Effective cross‐sectional method for timber frame assemblies—definition of coefficients and zero‐strength layers
- 1 July 2018
- journal article
- research article
- Published by Wiley in Fire and Materials
- Vol. 42 (8) , 897-913
Abstract
Summary: The load‐bearing capacity of timber members in fire conditions can be evaluated by an analytical design model known as effective cross‐sectional method (ECSM). For this method, an effective cross section of a member in fire is calculated by decreasing the original cross section by a notional charring depth and a so‐called zero‐strength layer. Then, the load‐bearing capacity can be evaluated by applying the mechanical properties as at ambient temperature to this effective cross section. The ECSM for timber frame assemblies (TFA) exposed to standard fire conditions according to European Norm 1363‐1 has been presented earlier in the European technical guidelineFire Safety in Timber Buildings(FSITB) with a limited field of application. This design model considers the fire protection provided by claddings and a limited range of cavity insulations. To cover the fire protection of a wider range of cavity insulation products, a new design approach has been developed. In this study, the zero‐strength layers for TFA with different cavity insulations are determined by means of a series of thermal and mechanical simulations. This paper proposes the protection coefficient for TFA with generic stone wool products as cavity insulation and zero‐strength layers for TFA with different cavity insulations.Keywords
Funding Information
- Eesti Teadusagentuur (PUT 794)
- European Cooperation in Science and Technology (Action FP 1404, founding for Short Term Scientific)
This publication has 9 references indexed in Scilit:
- Design criteria for insulation materials applied in timber frame assembliesJournal of Structural Fire Engineering, 2017
- Design of Cross-Laminated Timber in FireStructural Engineering International, 2017
- Fire Protection Provided by Insulation Materials—A New Design Approach for Timber Frame AssembliesStructural Engineering International, 2017
- Behavior of Wooden Based Insulations at High TemperaturesEnergy Procedia, 2016
- The Reduced Cross-Section Method for Evaluation of the Fire Resistance of Timber Members: Discussion and Determination of the Zero-Strength LayerFire Technology, 2014
- Strain-based calculation model for centrically and eccentrically loaded timber columnsEngineering Structures, 2013
- Effect of increased charring on the narrow side of rectangular timber cross‐sections exposed to fire on three or four sidesFire and Materials, 2011
- SAFIR: A Thermal and Structural Program for Modeling Structures Under FireEngineering Journal, 2005
- A method for assessing the fire resistance of laminated timber beams and columnsCanadian Journal of Civil Engineering, 1977