Malcolm White
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Malcolm White has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- John Lehman
National Institute of Standards and Technology, NIST
5 shared publications - Nathan A. Tomlin
National Institute of Standards and Technology, Boulder, CO 80305, United States of America
4 shared publications - Dave Harber
Laboratory for Atmospheric and Space Physics University of Colorado Boulder Boulder CO USA
3 shared publications - Michelle Stephens
National Institute of Standards and Technology, NIST
3 shared publications - Cameron Straatsma
Laboratory for Atmospheric and Space Physics, Boulder, CO 80303, United States of America
2 shared publications - Erik Richard
Laboratory for Atmospheric and Space Physics, Boulder, CO 80303, United States of America
2 shared publications
Latest Publications
- Open Access
- 8 September 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 055003
Optical fibre power metre calibration against cryogenic radiometers at telecom wavelengths
A study of optical fibre power metre calibrations is presented based on comparison with fibre-coupled cryogenic radiometry. Three nearly identical cryogenic radiometers are used together with a free-space absolute spectral responsivity measurement facility. The results show that the dominant sources of uncertainty originate not from the radiometers or the transfer standard detector, but from the optical path components used to convey light from the source to the detector. The properties of the optical radiation, defined by wavelength, polarization, and modal quality, together with system components such as optical fibres, fibre switches, fibre splitters, polarization controllers, and external influences including temperature and vibration, limit the achievable uncertainty. Measurements are performed at optical power levels near 100 µW, a regime in which the underlying measurement technology has matured over several decades. The absolute uncertainty ranges from approximately 0.0010 A W −1 to 0.0043 A W −1 , depending on the wavelength and components. The results provide a quantitative basis for assessing the limits of uncertainty reduction in fibre-based optical power measurements and are relevant to future uncertainty analyses of fibre-coupled single-photon detector efficiency in quantum communications and quantum technologies in general.
- 8 September 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (5) , 055003
Open AccessOptical fibre power metre calibration against cryogenic radiometers at telecom wavelengths
A study of optical fibre power metre calibrations is presented based on comparison with fibre-coupled cryogenic radiometry. Three nearly identical cryogenic radiometers are used together with a free-space absolute spectral responsivity measurement facility. The results show that the dominant sources of uncertainty originate not from the radiometers or the transfer standard detector, but from the optical path components used to convey light from the source to the detector. The properties of the optical radiation, defined by wavelength, polarization, and modal quality, together with system components such as optical fibres, fibre switches, fibre splitters, polarization controllers, and external influences including temperature and vibration, limit the achievable uncertainty. Measurements are performed at optical power levels near 100 µW, a regime in which the underlying measurement technology has matured over several decades. The absolute uncertainty ranges from approximately 0.0010 A W −1 to 0.0043 A W −1 , depending on the wavelength and components. The results provide a quantitative basis for assessing the limits of uncertainty reduction in fibre-based optical power measurements and are relevant to future uncertainty analyses of fibre-coupled single-photon detector efficiency in quantum communications and quantum technologies in general.
- Open Access
- 19 January 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (1)
Applying Heat Transport Modelling to Reduce Measurement Uncertainty of the LASP Reference Standard NACR8
Heat transport modelling of a planar absolute detector with vertically aligned carbon nanotube absorbers has been applied to the newly developed ambient-temperature electrical substitution radiometer (ESR), NACR8. Integrated into the Laboratory for Atmospheric and Space Physics (LASP) Total-solar-irradiance Radiometer Facility (TRF) NACR8 operates as an absolute optical power reference standard supporting validation of satellite based solar irradiance measurements, including those from the TSIS 2 TIM instrument. The modelling enables estimation and correction for electro-optical non-equivalence and its associated uncertainty, providing a generalised method applicable to planar thermal detectors. This approach represents an advancement in the understanding and correction of radiometric non-equivalence in optical radiation metrology. Traceability and performance of NACR8, incorporating a correction factor of 0.999562 with a standard uncertainty (u) = 0.000183 were confirmed through comparison with the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at 532.12 nm using a silicon photodiode light trapping transfer standard. Further comparison with NACR5, an established LASP optical power standard, showed agreement within stated uncertainties demonstrating the effectiveness of the heat transport modelling approach for addressing electro-optical non-equivalence in planar thermal detectors.
