Stephen D. LaLumondiere
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stephen D. LaLumondiere has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Ani Khachatrian
U.S. Naval Research Laboratory, Washington, DC, USA
5 shared publications - Daniele M. Monahan
The Aerospace Corporation, El Segundo, CA, USA
5 shared publications - George N. Tzintzarov
The Aerospace Corporation, El Segundo, CA, USA
5 shared publications - John D. Cressler
Georgia Institute of Technology
5 shared publications - Stephen P. Buchner
U.S. Naval Research Laboratory, Washington, DC, USA
5 shared publications - Dale L. Brewe
Argonne National Laboratory, Argonne, IL 60439 USA
4 shared publications
Latest Publications
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1172-1180
Total-Ionizing-Dose Effects in Integrated Silicon Phase Shifters Using Localized X-Ray Pulses
This study investigates the effects of total ionizing dose (TID) damage on silicon photonic (SiPh) phase shifters using Mach-Zehnder modulators (MZMs). By employing a microbeam X-ray source to irradiate one phase shifter in the MZM structure, we were able to isolate radiation-induced effects on phase shifter performance. The results demonstrate three key TID effects on the Si phase shifter: radiation-induced attenuation (RIA), radiation-induced refractive index change (RIRIC), and phase shifter pinch-off. Using the measured MZM transfer function, we developed formulations of radiation-induced effect, providing a quantitative tool for assessing how TID impacts SiPh modulator performance. Our findings suggest that multiple factors influence the variations in TID effects observed across different dose levels, including TID-induced changes to material structure, free carrier modulation, and band-to-band absorption due to radiation-induced defects. This study highlights the complexity of radiation effects in SiPh devices and provides insights that can guide future efforts to improve radiation tolerance in SiPh systems operating in extreme environments.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1172-1180
Total-Ionizing-Dose Effects in Integrated Silicon Phase Shifters Using Localized X-Ray Pulses
This study investigates the effects of total ionizing dose (TID) damage on silicon photonic (SiPh) phase shifters using Mach-Zehnder modulators (MZMs). By employing a microbeam X-ray source to irradiate one phase shifter in the MZM structure, we were able to isolate radiation-induced effects on phase shifter performance. The results demonstrate three key TID effects on the Si phase shifter: radiation-induced attenuation (RIA), radiation-induced refractive index change (RIRIC), and phase shifter pinch-off. Using the measured MZM transfer function, we developed formulations of radiation-induced effect, providing a quantitative tool for assessing how TID impacts SiPh modulator performance. Our findings suggest that multiple factors influence the variations in TID effects observed across different dose levels, including TID-induced changes to material structure, free carrier modulation, and band-to-band absorption due to radiation-induced defects. This study highlights the complexity of radiation effects in SiPh devices and provides insights that can guide future efforts to improve radiation tolerance in SiPh systems operating in extreme environments.
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1798-1806
A Comparison of Total-Ionizing-Dose Effects in Silicon and Silicon-Nitride Waveguides
The total-ionizing-dose (TID) responses of silicon and low-loss silicon-nitride integrated waveguides are evaluated. Mach–Zehnder interferometers (MZIs), which allow for both TID-induced changes in effective refractive index ( neff ) and transmission losses to be observed, were exposed to 10-keV highly localized X-ray pulses facilitating very high dose irradiation for small exposure areas. TID-induced shifts in neff and transmission losses were observed for both waveguide types above 3 Mrad(Si), with the silicon waveguides exhibiting better radiation resilience for both metrics. Data collected was used to create Ansys-Lumerical simulations to propose potential mechanisms of TID-induced degradation in waveguides. Furthermore, to better understand the effects of neff degradation on other passive components, both silicon and silicon-nitride TID-damaged ring resonators were simulated in MATLAB. Differences in neff changes and transmission losses imply that for high dose environments (> 10 Mrad(Si)), when comparing waveguide types, silicon waveguides will provide similar loss performance and comparably smaller shifts in neff compared to typically lower-loss silicon-nitride waveguides.
