Daniele M. Monahan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniele M. Monahan has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Stephen D. LaLumondiere
The Aerospace Corporation, El Segundo, CA, USA
5 shared publications - Brett L. Ringel
Georgia Institute of Technology
3 shared publications - George N. Tzintzarov
The Aerospace Corporation, El Segundo, CA, USA
3 shared publications - Jeffrey W. Teng
The Aerospace Corporation, El Segundo, CA, USA
3 shared publications - John D. Cressler
Georgia Institute of Technology
3 shared publications - Ani Khachatrian
U.S. Naval Research Laboratory, Washington, DC, USA
2 shared publications
Latest Publications
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1172-1180
Total-Ionizing-Dose Effects in Integrated Silicon Phase Shifters Using Localized X-Ray Pulses
This study investigates the effects of total ionizing dose (TID) damage on silicon photonic (SiPh) phase shifters using Mach-Zehnder modulators (MZMs). By employing a microbeam X-ray source to irradiate one phase shifter in the MZM structure, we were able to isolate radiation-induced effects on phase shifter performance. The results demonstrate three key TID effects on the Si phase shifter: radiation-induced attenuation (RIA), radiation-induced refractive index change (RIRIC), and phase shifter pinch-off. Using the measured MZM transfer function, we developed formulations of radiation-induced effect, providing a quantitative tool for assessing how TID impacts SiPh modulator performance. Our findings suggest that multiple factors influence the variations in TID effects observed across different dose levels, including TID-induced changes to material structure, free carrier modulation, and band-to-band absorption due to radiation-induced defects. This study highlights the complexity of radiation effects in SiPh devices and provides insights that can guide future efforts to improve radiation tolerance in SiPh systems operating in extreme environments.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (4) , 1172-1180
Total-Ionizing-Dose Effects in Integrated Silicon Phase Shifters Using Localized X-Ray Pulses
This study investigates the effects of total ionizing dose (TID) damage on silicon photonic (SiPh) phase shifters using Mach-Zehnder modulators (MZMs). By employing a microbeam X-ray source to irradiate one phase shifter in the MZM structure, we were able to isolate radiation-induced effects on phase shifter performance. The results demonstrate three key TID effects on the Si phase shifter: radiation-induced attenuation (RIA), radiation-induced refractive index change (RIRIC), and phase shifter pinch-off. Using the measured MZM transfer function, we developed formulations of radiation-induced effect, providing a quantitative tool for assessing how TID impacts SiPh modulator performance. Our findings suggest that multiple factors influence the variations in TID effects observed across different dose levels, including TID-induced changes to material structure, free carrier modulation, and band-to-band absorption due to radiation-induced defects. This study highlights the complexity of radiation effects in SiPh devices and provides insights that can guide future efforts to improve radiation tolerance in SiPh systems operating in extreme environments.
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1798-1806
A Comparison of Total-Ionizing-Dose Effects in Silicon and Silicon-Nitride Waveguides
The total-ionizing-dose (TID) responses of silicon and low-loss silicon-nitride integrated waveguides are evaluated. Mach–Zehnder interferometers (MZIs), which allow for both TID-induced changes in effective refractive index ( neff ) and transmission losses to be observed, were exposed to 10-keV highly localized X-ray pulses facilitating very high dose irradiation for small exposure areas. TID-induced shifts in neff and transmission losses were observed for both waveguide types above 3 Mrad(Si), with the silicon waveguides exhibiting better radiation resilience for both metrics. Data collected was used to create Ansys-Lumerical simulations to propose potential mechanisms of TID-induced degradation in waveguides. Furthermore, to better understand the effects of neff degradation on other passive components, both silicon and silicon-nitride TID-damaged ring resonators were simulated in MATLAB. Differences in neff changes and transmission losses imply that for high dose environments (> 10 Mrad(Si)), when comparing waveguide types, silicon waveguides will provide similar loss performance and comparably smaller shifts in neff compared to typically lower-loss silicon-nitride waveguides.
