Stable Extended Imaging Area Sensing Without Mechanical Movement Based on Spatial Frequency Multiplexing
- 8 February 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (10) , 8195-8203
Abstract
Testing process in industrial profiling depends on the characterization of three-dimensional (3-D) objects with high sensitivity in spatial and temporal domains. Ordinary 3-D measurement instruments scan the image area in the temporal domain; therefore, these techniques experience low temporal stability especially for industrial and biomedical sensing. We propose a novel scan-free extended image instrument for sensing the area of 3-D microscopic objects using an interferometric technique with fixed optical parameters, such as resolution, and without mechanical movement. The technique could accelerate the control process in industrial fault detection and images of biological samples could be obtained in a shorter time. First, a stable system for doubling the image area is introduced. Second, the principles underlying the two-dimensional sampling scheme are introduced to record the maximum image area using a dual multiplexing technique at subsampling frequency. Moreover, a standard factor is presented as a figure of merit to determine the exact image area enhancement. Finally, the feasibility of this technique was demonstrated by sensing reflective and transparent objects with image area of up to 4.3-times that of a single-hologram recording using the square scheme. Furthermore, scan-free monitoring of the photolithography process was demonstrated in real-time. The standard deviation of thickness is 0.48 nm, which demonstrates the subnanometer temporal sensitivity of this technique.Keywords
Funding Information
- Ministry of Science and ICT (MSIT), Korea
- Information Technology Research Center (IITP-2017-2016-0-00464)
- Institute for Information & communications Technology Promotion
- National Research Foundation of Korea (NRF) (NRF-2017R1A2B2003808)
- Korea University Future Research Grant
- BK21 Plus Global Leader Development Division in Brain Engineering
This publication has 33 references indexed in Scilit:
- Diffraction phase microscopy: principles and applications in materials and life sciencesAdvances in Optics and Photonics, 2014
- Doubling the field of view in off-axis low-coherence interferometric imagingLight: Science & Applications, 2014
- White-light diffraction tomography of unlabelled live cellsNature Photonics, 2014
- Marker-free phase nanoscopyNature Photonics, 2013
- Short-coherence off-axis holographic phase microscopy of live cell dynamicsBiomedical Optics Express, 2012
- Quantitative phase spectroscopyBiomedical Optics Express, 2012
- Quantitative phase imaging by three-wavelength digital holographyOptics Express, 2008
- Axial Displacement Measurement of a Single-Crystal Actuator Using Phase-Shift InterferometryIEEE Transactions on Industrial Electronics, 2005
- Variable Structure Control of a Piezoelectric Actuator for a Scanning Tunneling MicroscopeIEEE Transactions on Industrial Electronics, 2004
- Optimized sampling schemes for off-axis holographyUltramicroscopy, 1993