Abstract
Study Design: Basic study.Purpose: This study aimed to utilize finite element (FE) analysis and design of experiment (DoE) techniques to propose and optimize a novel pedicle screw design and compare its pull-out force with that of a control device.Overview of Literature: Pedicle screw-based fixation is the gold-standard treatment for spine diseases, particularly in fusion procedures. However, pedicle screw loosening and breakage still occur in osteoporotic and non-osteoporotic patients. This research investigates screw design modifications to enhance screw-bone interface strength and reduce the likelihood of loosening.Methods: We conceptualized a novel pedicle screw considering vertebral bone morphology and strength differences. A validated FE model was developed and used in conjunction with DoE to determine the screw՚s optimum geometrical parameters. The FE model was validated through simulation and laboratory experiments using the control device. The optimized thread profiles for cortical bone and cancellous bone were determined, with pull-out force as the primary factor for screw design evaluation.Results: FE analysis results for the control device closely matched experimental results, with less than 5% difference. The chosen unique pitch/depth ratio showed maximum pull-out force for cortical bone, while DoE enabled the optimization of design parameters for cancellous bone. The optimized pedicle screw exhibited a 15% increase in pull-out force compared to the control device.Conclusions: The study proposes a novel pedicle screw design with better pull-out strength than the control device. Combining FE analysis with DoE is an effective approach for screw design optimization, reducing the need for extensive prototyping tests. A two-variable analysis suffices for optimizing cortical bone design parameters, while a multi-variable analysis is more effective for optimizing cancellous bone design parameters.Keywords
Funding Information
- Sree Chitra Tirunal Institute for Medical Sciences and Technology (P6234)
This publication has 28 references indexed in Scilit:
- Additive manufacturing of biodegradable porous orthopaedic screwBioactive Materials, 2020
- Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgeryJournal of Robotic Surgery, 2019
- Improvement of bone‐tendon fixation by porous titanium interference screw: A rabbit animal modelJournal of Orthopaedic Research, 2018
- Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone modelsMedical Engineering & Physics, 2016
- Pedicle screw loosening: a clinically relevant complication?European Spine Journal, 2015
- Calcium Triglyceride Versus Polymethylmethacrylate Augmentation: A Biomechanical Analysis of Pullout StrengthSpine Deformity, 2013
- A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element modelMedical Engineering & Physics, 2009
- Effects of bone materials on the screw pull-out strength in human spineMedical Engineering & Physics, 2006
- Failure analysis of broken pedicle screws on spinal instrumentationMedical Engineering & Physics, 2005
- Investigation of fixation screw pull-out strength on human spineJournal of Biomechanics, 2004