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1798-1806
A Comparison of Total-Ionizing-Dose Effects in Silicon and Silicon-Nitride Waveguides
The total-ionizing-dose (TID) responses of silicon and low-loss silicon-nitride integrated waveguides are evaluated. Mach–Zehnder interferometers (MZIs), which allow for both TID-induced changes in effective refractive index ( neff ) and transmission losses to be observed, were exposed to 10-keV highly localized X-ray pulses facilitating very high dose irradiation for small exposure areas. TID-induced shifts in neff and transmission losses were observed for both waveguide types above 3 Mrad(Si), with the silicon waveguides exhibiting better radiation resilience for both metrics. Data collected was used to create Ansys-Lumerical simulations to propose potential mechanisms of TID-induced degradation in waveguides. Furthermore, to better understand the effects of neff degradation on other passive components, both silicon and silicon-nitride TID-damaged ring resonators were simulated in MATLAB. Differences in neff changes and transmission losses imply that for high dose environments (> 10 Mrad(Si)), when comparing waveguide types, silicon waveguides will provide similar loss performance and comparably smaller shifts in neff compared to typically lower-loss silicon-nitride waveguides.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 2116-2124
Direct Measurement of Total-Ionizing-Dose-Induced Phase Shifts in Commercially Available, Integrated Silicon-Photonic Waveguides
In this work, integrated silicon photonic waveguides are exposed to ionizing radiation. A micro-beam X-ray source was utilized to deliver an isolated dose to a waveguide that behaved as one branch of an integrated Mach-Zehnder interferometer (MZI) structure, such that any radiation-induced phase shifts can be directly measured. It is found that the silicon waveguides used in the present study exhibit a non-monotonic change in the effective index of refraction, neff , for both O-band and C-band operation due to radiation exposure. The neff first decreased with increasing dose, which is attributed to native SiO 2 growth in the silicon core. At larger doses, this trend reverses and the observed net change in neff eventually becomes positive. This increase in neff can most likely be attributed to radiation-induced densification of SiO 2 . Overall, it was found that these commercially-available silicon waveguides are sensitive to doses above 1×10 9 rad(Si), and the non-monotonic trends suggest that competing simultaneous mechanisms affect the waveguides under high dose levels.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 2116-2124
Direct Measurement of Total-Ionizing-Dose-Induced Phase Shifts in Commercially Available, Integrated Silicon-Photonic Waveguides
In this work, integrated silicon photonic waveguides are exposed to ionizing radiation. A micro-beam X-ray source was utilized to deliver an isolated dose to a waveguide that behaved as one branch of an integrated Mach-Zehnder interferometer (MZI) structure, such that any radiation-induced phase shifts can be directly measured. It is found that the silicon waveguides used in the present study exhibit a non-monotonic change in the effective index of refraction, neff , for both O-band and C-band operation due to radiation exposure. The neff first decreased with increasing dose, which is attributed to native SiO 2 growth in the silicon core. At larger doses, this trend reverses and the observed net change in neff eventually becomes positive. This increase in neff can most likely be attributed to radiation-induced densification of SiO 2 . Overall, it was found that these commercially-available silicon waveguides are sensitive to doses above 1×10 9 rad(Si), and the non-monotonic trends suggest that competing simultaneous mechanisms affect the waveguides under high dose levels.
- 18 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 626-633
Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting From Heavy-Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation
Heavy ion, focused X-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.
- 18 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 626-633
Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting From Heavy-Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation
Heavy ion, focused X-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.
- 6 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 617-625
Mapping the Spatial Dependence of Charge-Collection Efficiency in Semiconductor Devices Using Pulsed-Laser Testing
By scanning the charge-deposition profile produced by a pulsed laser throughout a device, the spatially dependent charge-collection efficiency (CCE) can be determined. This is demonstrated by extracting the depth-dependent CCE in two photodiodes. The resulting collection efficiency curves are found to be consistent with their device structures and the expected charge-collection mechanisms. By applying the efficiency curves to the charge-deposition curves for both heavy ions and pulsed X-rays, the calculated collected charge values show very good agreement with experimental results. This suggests that the profiles extracted using the laser can help predict charge-collection data from other excitation sources and could improve modeling efforts by determining sensitive volumes.
