A novel admittance-based pressure–volume system (AS) has recently been developed and introduced. Thus far, the new technique has been validated predominantly in small animals. In large animals it has only been compared to three-dimensional echocardiography (3DE) where the AS showed to overestimate left ventricular (LV) volumes. To fully determine the accuracy of this device, we compared the AS with gold standard cardiac magnetic resonance imaging (CMRI) in a porcine model of chronic myocardial infarction (MI). Fourteen pigs were subjected to 90 min closed chest balloon occlusion of the left anterior descending artery. After 8 weeks of follow up, pigs were consecutively subjected to LV volume measurements by the AS, CMRI, and 3DE under general anesthesia. The AS overestimated end diastolic volume (EDV; +20.9 ± 30.6 mL, P = 0.024) and end systolic volume (ESV; +17.7 ± 29.4 mL, P = 0.042) but not ejection fraction (EF; +2.46 ± 6.16%, P = NS) compared to CMRI. Good correlations of EDV (R = 0.626, P = 0.017) and EF (R = 0.704, P = 0.005) between the AS and CMRI were observed. EF measured by the AS and 3DE also correlated significantly (R = 0.624, P = 0.030). After subjection of pigs to MI, the AS very moderately overestimates LV volumes and shows accurate measurements for EF compared to CMRI. This makes the AS a useful tool to determine cardiac function and dynamic changes in large animal models of cardiac disease.Keywords
Funding Information
- BioMedical Materials institute
- Dutch Ministry of Economic Affairs
This publication has 28 references indexed in Scilit:
- Real Time Three‐Dimensional Echocardiographic Assessment of Left Ventricular Function in Heart Failure Patients: Underestimation of Left Ventricular Volume Increases with the Degree of DilatationEchocardiography, 2012
- Human relevance of pre-clinical studies in stem cell therapy: systematic review and meta-analysis of large animal models of ischaemic heart diseaseCardiovascular Research, 2011
- Measuring right ventricular function in the normal and hypertensive mouse hearts using admittance-derived pressure-volume loopsAmerican Journal of Physiology-Heart and Circulatory Physiology, 2010
- Validation of a New Micro-Manometer Pressure Sensor for Cardiovascular Measurements in MiceBiomedical Instrumentation & Technology, 2010
- Dynamic correction for parallel conductance, GP, and gain factor, α, in invasive murine left ventricular volume measurementsJournal of Applied Physiology, 2009
- Conductance, admittance, and hypertonic saline: should we take ventricular volume measurements with a grain of salt?Journal of Applied Physiology, 2009
- Left ventricular function in the post‐infarct failing mouse heart by magnetic resonance imaging and conductance catheter: a comparative analysisActa Physiologica, 2008
- A Comparison between QLAB and TomTec Full Volume Reconstruction for Real Time Three‐Dimensional Echocardiographic Quantification of Left Ventricular VolumesEchocardiography, 2007
- Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchersAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984