienced orthopedic surgeon. This retrospective diagnostic accuracy study shows that AI-guided clavicle fracture detection is highly accurate and reliable, with performance approaching that of an experienced orthopedic surgeon. These findings support the potential role of AI as a diagnostic support tool in clavicle fracture detection, while prospective and multicenter validation remains warranted.
- Open Access
- 7 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (4) , 1323
Probabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study
Background/Objectives: Safe placement of sacral vertebra 1 (S1) screws is essential in lumbosacral instrumentation and iliosacral fixation. Existing anatomical safe zones are largely based on averaged geometry and do not provide quantitative probability estimates for permissible deviations from an ideal entry point. This study aims to develop a probabilistic, computed tomography–based (CT-based) safe zone model for S1 screw placement. Methods: This retrospective imaging-based anatomical modeling study will analyze 1000 anonymized lumbosacral CT scans. A reproducible reference entry point will be defined on the lateral S1 projection, and bilateral offset-based virtual screw trajectories will be evaluated. Two independent raters will classify each trajectory as intraosseous or extraosseous. Probabilistic safety maps will be generated by aggregating binary classifications across offsets and directions. Interobserver reliability will be assessed using Cohen’s kappa, and anatomical influences will be analyzed using multivariable regression models. Results: The study is expected to generate continuous probabilistic safety maps illustrating the likelihood of intraosseous S1 screw placement across predefined offset distances and directions from the reference entry point. These maps are anticipated to demonstrate a gradual transition from high to low safety probabilities rather than a binary safe–unsafe boundary, and to identify anatomical factors influencing screw containment. Conclusions: This protocol describes a CT-based probabilistic modeling approach to S1 screw placement that aims to provide a more nuanced and quantitative definition of anatomical safe zones. If successful, the proposed method may improve preoperative planning and intraoperative decision-making by moving beyond averaged geometric constraints toward probability-informed screw placement.
- 7 February 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (4) , 1323
Open AccessProbabilistic Safe Zone Mapping for S1 Screw Placement Using 1000 Lumbosacral CT Scans: A Study Protocol for a Bilateral, Two-Rater, Multi-Offset Anatomical Modeling Study
Background/Objectives: Safe placement of sacral vertebra 1 (S1) screws is essential in lumbosacral instrumentation and iliosacral fixation. Existing anatomical safe zones are largely based on averaged geometry and do not provide quantitative probability estimates for permissible deviations from an ideal entry point. This study aims to develop a probabilistic, computed tomography–based (CT-based) safe zone model for S1 screw placement. Methods: This retrospective imaging-based anatomical modeling study will analyze 1000 anonymized lumbosacral CT scans. A reproducible reference entry point will be defined on the lateral S1 projection, and bilateral offset-based virtual screw trajectories will be evaluated. Two independent raters will classify each trajectory as intraosseous or extraosseous. Probabilistic safety maps will be generated by aggregating binary classifications across offsets and directions. Interobserver reliability will be assessed using Cohen’s kappa, and anatomical influences will be analyzed using multivariable regression models. Results: The study is expected to generate continuous probabilistic safety maps illustrating the likelihood of intraosseous S1 screw placement across predefined offset distances and directions from the reference entry point. These maps are anticipated to demonstrate a gradual transition from high to low safety probabilities rather than a binary safe–unsafe boundary, and to identify anatomical factors influencing screw containment. Conclusions: This protocol describes a CT-based probabilistic modeling approach to S1 screw placement that aims to provide a more nuanced and quantitative definition of anatomical safe zones. If successful, the proposed method may improve preoperative planning and intraoperative decision-making by moving beyond averaged geometric constraints toward probability-informed screw placement.