- 6 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 617-625
Mapping the Spatial Dependence of Charge-Collection Efficiency in Semiconductor Devices Using Pulsed-Laser Testing
By scanning the charge-deposition profile produced by a pulsed laser throughout a device, the spatially dependent charge-collection efficiency (CCE) can be determined. This is demonstrated by extracting the depth-dependent CCE in two photodiodes. The resulting collection efficiency curves are found to be consistent with their device structures and the expected charge-collection mechanisms. By applying the efficiency curves to the charge-deposition curves for both heavy ions and pulsed X-rays, the calculated collected charge values show very good agreement with experimental results. This suggests that the profiles extracted using the laser can help predict charge-collection data from other excitation sources and could improve modeling efforts by determining sensitive volumes.
- 16 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 91-98
Single-Event Transients in SiGe HBTs Induced by Pulsed X-Ray Microbeam
This paper presents an experimental study of singleevent transients induced by pulsed X-rays in SiGe HBTs. Devicelevel transient data and circuit-level upset data from pulsed X-rays are analyzed and compared to those of heavy ions. 2-D TCAD modeling is utilized to understand the source of the differences in the transients. The transient peak from ion-shunt effect is not present in pulsed X-ray transients due to its large spot size and slow pulse transition, both of which lead to lower peak carrier densities. The diffusion “tail”, typically present in transients measured from SiGe HBTs, also differs between the two sources. The charge collection of X-ray has a linear correlation with surface LET across the photon energies of 8-12 keV. For a similar surface LET, the impinging heavy ion pushes the subcollector-substrate junction boundaries of the SiGe HBT deeper, resulting in higher charge collection. SEU screening of shift-registers show that X-ray can detect device sensitive nodes smaller than the beam.
- 16 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 91-98
Single-Event Transients in SiGe HBTs Induced by Pulsed X-Ray Microbeam
This paper presents an experimental study of singleevent transients induced by pulsed X-rays in SiGe HBTs. Devicelevel transient data and circuit-level upset data from pulsed X-rays are analyzed and compared to those of heavy ions. 2-D TCAD modeling is utilized to understand the source of the differences in the transients. The transient peak from ion-shunt effect is not present in pulsed X-ray transients due to its large spot size and slow pulse transition, both of which lead to lower peak carrier densities. The diffusion “tail”, typically present in transients measured from SiGe HBTs, also differs between the two sources. The charge collection of X-ray has a linear correlation with surface LET across the photon energies of 8-12 keV. For a similar surface LET, the impinging heavy ion pushes the subcollector-substrate junction boundaries of the SiGe HBT deeper, resulting in higher charge collection. SEU screening of shift-registers show that X-ray can detect device sensitive nodes smaller than the beam.
- 30 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 81-90
New Approach for Pulsed-Laser Testing That Mimics Heavy-Ion Charge Deposition Profiles
- 30 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (1) , 81-90
New Approach for Pulsed-Laser Testing That Mimics Heavy-Ion Charge Deposition Profiles
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1682-1687
The Effect of the Gate-Connected Field Plate on Single-Event Transients in AlGaN/GaN Schottky-Gate HEMTs
focused pulsed X-ray beam is used to determine how the redistribution of the electric field by the gate-connected field plate affects single event transient (SET) susceptibility of an AlGaN/GaN Schottky-gate HEMT on SiC. SETs generated by scanning the X-ray beam across the HEMT depend strongly on the presence of the field plate, the radiation strike location, bias conditions, and X-ray photon energy. For the particular HEMT we tested, the gate-connected field plate reduces the electric field strength near the edge of the gate by a factor of approximately two, which results in faster decaying transients and less collected charge.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (7) , 1682-1687
The Effect of the Gate-Connected Field Plate on Single-Event Transients in AlGaN/GaN Schottky-Gate HEMTs
focused pulsed X-ray beam is used to determine how the redistribution of the electric field by the gate-connected field plate affects single event transient (SET) susceptibility of an AlGaN/GaN Schottky-gate HEMT on SiC. SETs generated by scanning the X-ray beam across the HEMT depend strongly on the presence of the field plate, the radiation strike location, bias conditions, and X-ray photon energy. For the particular HEMT we tested, the gate-connected field plate reduces the electric field strength near the edge of the gate by a factor of approximately two, which results in faster decaying transients and less collected charge.
