An Emulated Curve Assisted Fast-Transient Buck Converter With One-Cycle Charge Balance
- 25 February 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (9) , 3317-3328
Abstract
This article proposes an emulated peak/valley curve-assisted fast-transient buck converter that achieves almost one-cycle charge balance (OCB) load transient response. The previous OCB works require three-parameter calibration to mimic the output capacitor’s RLC, and high-speed inductor current sensor. Comparatively, this work fulfills a one-parameter calibration with reduced design complexity. Additionally, we employ a modified double adaptive bound (DAB) hysteretic control to enhance both transient detection speed and output voltage regulation. The prototype chip fabricated in a 180-nm BCD process, exhibits a measured maximum deviation-from-ideal (DFI) rate of 5.5% for output voltage undershoot/overshoot (US/OS) and recovery time under different load-step conditions. This implies that the transient performance is close to the theoretical optimum with the proposed OCB scheme. The measured load regulation is improved to 0.05%/A by the modified DAB scheme.Keywords
Funding Information
- Science and Technology Development Fund, Macau, SAR (0041/2022/A1, 004/2023/SKL)
- Guangdong Basic and Applied Basic Research Foundation (2023B1515130001)
- Research Committee of University of Macau (MYRG-GRG2024-00041-IME)
This publication has 20 references indexed in Scilit:
- An Emulated Peak/Valley Curve Assisted Fast-Transient Buck Converter Achieving Precise One-Cycle Charge Balance with One-Parameter Calibration2024
- A 12V-to-PoL CCC-Based Easy-Scalable Multiple-Phase Hybrid Converter with Auto VCF Balancing and Inactive CF Charging2024
- A 4A 12-to-1 Flying Capacitor Cross-Connected DC-DC Converter with Inserted D>0.5 Control Achieving >2x Transient Inductor Current Slew Rate and 0.73× Theoretical Minimum Output Undershoot of DSD2022
- 27.6 Background Capacitor-Current-Sensor Calibration of DC-DC Buck Converter with DVS for Accurately Accelerating Load-Transient Response2019
- Power Management Techniques for Integrated Circuit Design2016
- 12.6 Capacitor-current-sensor calibration technique and application in a 4-phase buck converter with load-transient optimization2016
- 12.1 A 0.518mm2 quasi-current-mode hysteretic buck DC-DC converter with 3μs load transient response in 0.35μm BCDMOS2015
- 4.2 A 6A 40MHz four-phase ZDS hysteretic DC-DC converter with 118mV droop and 230ns response time for a 5A/5ns load transient2014
- Pulsewidth Modulated Dc‐to‐Dc Power Conversion2013
- Non-linear control of current-mode buck converter with an optimally scaled auxiliary phase2010