- Open Access
- 26 July 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (30) , e39068
Indirect comparison in network meta-analysis between SuperPATH, direct anterior and conventional approach hemiarthroplasty in patients with femoral neck fracture
Background: The aim of the study was to compare the short-term outcome of SuperPATH, direct anterior (DAA) and conventional approach (CA) hemiarthroplasty (HA) in patients with femoral neck fractures using a network meta-analysis. Methods: PubMed, China National Knowledge Infrastructure, Epistemonikos, and Embase were searched until May 31, 2024. In a network meta-analysis, mean differences with 95% confidence intervals were calculated using the Hartung–Knapp–Sidik–Jonkman method and a fixed/random effects model for continuous outcomes, and odds ratios with 95% confidence intervals were calculated using the Mantel–Haenszel method and a fixed/random effects model for dichotomous outcomes. Results: The literature search identified a total of 9 randomized controlled trials on SuperPATH with 762 patients and 8 randomized controlled trials on DAA with 641 patients. In the overall ranking, SuperPATH was placed first, DAA second and CA third. SuperPATH HA was best in 7, second best in 2 and third best in 1 of the 10 outcome parameters. DAA HA was best in 2 and second best in 8 of the 10 outcome parameters. CA HA was best in 1 and third best in 9 of the 10 outcome parameters. In the indirect comparison between SuperPATH HA and DAA HA, SuperPATH HA had a 1.36 point lower visual analog scale at 2 to 7 days postoperatively and a 0.17 lower overall complication rate compared to DAA. Conclusion: For the treatment of patients with femoral neck fractures, SuperPATH HA ranked first, DAA HA ranked second and CA HA ranked third. Based on the results, we recommend that trauma surgeons increase their use of minimally invasive hip HA techniques. It should be noted that SuperPATH HA had a significantly lower overall complication rate compared to DAA HA when the minimally invasive technique was chosen.
- 26 July 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (30) , e39068
Open AccessIndirect comparison in network meta-analysis between SuperPATH, direct anterior and conventional approach hemiarthroplasty in patients with femoral neck fracture
Background: The aim of the study was to compare the short-term outcome of SuperPATH, direct anterior (DAA) and conventional approach (CA) hemiarthroplasty (HA) in patients with femoral neck fractures using a network meta-analysis. Methods: PubMed, China National Knowledge Infrastructure, Epistemonikos, and Embase were searched until May 31, 2024. In a network meta-analysis, mean differences with 95% confidence intervals were calculated using the Hartung–Knapp–Sidik–Jonkman method and a fixed/random effects model for continuous outcomes, and odds ratios with 95% confidence intervals were calculated using the Mantel–Haenszel method and a fixed/random effects model for dichotomous outcomes. Results: The literature search identified a total of 9 randomized controlled trials on SuperPATH with 762 patients and 8 randomized controlled trials on DAA with 641 patients. In the overall ranking, SuperPATH was placed first, DAA second and CA third. SuperPATH HA was best in 7, second best in 2 and third best in 1 of the 10 outcome parameters. DAA HA was best in 2 and second best in 8 of the 10 outcome parameters. CA HA was best in 1 and third best in 9 of the 10 outcome parameters. In the indirect comparison between SuperPATH HA and DAA HA, SuperPATH HA had a 1.36 point lower visual analog scale at 2 to 7 days postoperatively and a 0.17 lower overall complication rate compared to DAA. Conclusion: For the treatment of patients with femoral neck fractures, SuperPATH HA ranked first, DAA HA ranked second and CA HA ranked third. Based on the results, we recommend that trauma surgeons increase their use of minimally invasive hip HA techniques. It should be noted that SuperPATH HA had a significantly lower overall complication rate compared to DAA HA when the minimally invasive technique was chosen.