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 368-375
Investigation of Single-Event Transients in AlGaN/GaN MIS-Gate HEMTs Using a Focused X-Ray Beam
Focused, pulsed X-rays are used to generate Single-Event Transients (SETs) in Metal-Insulator-Semiconductor (MIS)-gate AlGaN/GaN HEMTs in order to investigate the mechanisms responsible for the SETs. Unlike Schottky-gate GaN HEMTs, where current flows between gate and drain when the device is biased “off”, for the MIS-gate HEMTs current flows between the source and drain. The presence of the SiNx insulating layer under the gate effectively blocks electrons on the gate from moving into the semiconductor. Short-duration SETs at the gate are caused by the collection of holes injected by the X-rays. SETs collected at the source and drain have an initial short-duration component, followed by a long-duration tail that can last for hundreds of nanoseconds. The long tails are due to positive charges (holes) that are less mobile than the electrons and so take longer to exit the HEMT, and to holes that become trapped at defects in the material. The holes lower the potential barrier between the source and the region under the gate, allowing for the injection of electrons that flow from the source to the drain. The durations of the SET tails are determined by the lifetimes of the trapped holes that are found to vary with X-ray photon energy and electrical bias.
- 10 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (1) , 368-375
Investigation of Single-Event Transients in AlGaN/GaN MIS-Gate HEMTs Using a Focused X-Ray Beam
Focused, pulsed X-rays are used to generate Single-Event Transients (SETs) in Metal-Insulator-Semiconductor (MIS)-gate AlGaN/GaN HEMTs in order to investigate the mechanisms responsible for the SETs. Unlike Schottky-gate GaN HEMTs, where current flows between gate and drain when the device is biased “off”, for the MIS-gate HEMTs current flows between the source and drain. The presence of the SiNx insulating layer under the gate effectively blocks electrons on the gate from moving into the semiconductor. Short-duration SETs at the gate are caused by the collection of holes injected by the X-rays. SETs collected at the source and drain have an initial short-duration component, followed by a long-duration tail that can last for hundreds of nanoseconds. The long tails are due to positive charges (holes) that are less mobile than the electrons and so take longer to exit the HEMT, and to holes that become trapped at defects in the material. The holes lower the potential barrier between the source and the region under the gate, allowing for the injection of electrons that flow from the source to the drain. The durations of the SET tails are determined by the lifetimes of the trapped holes that are found to vary with X-ray photon energy and electrical bias.
- Open Access
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 478-485
Application of a Focused, Pulsed X-ray Beam for Total Ionizing Dose Testing of Bipolar Linear Integrated Circuits
We demonstrate the utility of focused, pulsed x-rays for investigating localized total ionizing dose effects in bipolar analog integrated circuits. Using the LM139 comparator as a test vehicle we show how the technique can be used to identify the sources of degradation as a result of irradiating different transistors of the device and how this impacts the input bias current, input offset voltage and output voltage. Two-dimensional mapping of the sensitive regions of transistors is presented where the results of localized irradiation impact the monitored operational parameters.
- 7 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 65 (1) , 478-485
Open AccessApplication of a Focused, Pulsed X-ray Beam for Total Ionizing Dose Testing of Bipolar Linear Integrated Circuits
We demonstrate the utility of focused, pulsed x-rays for investigating localized total ionizing dose effects in bipolar analog integrated circuits. Using the LM139 comparator as a test vehicle we show how the technique can be used to identify the sources of degradation as a result of irradiating different transistors of the device and how this impacts the input bias current, input offset voltage and output voltage. Two-dimensional mapping of the sensitive regions of transistors is presented where the results of localized irradiation impact the monitored operational parameters.