Clinical commissioning of intensity‐modulated proton therapy systems: Report of AAPM Task Group 185
Open Access
- 20 October 2020
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 48 (1) , E1-E30
Abstract
Proton therapy is an expanding radiotherapy modality in the United States and worldwide. With the number of proton therapy centers treating patients increasing, so does the need for consistent, high‐quality clinical commissioning practices. Clinical commissioning encompasses the entire proton therapy system's multiple components, including the treatment delivery system, the patient positioning system, and the image‐guided radiotherapy components. Also included in the commissioning process are the x‐ray computed tomography scanner calibration for proton stopping power, the radiotherapy treatment planning system, and corresponding portions of the treatment management system. This commissioning report focuses exclusively on intensity‐modulated scanning systems, presenting details of how to perform the commissioning of the proton therapy and ancillary systems, including the required proton beam measurements, treatment planning system dose modeling, and the equipment needed.Keywords
This publication has 179 references indexed in Scilit:
- A patient-specific planning target volume used in 'plan of the day' adaptation for interfractional motion mitigationJournal of Radiation Research, 2013
- Golden beam data for proton pencil-beam scanningPhysics in Medicine & Biology, 2012
- Experimental characterization of lateral profiles of scanned proton and carbon ion pencil beams for improved beam models in ion therapy treatment planningPhysics in Medicine & Biology, 2011
- Monitoring proton radiation therapy with in-room PET imagingPhysics in Medicine & Biology, 2011
- Water equivalent thickness values of materials used in beams of protons, helium, carbon and iron ionsPhysics in Medicine & Biology, 2010
- Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissuesPhysics in Medicine & Biology, 2010
- Accuracy of an Automatic Patient-Positioning System Based on the Correlation of Two Edge Images in RadiotherapyJournal of Digital Imaging, 2010
- Monte Carlo investigation of the low-dose envelope from scanned proton pencil beamsPhysics in Medicine & Biology, 2010
- Monte Carlo simulations of the dosimetric impact of radiopaque fiducial markers for proton radiotherapy of the prostatePhysics in Medicine & Biology, 2007
- Effect of anatomic motion on proton therapy dose distributions in prostate cancer treatmentInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007