ACAndrew J. Coristine

Andrew J. Coristine

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew J. Coristine has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improved respiratory self‐navigation for 3D radial acquisitions through the use of a pencil‐beam 2D‐T2‐prep for free‐breathing, whole‐heart coronary MRA

    by Andrew J. Coristine, Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud B. van Heeswijk, Davide Piccini, Matthias Stuber

    Purpose: In respiratory self‐navigation (SN), signal from static structures, such as the chest wall, may complicate motion detection or introduce post‐correction artefacts. Suppressing signal from superfluous tissues may therefore improve image quality. We thus test the hypothesis that SN whole‐heart coronary magnetic resonance angiography (MRA) will benefit from an outer‐volume suppressing 2D‐T2‐Prep and present both phantom and in vivo results.Methods: A 2D‐T2‐Prep and a conventional T2‐Prep were used prior to a free‐breathing 3D‐radial SN sequence. Both techniques were compared by imaging a home‐built moving cardiac phantom and by performing coronary MRA in nine healthy volunteers. Reconstructions were performed using both a reference‐based and a reference‐independent approach to motion tracking, along with several coil combinations. Signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were compared, along with vessel sharpness (VS).Results: In phantoms, using the 2D‐T2‐Prep increased SNR by 16% to 53% and mean VS by 8%; improved motion tracking precision was also achieved. In volunteers, SNR increased by an average of 29% to 33% in the blood pool and by 15% to 25% in the myocardium, depending on the choice of reconstruction coils and algorithm, and VS increased by 34%.Conclusion: A 2D‐T2‐Prep significantly improves image quality in both phantoms and volunteers when performing SN coronary MRA. Magn Reson Med 79:1293–1303, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


  • Open Access

    A Cylindrical, Inner Volume Selecting 2D-T2-Prep Improves GRAPPA-Accelerated Image Quality in MRA of the Right Coronary Artery

    by Andrew J. Coristine, Jerome Yerly, Matthias Stuber

    Two-dimensional (2D) spatially selective radiofrequency (RF) pulses may be used to excite restricted volumes. By incorporating a "pencil beam" 2D pulse into a T2-Prep, one may create a "2D-T2-Prep" that combines T2-weighting with an intrinsic outer volume suppression. This may particularly benefit parallel imaging techniques, where artefacts typically originate from residual foldover signal. By suppressing foldover signal with a 2D-T2-Prep, image quality may therefore improve. We present numerical simulations, phantom and in vivo validations to address this hypothesis. A 2D-T2-Prep and a conventional T2-Prep were used with GRAPPA-accelerated MRI (R = 1.6). The techniques were first compared in numerical phantoms, where per pixel maps of SNR (SNRmulti), noise, and g-factor were predicted for idealized sequences. Physical phantoms, with compartments doped to mimic blood, myocardium, fat, and coronary vasculature, were scanned with both T2-Preparation techniques to determine the actual SNRmulti and vessel sharpness. For in vivo experiments, the right coronary artery (RCA) was imaged in 10 healthy adults, using accelerations of R = 1,3, and 6, and vessel sharpness was measured for each. In both simulations and phantom experiments, the 2D-T2-Prep improved SNR relative to the conventional T2-Prep, by an amount that depended on both the acceleration factor and the degree of outer volume suppression. For in vivo images of the RCA, vessel sharpness improved most at higher acceleration factors, demonstrating that the 2D-T2-Prep especially benefits accelerated coronary MRA. Suppressing outer volume signal with a 2D-T2-Prep improves image quality particularly well in GRAPPA-accelerated acquisitions in simulations, phantoms, and volunteers, demonstrating that it should be considered when performing accelerated coronary MRA.


  • Open Access

    Fat signal suppression for coronary MRA at 3T using a water‐selective adiabatic T2‐preparation technique

    by Andrew J. Coristine, Ruud B. van Heeswijk, Matthias Stuber