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1798-1806
A Comparison of Total-Ionizing-Dose Effects in Silicon and Silicon-Nitride Waveguides
The total-ionizing-dose (TID) responses of silicon and low-loss silicon-nitride integrated waveguides are evaluated. Mach–Zehnder interferometers (MZIs), which allow for both TID-induced changes in effective refractive index ( neff ) and transmission losses to be observed, were exposed to 10-keV highly localized X-ray pulses facilitating very high dose irradiation for small exposure areas. TID-induced shifts in neff and transmission losses were observed for both waveguide types above 3 Mrad(Si), with the silicon waveguides exhibiting better radiation resilience for both metrics. Data collected was used to create Ansys-Lumerical simulations to propose potential mechanisms of TID-induced degradation in waveguides. Furthermore, to better understand the effects of neff degradation on other passive components, both silicon and silicon-nitride TID-damaged ring resonators were simulated in MATLAB. Differences in neff changes and transmission losses imply that for high dose environments (> 10 Mrad(Si)), when comparing waveguide types, silicon waveguides will provide similar loss performance and comparably smaller shifts in neff compared to typically lower-loss silicon-nitride waveguides.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 2116-2124
Direct Measurement of Total-Ionizing-Dose-Induced Phase Shifts in Commercially Available, Integrated Silicon-Photonic Waveguides
In this work, integrated silicon photonic waveguides are exposed to ionizing radiation. A micro-beam X-ray source was utilized to deliver an isolated dose to a waveguide that behaved as one branch of an integrated Mach-Zehnder interferometer (MZI) structure, such that any radiation-induced phase shifts can be directly measured. It is found that the silicon waveguides used in the present study exhibit a non-monotonic change in the effective index of refraction, neff , for both O-band and C-band operation due to radiation exposure. The neff first decreased with increasing dose, which is attributed to native SiO 2 growth in the silicon core. At larger doses, this trend reverses and the observed net change in neff eventually becomes positive. This increase in neff can most likely be attributed to radiation-induced densification of SiO 2 . Overall, it was found that these commercially-available silicon waveguides are sensitive to doses above 1×10 9 rad(Si), and the non-monotonic trends suggest that competing simultaneous mechanisms affect the waveguides under high dose levels.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 2116-2124
Direct Measurement of Total-Ionizing-Dose-Induced Phase Shifts in Commercially Available, Integrated Silicon-Photonic Waveguides
In this work, integrated silicon photonic waveguides are exposed to ionizing radiation. A micro-beam X-ray source was utilized to deliver an isolated dose to a waveguide that behaved as one branch of an integrated Mach-Zehnder interferometer (MZI) structure, such that any radiation-induced phase shifts can be directly measured. It is found that the silicon waveguides used in the present study exhibit a non-monotonic change in the effective index of refraction, neff , for both O-band and C-band operation due to radiation exposure. The neff first decreased with increasing dose, which is attributed to native SiO 2 growth in the silicon core. At larger doses, this trend reverses and the observed net change in neff eventually becomes positive. This increase in neff can most likely be attributed to radiation-induced densification of SiO 2 . Overall, it was found that these commercially-available silicon waveguides are sensitive to doses above 1×10 9 rad(Si), and the non-monotonic trends suggest that competing simultaneous mechanisms affect the waveguides under high dose levels.
- 11 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Non-Ionizing Radiation Effects on the Room Temperature Surface Recombination Velocity of Unintentionally Doped AlGaAs/GaAs Heterostructures
We used time resolved photoluminescence to extract surface recombination velocities and bulk carrier recombination lifetimes for a series of AlGaAs/GaAs heterostructures exposed to neutron radiation. While the measured exposure effects were dominated by the bulk, a statistically significant increase in the surface recombination velocity was observed for neutron fluences of and exceeding $1\times 10^{13}\ \mathrm{n}/\text{cm}^{2}$ . This result suggests that radiation effects on the surface recombination velocity become an important factor for modeling and qualification purposes when devices are exposed above a threshold fluence.- 11 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Non-Ionizing Radiation Effects on the Room Temperature Surface Recombination Velocity of Unintentionally Doped AlGaAs/GaAs Heterostructures
We used time resolved photoluminescence to extract surface recombination velocities and bulk carrier recombination lifetimes for a series of AlGaAs/GaAs heterostructures exposed to neutron radiation. While the measured exposure effects were dominated by the bulk, a statistically significant increase in the surface recombination velocity was observed for neutron fluences of and exceeding $1\times 10^{13}\ \mathrm{n}/\text{cm}^{2}$ . This result suggests that radiation effects on the surface recombination velocity become an important factor for modeling and qualification purposes when devices are exposed above a threshold fluence.- 18 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 626-633
Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting From Heavy-Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation
Heavy ion, focused X-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.
- 18 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 626-633
Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting From Heavy-Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation
Heavy ion, focused X-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. The transient shape characteristics depend on the source (ion, X-ray, or laser), even when similar amounts of charge are generated. The observed differences are examined and explained in terms of basic charge collection mechanisms.
- 6 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 617-625
Mapping the Spatial Dependence of Charge-Collection Efficiency in Semiconductor Devices Using Pulsed-Laser Testing
By scanning the charge-deposition profile produced by a pulsed laser throughout a device, the spatially dependent charge-collection efficiency (CCE) can be determined. This is demonstrated by extracting the depth-dependent CCE in two photodiodes. The resulting collection efficiency curves are found to be consistent with their device structures and the expected charge-collection mechanisms. By applying the efficiency curves to the charge-deposition curves for both heavy ions and pulsed X-rays, the calculated collected charge values show very good agreement with experimental results. This suggests that the profiles extracted using the laser can help predict charge-collection data from other excitation sources and could improve modeling efforts by determining sensitive volumes.
- 6 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (5) , 617-625
Mapping the Spatial Dependence of Charge-Collection Efficiency in Semiconductor Devices Using Pulsed-Laser Testing
By scanning the charge-deposition profile produced by a pulsed laser throughout a device, the spatially dependent charge-collection efficiency (CCE) can be determined. This is demonstrated by extracting the depth-dependent CCE in two photodiodes. The resulting collection efficiency curves are found to be consistent with their device structures and the expected charge-collection mechanisms. By applying the efficiency curves to the charge-deposition curves for both heavy ions and pulsed X-rays, the calculated collected charge values show very good agreement with experimental results. This suggests that the profiles extracted using the laser can help predict charge-collection data from other excitation sources and could improve modeling efforts by determining sensitive volumes.