- 19 January 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (1)
Open AccessApplying Heat Transport Modelling to Reduce Measurement Uncertainty of the LASP Reference Standard NACR8
Heat transport modelling of a planar absolute detector with vertically aligned carbon nanotube absorbers has been applied to the newly developed ambient-temperature electrical substitution radiometer (ESR), NACR8. Integrated into the Laboratory for Atmospheric and Space Physics (LASP) Total-solar-irradiance Radiometer Facility (TRF) NACR8 operates as an absolute optical power reference standard supporting validation of satellite based solar irradiance measurements, including those from the TSIS 2 TIM instrument. The modelling enables estimation and correction for electro-optical non-equivalence and its associated uncertainty, providing a generalised method applicable to planar thermal detectors. This approach represents an advancement in the understanding and correction of radiometric non-equivalence in optical radiation metrology. Traceability and performance of NACR8, incorporating a correction factor of 0.999562 with a standard uncertainty (u) = 0.000183 were confirmed through comparison with the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at 532.12 nm using a silicon photodiode light trapping transfer standard. Further comparison with NACR5, an established LASP optical power standard, showed agreement within stated uncertainties demonstrating the effectiveness of the heat transport modelling approach for addressing electro-optical non-equivalence in planar thermal detectors.
- Open Access
- 8 April 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (2) , 025308
Application of voltage controlled crystal oscillators to DC voltage reference validation
DC voltage references are typically based on calibrated Zener Diodes which are subject to drift and therefore require periodic recalibration against a Primary Standard. Since it is preferable to maintain constant power to such references, the shipping and handling logistics involved in such a recalibration can present an unacceptable burden. Validation is therefore preferred, and typically accomplished by comparison against other local Zener Diodes. However, these Zener Diodes are all subject to correlated aging mechanisms. Voltage to frequency conversion represents an alternative mechanism for validation and accordingly, is not subject to aging highly correlated with the system being validated. Voltage to frequency conversion using a low space, weight, and power Voltage Controlled Oscillator offers a mechanism for identifying voltage reference drift by comparing the voltage-controlled frequency to primary frequency, typically available through GPS. This technique can validate voltage references when comparison against a primary voltage standard is impractical due to system deployment, away from a robust logistics chain. Voltage to frequency conversion may be accomplished by a Voltage Controlled Ovenized Crystal Oscillator. Using commercial-off-the-shelf hardware we constructed a test to evaluate the stability of such an oscillator for 258 days of continuous run-time, without age acceleration measures. Long-term drift was consistent with a t aging model. Sequestering 2/3 of the data to construct an aging model, then comparing sequestered data, yielded a model-to-data difference of 35 ppm (35 μV/V) which may prove acceptable in supporting instruments in the 6.5-digit voltmeter class.
- 8 April 2025
- Published by IOP Publishing in Engineering Research Express
- Vol. 7 (2) , 025308
Open AccessApplication of voltage controlled crystal oscillators to DC voltage reference validation
DC voltage references are typically based on calibrated Zener Diodes which are subject to drift and therefore require periodic recalibration against a Primary Standard. Since it is preferable to maintain constant power to such references, the shipping and handling logistics involved in such a recalibration can present an unacceptable burden. Validation is therefore preferred, and typically accomplished by comparison against other local Zener Diodes. However, these Zener Diodes are all subject to correlated aging mechanisms. Voltage to frequency conversion represents an alternative mechanism for validation and accordingly, is not subject to aging highly correlated with the system being validated. Voltage to frequency conversion using a low space, weight, and power Voltage Controlled Oscillator offers a mechanism for identifying voltage reference drift by comparing the voltage-controlled frequency to primary frequency, typically available through GPS. This technique can validate voltage references when comparison against a primary voltage standard is impractical due to system deployment, away from a robust logistics chain. Voltage to frequency conversion may be accomplished by a Voltage Controlled Ovenized Crystal Oscillator. Using commercial-off-the-shelf hardware we constructed a test to evaluate the stability of such an oscillator for 258 days of continuous run-time, without age acceleration measures. Long-term drift was consistent with a t aging model. Sequestering 2/3 of the data to construct an aging model, then comparing sequestered data, yielded a model-to-data difference of 35 ppm (35 μV/V) which may prove acceptable in supporting instruments in the 6.5-digit voltmeter class.
