Accurate methane emission quantification is critical for climate mitigation efforts in the oil and gas industry. This study evaluates the performance of five academic methane measurement systems through single-blind controlled release testing at the TotalEnergies Anomaly Detection Initiatives (TADI) facility in France during June and September 2024. Vehicle-based teams from Technical University of Denmark, Heidelberg University, and a collaborative team from Utrecht University/LSCE/Cyprus Institute/Royal Holloway deployed mobile in situ measurement systems, while aircraft-based solutions from Empa/UZH and FAAM BAe-146 utilized hyperspectral imaging and airborne in situ measurements, respectively. Vehicle-based systems demonstrated strong detection capabilities with true positive rates of 93–100 % and minimum detection thresholds below 1 kg CH₄ h⁻¹. Quantification accuracy varied significantly, with slopes ranging from 0.38 to 1.04 when comparing estimated versus true emission rates. Aircraft systems showed more variable performance due to operational constraints and limited data availability. Post-unblinding analysis revealed critical insights into systematic errors, including background concentration calculation issues and wind measurement limitations. Low wind conditions (<2 m s⁻¹) particularly challenged quantification accuracy across all platforms. These findings highlight the importance of robust validation procedures and high-quality meteorological data for reliable methane emission quantification in real-world applications.