JWJunwei Wang

Junwei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junwei Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental study on axial compression performance of mortise-and-tenon precast concrete beam–column joints

    by Cheng Zhang, Wenxue Zhang, Junwei Wang, Lijun Su

    Mortise-and-tenon precast concrete (MTPC) beam–column joints utilize a mortise–tenon structure with longitudinal prestressing to secure their connections. This approach offers advantages such as dry construction, easy assembly, a short construction period, and the possibility of disassembly. To meet the “strong joint” requirement, this study enhances the core areas of the joints through ultra-high–performance concrete (UHPC) reinforcement and rebar enhancement. First, the structure and assembly method for MTPC joints are introduced. Subsequently, five distinct specimens are fabricated for testing: two UHPC-reinforced models, one rebar-enhanced model, one standard MTPC joint model, and one cast-in-place joint model. All specimens are then subjected to monotonic axial compression tests. The results show that the optimized MTPC joints exhibit significantly improved axial compressive strength, reaching 90% to 100% of the capacity of the cast-in-place joint. With regard to the optimization methods, whereas increasing rebar ratios enhances axial strength, it does not fully achieve the “strong joint” criterion. By contrast, UHPC reinforcement significantly boosts axial compressive capacity, achieving the desired “strong joint” standard. After axial load is used to compact the assembly gaps in MTPC joints, the overall integrity is made strong, axial stiffness remains stable, and the load transfer path becomes clear. With UHPC reinforcement, force transmission through the MTPC joint components becomes more reliable, with the tenon bearing more axial load; however, the tenon should not be used as the main vertical force transmission section. Finally, it is found that the axial compressive load capacity calculation method recommended by the Chinese code can accurately and safely predict the axial compressive load capacities of MTPC joints.

  • Experimental Investigation and Calculation Method on Axial Compression Properties of Unbonded Prestressed Mortise–Tenon Precast Concrete Mid Joint

    by Cheng Zhang, Wenxue Zhang, Junwei Wang, Xiuli Du, Lijun Su

    This study examines the axial compression performance of unbonded prestressed mortise–tenon beam–column joints (MTPC). The MTPC joint employs a mortise–tenon configuration, achieving tight compression through unbonded prestressed steel strands at the column's center, enhancing prefabrication efficiency. Three axial compression test models were fabricated and subjected to axial monotonic loading, with experimental phenomena and results analyzed. The results show the optimized MTPC joint achieves approximately 90% of the column‐end axial capacity, while MTPC joints reinforced with ultra‐high‐performance concrete (UHPC) surpass the column‐end capacity, fulfilling the “strong joints, weak components” design principle. Minor gaps during assembly require axial pressure for tight component contact, but the assembled joint demonstrates excellent integrity, stable axial stiffness, and effective load transfer. A calculation method for the axial load‐bearing capacity of MTPC joints is proposed, along with a finite element model. Comparison with experimental results validates the model's accuracy. Theoretical calculations, experimental data, and finite element analysis collectively confirm the proposed method effectively predicts the axial compression capacity and mechanical behavior of MTPC joints under axial loading. This research highlights the MTPC joint's potential for enhancing construction efficiency and structural performance in prefabricated systems.

  • Seismic performance analysis of the prestressed prefabricated concrete frame structure with mortise-tendon joints

    by Junwei Wang, Cheng Zhang, Wenxue Zhang, Zhenbao Li

    In this paper, a novel assembled concrete frame structure (Prestressed Mortise and Tenon Frame, PMTF) was proposed. The PMTF utilizes a combination of prestressed and mortise-tenon connections. The core zone of the joints in the PMTF involves the upper column tenon, integrating the slab-beam connection zone, and incorporating the lower column cups to create a mortise-tenon connection, similar to those found in timber structures. To ensure reliable connection between each component of the core zone, the unbonded prestressing strands (UPS) were applied. The UPS serves to provide the restoring force and reduce the residual deformation at the same time. To further investigated its seismic performance, One-story, two-span finite element model (FEM) of the PMTF was established using the FEM software ABAQUS. Firstly, the damage process and modes of the PMTF were analyzed under two different horizontal loading conditions: monotonic and low-cycle reciprocating loading. Secondly, the parametric analysis of the PMTF was carried out with four parameters: axial compression ratio, prestressing tendon area and initial effective stress of the UPS, and contact friction coefficient of concrete interface. Finally, a restoring force model of the PMTF was proposed. The results showed that the PMTF exhibited the moderate energy dissipation capacity and relatively small residual deformation, with damaged localized primarily in the core zone of the joints. The axial compression ratio had a more significant effect on the hysteretic performance of PMTF compared to the other parameters. The suggested values for each parameter were as follows: axial compression ratio less than 0.3, initial effective stress less than 0.75 f pu , and friction coefficient between 0.6 and 0.7. The proposed restoring force model can effectively predict the hysteretic performance of the PMTF.