- Open Access
- 3 December 2024
- Published by IOP Publishing in Metrologia
- Vol. 62 (1) , 015002
High-fidelity analysis of the electro-optical non-equivalence of planar electrical substitution radiometers*
We present the results of a finite element analysis of the electro-optical non-equivalence of planar electrical substitution radiometers with vertically aligned carbon nanotube absorbers, operating at either room or cryogenic temperature. These detectors are the basis of the new room temperature standards of the Laboratory for Atmospheric and Space Physics’ (LASP) Total solar irradiance Radiometer Facility and the Spectral solar irradiance Radiometer Facility, and the NIST Boulder open beam cryogenic radiometer facility. We show that the detector of our cryogenic electrical substitution radiometer has no significant electro-optical non-equivalence. Further, we also show that with careful detector design, the non-equivalence can be minimized at room temperature. It was found that in general the non-equivalence cannot be deduced from the temperature mismatch between the electrical and the optical states without considering the conductance mismatch and optical power input. The results are regarded as being precise rather than absolute to account for potentially unknown modeling errors. The numerical accuracy is typically less than 5 ppm.
- 3 December 2024
- Published by IOP Publishing in Metrologia
- Vol. 62 (1) , 015002
Open AccessHigh-fidelity analysis of the electro-optical non-equivalence of planar electrical substitution radiometers*
We present the results of a finite element analysis of the electro-optical non-equivalence of planar electrical substitution radiometers with vertically aligned carbon nanotube absorbers, operating at either room or cryogenic temperature. These detectors are the basis of the new room temperature standards of the Laboratory for Atmospheric and Space Physics’ (LASP) Total solar irradiance Radiometer Facility and the Spectral solar irradiance Radiometer Facility, and the NIST Boulder open beam cryogenic radiometer facility. We show that the detector of our cryogenic electrical substitution radiometer has no significant electro-optical non-equivalence. Further, we also show that with careful detector design, the non-equivalence can be minimized at room temperature. It was found that in general the non-equivalence cannot be deduced from the temperature mismatch between the electrical and the optical states without considering the conductance mismatch and optical power input. The results are regarded as being precise rather than absolute to account for potentially unknown modeling errors. The numerical accuracy is typically less than 5 ppm.
- 26 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (5) , 054003
An assessment of the ageing of the absolute spectral responsivity of trap detectors at krypton ion laser emission wavelengths
We have assessed the absolute spectral responsivities of three-element trap detectors calibrated against the National Physical Laboratory primary standard cryogenic radiometer at eight krypton ion laser emission wavelengths over an approximate period of 20 years. As expected, we observed that the absolute spectral responsivities decrease with time. Additionally, we found that as the wavelength decreases, the ageing rate increases. At 356.4 nm, an average responsivity decrease of around −1800 ppm yr−1 is reported. While at longer wavelengths, the slowest rate of ageing, approximately −40 ppm yr−1, occurs at 799.3 nm. Interestingly, the year-on-year changes exhibit a relatively linear trend, allowing us to predict the future performance of the trap detectors. It is important to note, however, that predicted performance cannot be guaranteed and regular recalibration against a primary standard is essential, especially if low calibration uncertainties are required.
