The Fricke dosimeter as an absorbed dose to water primary standard for Ir-192 brachytherapy
- 19 May 2015
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (11) , 4481-4495
Abstract
The aim of this project was to develop an absorbed dose to water primary standard for Ir-192 brachytherapy based on the Fricke dosimeter. To achieve this within the framework of the existing TG-43 protocol, a determination of the absorbed dose to water at the reference position, D(r0,θ0), was undertaken. Prior to this investigation, the radiation chemical yield of the ferric ions (G-value) at the Ir-192 equivalent photon energy (0.380 MeV) was established by interpolating between G-values obtained for Co-60 and 250 kV x-rays.An irradiation geometry was developed with a cylindrical holder to contain the Fricke solution and allow irradiations in a water phantom to be conducted using a standard Nucletron microSelectron V2 HDR Ir-192 afterloader. Once the geometry and holder were optimized, the dose obtained with the Fricke system was compared to the standard method used in North America, based on air-kerma strength.Initial investigations focused on reproducible positioning of the ring-shaped holder for the Fricke solution with respect to the Ir-192 source and obtaining an acceptable type A uncertainty in the optical density measurements required to yield the absorbed dose. Source positioning was found to be reproducible to better than 0.3 mm, and a careful cleaning and control procedure reduced the variation in optical density reading due to contamination of the Fricke solution by the PMMA holder. It was found that fewer than 10 irradiations were required to yield a type A standard uncertainty of less than 0.5%.Correction factors to take account of the non-water components of the geometry and the volume averaging effect of the Fricke solution volume were obtained from Monte Carlo calculations. A sensitivity analysis showed that the dependence on the input data used (e.g. interaction cross-sections) was small with a type B uncertainty for these corrections estimated to be 0.2%.The combined standard uncertainty in the determination of absorbed dose to water at the reference position for TG-43 (1 cm from the source on the transverse axis, in a water phantom) was estimated to be 0.8% with the dominant uncertainty coming from the determination of the G-value. A comparison with absorbed dose to water obtained using the product of air-kerma strength and the dose rate constant gave agreement within 1.5% for three different Ir-192 sources, which is within the combined standard uncertainties of the two methods.Keywords
This publication has 19 references indexed in Scilit:
- Response of the alanine/ESR dosimeter to radiation from an Ir-192 HDR brachytherapy sourcePhysics in Medicine & Biology, 2014
- Sci-Fri AM: Mountain - 03: Current status of the NRC primary standard for 192 Ir HDR brachytherapy sourcesMedical Physics, 2014
- A standard graphite calorimeter for dosimetry in brachytherapy with high dose rate192Ir sourcesMetrologia, 2012
- A dosimetric uncertainty analysis for photon‐emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC‐ESTROMedical Physics, 2011
- Determination of absorbed dose in water at the reference point for an HDR brachytherapy source using a Fricke systemMedical Physics, 2008
- Comparison of air kerma standards of LNE–LNHB and NPL for192Ir HDR brachytherapy sources: EUROMET project no 814Physics in Medicine & Biology, 2008
- Fricke dosimetry: the difference betweenG(Fe3+) for60Co gamma-rays and high-energy x-raysPhysics in Medicine & Biology, 1999
- Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43Medical Physics, 1995
- Wall‐correction and absorbed‐dose conversion factors for Fricke dosimetry: Monte Carlo calculations and measurementsMedical Physics, 1993
- Calibration of 192Ir high‐dose‐rate afterloading systemsMedical Physics, 1991