- 29 June 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (4) , 1471-1479
Ten hours of simulator training in arthroscopy are insufficient to reach the target level based on the Diagnostic Arthroscopic Skill Score
Purpose: Simulator arthroscopy training has gained popularity in recent years. However, it remains unclear what level of competency surgeons may achieve in what time frame using virtual training. It was hypothesized that 10 h of training would be sufficient to reach the target level defined by experts based on the Diagnostic Arthroscopic Skill Score (DASS).Methods: The training concept was developed by ten instructors affiliated with the German‐speaking Society of Arthroscopy and Joint Surgery (AGA). The programme teaches the basics of performing arthroscopy; the main focus is on learning and practicing manual skills using a simulator. The training was based on a structured programme of exercises designed to help users reach defined learning goals. Initially, camera posture, horizon adjustment and control of the direction of view were taught in a virtual room. Based on these skills, further training was performed with a knee model. The learning progress was assessed by quantifying the exercise time, camera path length and instrument path length for selected tasks. At the end of the course, the learners’ performance in diagnostic arthroscopy was evaluated using DASS. Participants were classified as novice or competent based on the number of arthroscopies performed prior to the assessment.Results: Except for one surgeon, 131 orthopaedic residents and surgeons (29 women, 102 men) who participated in the seven courses agreed to anonymous data analysis. Fifty‐eight of them were competents with more than ten independently performed arthroscopies, and 73 were novices, with fewer than ten independently performed arthroscopies. There were significant reductions in exercise time, camera path length and instrument path length for all participants after the training, indicating a rapid increase in performance. No difference in camera handling between the dominant and non‐dominant sides was found in either group. The competents performed better than the novices in various tasks and achieved significantly better DASS values on the final performance test.Conclusions: Our data have demonstrated that arthroscopic skills can be taught effectively on a simulator, but a 10‐h course is not sufficient to reach the target level set by experienced arthroscopists. However, learning progress can be monitored more objectively during simulator training than in the operating room, and simulation may partially replace the current practice of arthroscopic training.Level of evidence: III.
- 29 June 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (4) , 1471-1479
Ten hours of simulator training in arthroscopy are insufficient to reach the target level based on the Diagnostic Arthroscopic Skill Score
Purpose: Simulator arthroscopy training has gained popularity in recent years. However, it remains unclear what level of competency surgeons may achieve in what time frame using virtual training. It was hypothesized that 10 h of training would be sufficient to reach the target level defined by experts based on the Diagnostic Arthroscopic Skill Score (DASS).Methods: The training concept was developed by ten instructors affiliated with the German‐speaking Society of Arthroscopy and Joint Surgery (AGA). The programme teaches the basics of performing arthroscopy; the main focus is on learning and practicing manual skills using a simulator. The training was based on a structured programme of exercises designed to help users reach defined learning goals. Initially, camera posture, horizon adjustment and control of the direction of view were taught in a virtual room. Based on these skills, further training was performed with a knee model. The learning progress was assessed by quantifying the exercise time, camera path length and instrument path length for selected tasks. At the end of the course, the learners’ performance in diagnostic arthroscopy was evaluated using DASS. Participants were classified as novice or competent based on the number of arthroscopies performed prior to the assessment.Results: Except for one surgeon, 131 orthopaedic residents and surgeons (29 women, 102 men) who participated in the seven courses agreed to anonymous data analysis. Fifty‐eight of them were competents with more than ten independently performed arthroscopies, and 73 were novices, with fewer than ten independently performed arthroscopies. There were significant reductions in exercise time, camera path length and instrument path length for all participants after the training, indicating a rapid increase in performance. No difference in camera handling between the dominant and non‐dominant sides was found in either group. The competents performed better than the novices in various tasks and achieved significantly better DASS values on the final performance test.Conclusions: Our data have demonstrated that arthroscopic skills can be taught effectively on a simulator, but a 10‐h course is not sufficient to reach the target level set by experienced arthroscopists. However, learning progress can be monitored more objectively during simulator training than in the operating room, and simulation may partially replace the current practice of arthroscopic training.Level of evidence: III.