- 26 July 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (5) , 054003
An assessment of the ageing of the absolute spectral responsivity of trap detectors at krypton ion laser emission wavelengths
We have assessed the absolute spectral responsivities of three-element trap detectors calibrated against the National Physical Laboratory primary standard cryogenic radiometer at eight krypton ion laser emission wavelengths over an approximate period of 20 years. As expected, we observed that the absolute spectral responsivities decrease with time. Additionally, we found that as the wavelength decreases, the ageing rate increases. At 356.4 nm, an average responsivity decrease of around −1800 ppm yr−1 is reported. While at longer wavelengths, the slowest rate of ageing, approximately −40 ppm yr−1, occurs at 799.3 nm. Interestingly, the year-on-year changes exhibit a relatively linear trend, allowing us to predict the future performance of the trap detectors. It is important to note, however, that predicted performance cannot be guaranteed and regular recalibration against a primary standard is essential, especially if low calibration uncertainties are required.
- Open Access
- 24 June 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045002
Direct implementation of a frequency-programmable Josephson voltage standard to provide an SI traceable optical power scale
We have developed a technique to determine the electrical substitution power of a cryogenic optical radiant power detector, that directly implements a frequency-programmable Josephson voltage standard (FPJVS), thus reducing the traceability chain. The optical power detector and the Josephson voltage reference are combined inside a common cryogenic environment. We demonstrate the practicality of the technique by using a FPJVS to apply a known voltage across the resistive heater of a standard NIST cryogenic planar radiometric detector. The power applied to the detector heater is calculated from a measurement of the heater resistance and the known applied voltage. The FPJVS dc bias current source supplies dc current to the resistive heater. In this demonstration, the standard uncertainty of the substituted electrical power is limited by the uncertainty of the electrical heater four-wire resistance measurement at 4 K. The uncertainty due to the resistance measurement is 1 part in 105out of a total uncertainty of 1 part in 104(k= 2) on the 1 mW optical power measurement. We aim to develop the technique, to provide traceability to the International System of Units for the picowatt power measurement of single-photon emitters such as quantum dot sources.
- 24 June 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045002
Open AccessDirect implementation of a frequency-programmable Josephson voltage standard to provide an SI traceable optical power scale
We have developed a technique to determine the electrical substitution power of a cryogenic optical radiant power detector, that directly implements a frequency-programmable Josephson voltage standard (FPJVS), thus reducing the traceability chain. The optical power detector and the Josephson voltage reference are combined inside a common cryogenic environment. We demonstrate the practicality of the technique by using a FPJVS to apply a known voltage across the resistive heater of a standard NIST cryogenic planar radiometric detector. The power applied to the detector heater is calculated from a measurement of the heater resistance and the known applied voltage. The FPJVS dc bias current source supplies dc current to the resistive heater. In this demonstration, the standard uncertainty of the substituted electrical power is limited by the uncertainty of the electrical heater four-wire resistance measurement at 4 K. The uncertainty due to the resistance measurement is 1 part in 105out of a total uncertainty of 1 part in 104(k= 2) on the 1 mW optical power measurement. We aim to develop the technique, to provide traceability to the International System of Units for the picowatt power measurement of single-photon emitters such as quantum dot sources.
- Open Access
- 16 August 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065006
Decadal validation of the LASP TRF cryogenic radiometer by NIST, and establishment of a replacement room temperature standard*
We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.
- 16 August 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065006
Open AccessDecadal validation of the LASP TRF cryogenic radiometer by NIST, and establishment of a replacement room temperature standard*
We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.
- 17 June 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (4) , 044002
Generalized electrical substitution methods and detectors for absolute optical power measurements
We have developed generalized methods for electrical substitution optical measurements, as well as cryogenic detectors which can be used to implement them. The new methods detailed here enable measurement of arbitrary periodic waveforms by an electrical substitution radiometer (ESR), which means that spectral and dynamic optical power can be absolutely calibrated directly by a primary standard detector. Cryogenic ESRs are not often used directly by researchers for optical calibrations due to their slow response times and cumbersome operation. We describe two types of ESRs with fast response times, including newly developed cryogenic bolometers with carbon nanotube absorbers, which are manufacturable by standard microfabrication techniques. These detectors have response times near 10 ms, spectral coverage from the ultraviolet to far-infrared, and are ideal for use with generalized electrical substitution. In our first tests of the generalized electrical substitution method with FTS, we have achieved uncertainty in detector response of 0.13% (k = 1) and total measurement uncertainty of 1.1% (k = 1) in the mid-infrared for spectral detector responsivity calibrations. The generalized method and fast detectors greatly expand the range of optical power calibrations which can be made using a wideband primary standard detector, which can shorten calibration chains and improve uncertainties.
