Abstract
Ti and TiN films with thicknesses of less than one monolayer and up to several nanometers were deposited by magnetron sputtering onto Si and SiO 2 . The samples were transferred immediately after deposition into the analysis chamber without breaking the vacuum to avoid oxide formation and contamination. Analysis was done by means of X‐ray photoelectron spectroscopy (XPS) for elemental and bonding state characterization as well as by angle‐resolved XPS (ARXPS) for nondestructive depth profiling. The XPS measurements indicated different phase formation processes at the interfaces, which were used as the base for the ARXPS data analysis. Growth properties for similarly deposited Ti‐, Ta‐ and W‐based films are compared. Copyright © 2010 John Wiley & Sons, Ltd.

This publication has 19 references indexed in Scilit: