Biomechanical evaluation of a short-rod technique for lumbar fixation surgery
Open Access
- 11 August 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 10, 959210
Abstract
Objective: The purpose of this study was to analyze the stability and instrument-related complications associated with fixation of the lumbar spine using the Short-Rod (SR) technique.Methods: Using finite element analysis, this study assessed the stability of a bilateral lumbar fixation system when inserting the pedicle screws at angles of 10°, 15°, and 20° to the endplate in the sagittal plane. Using the most stable construct with a screw angle, the model was then assessed with different rod lengths of 25, 30, 35, and 45 mm. The optimal screw inclination angle and rod length were incorporated into the SR model and compared against traditional parallel screw insertion (pedicle screws in parallel to the endplate, PPS) in terms of the stability and risk of instrument-related complications. The following parameters were evaluated using the validated L4–L5 lumbar finite element model: axial stiffness, range of motion (ROM), stress on the endplate and facet joint, von-Mises stress on the contact surface between the screw and rod (CSSR), and screw displacement.Results: The results showed that the SR model with a 15° screw inclination angle and 35 mm rod length was superior in terms of construct stability and risk of complications. Compared to the PPS model, the SR model had lower stiffness, lower ROM, less screw displacement, and lower stress on the facet cartilage, the CSSR, and screws. However, the SR model also suffered more stress on the endplate in flexion and lateral bending.Conclusion: The SR technique with a 15° screw inclination and 35 mm rod length offers good lumbar stability with a low risk of instrument-related complications.Keywords
This publication has 45 references indexed in Scilit:
- The Biomechanical Effect of Pedicle Screwsʼ Insertion Angle and Position on the Superior Adjacent Segment in 1 Segment Lumbar FusionSpine, 2012
- Effect of Spacer Diameter of the Dynesys Dynamic Stabilization System on the Biomechanics of the Lumbar SpineJournal of Spinal Disorders & Techniques, 2012
- Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategiesJournal of Neurosurgery: Spine, 2011
- Intraoperative Techniques to Reduce the Potential of Set-screw Loosening in Long Spinal ConstructsJournal of Spinal Disorders & Techniques, 2010
- Biomechanical Comparison of Iliac Screws Versus Interbody Femoral Ring Allograft on Lumbosacral Kinematics and Sacral Screw StrainSpine, 2010
- Fractures of the lumbar vertebral endplate in the etiology of low back pain: a hypothesis on the causative role of spinal compression in aspecific low back painMedical Hypotheses, 1999
- Change of Disc Height, Radial Disc Bulge, and Intradiscal Pressure From Discectomy An in Vitro Investigation on Human Lumbar DiscsSpine, 1991
- Three-Dimensional Movements of the Whole Lumbar Spine and Lumbosacral JointSpine, 1989
- Depth of Insertion of Transpedicular Vertebral Screws into Human VertebraeJournal of Spinal Disorders, 1988
- Kinematics of the Whole Lumbar SpineSpine, 1985