Nebulized Albuterol Delivery in a Model of Spontaneously Breathing Children With Tracheostomy
Open Access
- 14 May 2013
- journal article
- research article
- Published by SAGE Publications in Respiratory Care
- Vol. 58 (12) , 2076-2086
Abstract
BACKGROUND: Nebulized therapy is commonly used in spontaneously breathing tracheostomized patients, despite a lack of recommended devices and techniques. I compared albuterol dose delivered to a model of spontaneously breathing children with tracheostomy, using different nebulizers, tracheostomy tube sizes, inhalation techniques, and breathing patterns. METHODS: A tracheostomy model was connected in series to a breathing simulator, with a filter interposed. I simulated the breathing patterns of a 16-month-old child and 12-year-old child, and tested tracheostomy tubes with internal diameters of 3.5 mm and 5.5 mm. Albuterol nebulizer solution (2.5 mg/3 mL) was used. A breath-enhanced nebulizer (Pari LC Plus), a breath-actuated nebulizer (AeroEclipse), and a nebulizer that continuously delivers aerosol (Up-Draft II Opti-Neb) were operated for 5 min at 6 L/min with wall air. The Up-Draft II was tested with T-piece and mask interfaces, with an extension tube, and with and without assisted breathing (every breath and every other breath). The amount of albuterol delivered was analyzed via spectrophotometry. Particle size distribution was measured with a cascade impactor. RESULTS: The Pari LC Plus was more efficient than the Up-Draft II or AeroEclipse. Assisted breathing with the Up-Draft II with extension increased albuterol delivery with every other breath (second best device/configuration), being superior to every breath technique. Adding an extension tube increased delivered albuterol. T-piece was more efficient than mask. Breathing patterns with larger tidal volume increased albuterol delivery. Tracheostomy size had less impact on drug delivery. Mass median aerodynamic diameter decreased by 48–74% when passing through the tracheostomy tubes, and 0.8% of the nominal dose was deposited in the tracheostomy tube. CONCLUSIONS: Albuterol delivery in a model of spontaneously breathing children with tracheostomy is influenced by type of device and configuration, use of assisted breathing, breathing pattern, and tracheostomy tube size. Mass median aerodynamic diameter significantly decreases during passage through a tracheostomy tube.Keywords
This publication has 22 references indexed in Scilit:
- Albuterol delivery via metered dose inhaler in a spontaneously breathing pediatric tracheostomy modelPediatric Pulmonology, 2012
- Optimization of a Procedure Used to Measure Aerosol Characteristics of Nebulized Solutions Using a Cooled Next Generation ImpactorJournal of Aerosol Medicine and Pulmonary Drug Delivery, 2010
- Effect of face mask dead volume, respiratory rate, and tidal volume on inhaled albuterol deliveryPediatric Pulmonology, 2010
- A modified spacer device for inhalational drug therapy for chronic bronchitis/asthma in laryngectomised patientsClinical Otolaryngology, 2000
- The use of inhalers in patients with tracheal stomas or tracheostomy tubes.The Journal of Laryngology & Otology, 1999
- An in vitro analysis of the output of salbutamol from different nebulizersEuropean Respiratory Journal, 1999
- Administration of inhaled medication via a tracheostomy in infants with chronic lung disease of prematurityPediatric Rehabilitation, 1999
- A homemade modification of a spacer device for delivery of bronchodilator or steroid therapy in patients with tracheostomies.The Journal of Laryngology & Otology, 1997
- Asthma therapy and a tracheostomyThe Journal of Laryngology & Otology, 1989
- The delivery of therapeutic aerosols through endotracheal tubesPediatric Pulmonology, 1986