Abstract
Heavy ion, focused X-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.
Funding Information
  • National Aeronautics and Space Administration (80NSSC20K0424)
  • Defense Threat Reduction Agency (HDTRA1-16-1-0007)
  • Sandia National Laboratories (LDRD program)

This publication has 25 references indexed in Scilit: