Kuruchanvalasu Jambulingam Bharanitharan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kuruchanvalasu Jambulingam Bharanitharan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kuan-Lin Chen
Department of Mechanical and Electro-Mechanical Engineering, Tamkang University, New Taipei City 25137, Taiwan
1 shared publication - Kuan-Yu Luo
Department of Mechanical and Electro-Mechanical Engineering, Tamkang University, New Taipei City 25137, Taiwan
1 shared publication - Shung-Wen Kang
Department of Mechanical and Electro-Mechanical Engineering, Tamkang University, New Taipei City 25137, Taiwan
1 shared publication - Sundararaj Senthilkumar
Department of Aerospace Engineering, SRM Institute of Science and Technology, Kattankulathur, Chennai 603203, India
1 shared publication
Latest Publications
- Open Access
Correlations Based on Numerical Validation of Oscillating Flow Regenerator
Stirling regenerator is one of the emerging heat exchanger systems in the area of cryogenic cooling. Many kinds of research have been conducted to study the efficiency of Stirling regenerators. Therefore, the principles and related knowledge of Stirling refrigerators must be thoroughly understood to design a regenerator with excellent performance for low-temperature and cryogenic engineering applications. In this study, an experimental setup is developed to estimate the pressure drop of the oscillating flow through two different wire-mesh regenerators, namely, 200 mesh and 300 mesh, for various operating frequencies ranging from 3 (200 RPM) to 10 Hz (600 RPM). Transient, axisymmetric, incompressible, and laminar flow governing equations are solved numerically, and source terms are added in the governing equations with the help of the porous media model and the Ergun semiempirical correlation, assuming that the wire meshes are cylindrical particles arranged uniformly. Simulation results show that the numerical predictions of temporal pressure variation are in reasonably good agreement with those of experimental findings. It is also found that the Ergun correlation works more accurately for higher flow rate conditions.
Open AccessCorrelations Based on Numerical Validation of Oscillating Flow Regenerator
Stirling regenerator is one of the emerging heat exchanger systems in the area of cryogenic cooling. Many kinds of research have been conducted to study the efficiency of Stirling regenerators. Therefore, the principles and related knowledge of Stirling refrigerators must be thoroughly understood to design a regenerator with excellent performance for low-temperature and cryogenic engineering applications. In this study, an experimental setup is developed to estimate the pressure drop of the oscillating flow through two different wire-mesh regenerators, namely, 200 mesh and 300 mesh, for various operating frequencies ranging from 3 (200 RPM) to 10 Hz (600 RPM). Transient, axisymmetric, incompressible, and laminar flow governing equations are solved numerically, and source terms are added in the governing equations with the help of the porous media model and the Ergun semiempirical correlation, assuming that the wire meshes are cylindrical particles arranged uniformly. Simulation results show that the numerical predictions of temporal pressure variation are in reasonably good agreement with those of experimental findings. It is also found that the Ergun correlation works more accurately for higher flow rate conditions.