- 29 April 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (1) , 349-360
The Diagnostic Arthroscopy Skill Score (DASS): a reliable and suitable assessment tool for arthroscopic skill training
Purpose: To develop and validate a novel score to more objectively assess the performance of diagnostic knee arthroscopy using a simulator.Methods: A Diagnostic Arthroscopy Skill Score (DASS) was developed by ten AGA (AGA‐Society for Arthroscopy and Joint‐Surgery) instructors for the assessment of arthroscopic skills. DASS consists of two parts: the evaluation of standardized diagnostic knee arthroscopy (DASSpart1) and the evaluation of manual dexterity, including ambidexterity and triangulation, using objective measurement parameters (DASSpart2). Content validity was determined by the Delphi method. One hundred and eleven videos of diagnostic knee arthroscopies were recorded during simulator training courses and evaluated by six specially trained instructors using DASS. Construct validity, measurement error calculated by the minimum detectable change (MDC), internal consistency using Cronbach’s alpha and interrater and intrarater reliability were assessed. The Bland–Altman method was used to calculate the intrarater agreement.Results: Six skill domains were identified and evaluated for each knee compartment. DASS, DASSpart1, and DASSpart2 showed construct validity, with experts achieving significantly higher scores than competents and novices. MDC was 4.5 ± 1.7 points for DASSpart1. There was high internal consistency for all domains in each compartment from 0.78 to 0.86. The interrater reliability showed high agreement between the six raters (ICC = 0.94). The evaluation of intrarater reliability demonstrated good and excellent agreement for five raters (ICC > 0.80) and moderate agreement for one rater (ICC = 0.68). The Bland–Altman comparison showed no difference between the first and second evaluations in five out of six raters. Precision, estimated by the regression analysis and comparison with the method of Bland and Altman, was excellent for four raters and moderate for two raters.Conclusions: The results of this study indicate good validity and reliability of DASS for the assessment of the surgical performance of diagnostic knee arthroscopy during simulator training. Standardized training is recommended before arthroscopy surgery is considered in patients.Level of evidence: II.
- 29 April 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (1) , 349-360
The Diagnostic Arthroscopy Skill Score (DASS): a reliable and suitable assessment tool for arthroscopic skill training
Purpose: To develop and validate a novel score to more objectively assess the performance of diagnostic knee arthroscopy using a simulator.Methods: A Diagnostic Arthroscopy Skill Score (DASS) was developed by ten AGA (AGA‐Society for Arthroscopy and Joint‐Surgery) instructors for the assessment of arthroscopic skills. DASS consists of two parts: the evaluation of standardized diagnostic knee arthroscopy (DASSpart1) and the evaluation of manual dexterity, including ambidexterity and triangulation, using objective measurement parameters (DASSpart2). Content validity was determined by the Delphi method. One hundred and eleven videos of diagnostic knee arthroscopies were recorded during simulator training courses and evaluated by six specially trained instructors using DASS. Construct validity, measurement error calculated by the minimum detectable change (MDC), internal consistency using Cronbach’s alpha and interrater and intrarater reliability were assessed. The Bland–Altman method was used to calculate the intrarater agreement.Results: Six skill domains were identified and evaluated for each knee compartment. DASS, DASSpart1, and DASSpart2 showed construct validity, with experts achieving significantly higher scores than competents and novices. MDC was 4.5 ± 1.7 points for DASSpart1. There was high internal consistency for all domains in each compartment from 0.78 to 0.86. The interrater reliability showed high agreement between the six raters (ICC = 0.94). The evaluation of intrarater reliability demonstrated good and excellent agreement for five raters (ICC > 0.80) and moderate agreement for one rater (ICC = 0.68). The Bland–Altman comparison showed no difference between the first and second evaluations in five out of six raters. Precision, estimated by the regression analysis and comparison with the method of Bland and Altman, was excellent for four raters and moderate for two raters.Conclusions: The results of this study indicate good validity and reliability of DASS for the assessment of the surgical performance of diagnostic knee arthroscopy during simulator training. Standardized training is recommended before arthroscopy surgery is considered in patients.Level of evidence: II.