High-resolution tomography of positron emitters with clustered pinhole SPECT
Open Access
- 4 February 2010
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (5) , 1265-1277
Abstract
State-of-the-art small-animal single photon emission computed tomography (SPECT) enables sub-half-mm resolution imaging of radio-labelled molecules. Due to severe photon penetration through pinhole edges, current multi-pinhole SPECT is not suitable for high-resolution imaging of photons with high energies, such as the annihilation photons emitted by positron emitting tracers (511 keV). To deal with this edge penetration, we introduce here clustered multi-pinhole SPECT (CMP): each pinhole in a cluster has a narrow opening angle to reduce photon penetration. Using simulations, CMP is compared with (i) a collimator with traditional pinholes that is currently used for sub-half-mm imaging of SPECT isotopes (U-SPECT-II), and (ii), like (i) but with collimator thickness adapted to image high-energy photons (traditional multi-pinhole SPECT, TMP). At 511 keV, U-SPECT-II is able to resolve the 0.9 mm rods of an iteratively reconstructed Jaszczak-like capillary hot rod phantom, and while TMP only leads to small improvements, CMP can resolve rods as small as 0.7 mm. Using a digital tumour phantom, we show that CMP resolves many details not assessable with standard USPECT-II and TMP collimators. Furthermore, CMP makes it possible to visualize uptake of positron emitting tracers in sub-compartments of a digital mouse striatal brain phantom. This may open up unique possibilities for analysing processes such as those underlying the function of neurotransmitter systems. Additional potential of CMP may include (i) the imaging of other high-energy single-photon emitters (e.g. I-131) and (ii) localized imaging of positron emitting tracers simultaneously with single photon emitters, with an even better resolution than coincidence PET.Keywords
This publication has 36 references indexed in Scilit:
- Bacterial Thymidine Kinase as a Non-Invasive Imaging Reporter for Mycobacterium tuberculosis in Live AnimalsPLOS ONE, 2009
- Preoperative 123I/99mTc-Sestamibi Subtraction SPECT and SPECT/CT in Primary HyperparathyroidismJournal of Nuclear Medicine, 2008
- Comparison of Simultaneous Dual-Isotope Multipinhole SPECT with Rotational SPECT in a Group of Patients with Coronary Artery DiseaseJournal of Nuclear Medicine, 2008
- Movies of dopamine transporter occupancy with ultra-high resolution focusing pinhole SPECTMolecular Psychiatry, 2007
- Comparison of [18F]FDOPA, [18F]FMT and [18F]FECNT for imaging dopaminergic neurotransmission in miceNuclear Medicine and Biology, 2006
- A multipinhole small animal SPECT system with submillimeter spatial resolutionMedical Physics, 2006
- Development of a 4-D digital mouse phantom for molecular imaging researchMolecular Imaging and Biology, 2004
- High-resolution SPECT using multipinhole collimationIEEE Transactions on Nuclear Science, 2003
- Uranium pinhole collimators for 511-keV photon SPECT imaging of small volumesIEEE Transactions on Nuclear Science, 2001
- Pinhole collimation for ultra-high-resolution, small-field-of-view SPECTPhysics in Medicine & Biology, 1994