- 17 June 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (4) , 044002
Generalized electrical substitution methods and detectors for absolute optical power measurements
We have developed generalized methods for electrical substitution optical measurements, as well as cryogenic detectors which can be used to implement them. The new methods detailed here enable measurement of arbitrary periodic waveforms by an electrical substitution radiometer (ESR), which means that spectral and dynamic optical power can be absolutely calibrated directly by a primary standard detector. Cryogenic ESRs are not often used directly by researchers for optical calibrations due to their slow response times and cumbersome operation. We describe two types of ESRs with fast response times, including newly developed cryogenic bolometers with carbon nanotube absorbers, which are manufacturable by standard microfabrication techniques. These detectors have response times near 10 ms, spectral coverage from the ultraviolet to far-infrared, and are ideal for use with generalized electrical substitution. In our first tests of the generalized electrical substitution method with FTS, we have achieved uncertainty in detector response of 0.13% (k = 1) and total measurement uncertainty of 1.1% (k = 1) in the mid-infrared for spectral detector responsivity calibrations. The generalized method and fast detectors greatly expand the range of optical power calibrations which can be made using a wideband primary standard detector, which can shorten calibration chains and improve uncertainties.
- Open Access
- 17 August 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (5) , 706-715
Cryogenic primary standard for optical fibre power measurement
- 17 August 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (5) , 706-715
Open AccessCryogenic primary standard for optical fibre power measurement
- 10 August 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (5) , 699-705
A charge integrator amplifier and trap detector for pico-joule laser pulse energy measurement
We report the characterisation and calibration of a new laser pulse energy measurement device, developed for pico-joule pulse energy measurement at repetition rates up to 1 kHz. The device comprises a charge integration amplifier operating in conjunction with an input charge source; a light trapping photo-detector, which converts an incident laser pulse to a charge pulse. The novel amplifier individually integrates each charge pulse from the source and outputs a corresponding 20-bit resolution digital signal. This signal is converted to pulse energy through post processing, knowing the absolute responsivity of the photodiode detector and the calibration factors of the charge amplifier. A differential evolution algorithm is used to determine optimised values for the feedback capacitors of the amplifier, the amplifier gain and offset. The values measured by the new laser pulse energy meter were compared with those obtained from measurements traceable to both the high and low-level laser pulse energy scales maintained by NIST, Boulder. These were consistent within the combined expanded measurement uncertainty. This new device offers lower uncertainty and portability, suitable for field use.
- 10 August 2018
- Published by IOP Publishing in Metrologia
- Vol. 55 (5) , 699-705
A charge integrator amplifier and trap detector for pico-joule laser pulse energy measurement
We report the characterisation and calibration of a new laser pulse energy measurement device, developed for pico-joule pulse energy measurement at repetition rates up to 1 kHz. The device comprises a charge integration amplifier operating in conjunction with an input charge source; a light trapping photo-detector, which converts an incident laser pulse to a charge pulse. The novel amplifier individually integrates each charge pulse from the source and outputs a corresponding 20-bit resolution digital signal. This signal is converted to pulse energy through post processing, knowing the absolute responsivity of the photodiode detector and the calibration factors of the charge amplifier. A differential evolution algorithm is used to determine optimised values for the feedback capacitors of the amplifier, the amplifier gain and offset. The values measured by the new laser pulse energy meter were compared with those obtained from measurements traceable to both the high and low-level laser pulse energy scales maintained by NIST, Boulder. These were consistent within the combined expanded measurement uncertainty. This new device offers lower uncertainty and portability, suitable for field use.