Philippine Burdeau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Philippine Burdeau has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Adam R. Brandt
Department of Energy Science & Engineering, Stanford University, Stanford, CA 94305, USA
10 shared publications- Audrey McManemin
Department of Energy Science & Engineering, Stanford University, Stanford, CA 94305, USA
9 shared publications Catherine Juéry
Air Quality Laboratory, TotalEnergies, 69360 Solaize, France
9 shared publications- James Lawrence France
Earth Sciences Department, Royal Holloway University of London, Egham, Surrey TW20 0EX, UK
9 shared publications Vincent Blandin
TotalEnergies Anomaly Detection Initiatives, TotalEnergies, 64170 Lacq, France
9 shared publicationsAnders M. Fredenslund
Department of Environmental and Resource Engineering, Technical University of Denmark, Denmark
4 shared publications
Latest Publications
- Open Access
- 11 September 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-32
Comment on egusphere-2026-1744
Accurate methane emission quantification is critical for climate mitigation efforts in the oil and gas industry. This study evaluates the performance of five academic methane measurement systems through single-blind controlled release testing at the TotalEnergies Anomaly Detection Initiatives (TADI) facility in France during June and September 2024. Vehicle-based teams from Technical University of Denmark, Heidelberg University, and a collaborative team from Utrecht University/LSCE/Cyprus Institute/Royal Holloway deployed mobile in situ measurement systems, while aircraft-based solutions from Empa/UZH and FAAM BAe-146 utilized hyperspectral imaging and airborne in situ measurements, respectively. Vehicle-based systems demonstrated strong detection capabilities with true positive rates of 93–100 % and minimum detection thresholds below 1 kg CH₄ h⁻¹. Quantification accuracy varied significantly, with slopes ranging from 0.38 to 1.04 when comparing estimated versus true emission rates. Aircraft systems showed more variable performance due to operational constraints and limited data availability. Post-unblinding analysis revealed critical insights into systematic errors, including background concentration calculation issues and wind measurement limitations. Low wind conditions (<2 m s⁻¹) particularly challenged quantification accuracy across all platforms. These findings highlight the importance of robust validation procedures and high-quality meteorological data for reliable methane emission quantification in real-world applications.
- 11 September 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-32
Open AccessComment on egusphere-2026-1744
Accurate methane emission quantification is critical for climate mitigation efforts in the oil and gas industry. This study evaluates the performance of five academic methane measurement systems through single-blind controlled release testing at the TotalEnergies Anomaly Detection Initiatives (TADI) facility in France during June and September 2024. Vehicle-based teams from Technical University of Denmark, Heidelberg University, and a collaborative team from Utrecht University/LSCE/Cyprus Institute/Royal Holloway deployed mobile in situ measurement systems, while aircraft-based solutions from Empa/UZH and FAAM BAe-146 utilized hyperspectral imaging and airborne in situ measurements, respectively. Vehicle-based systems demonstrated strong detection capabilities with true positive rates of 93–100 % and minimum detection thresholds below 1 kg CH₄ h⁻¹. Quantification accuracy varied significantly, with slopes ranging from 0.38 to 1.04 when comparing estimated versus true emission rates. Aircraft systems showed more variable performance due to operational constraints and limited data availability. Post-unblinding analysis revealed critical insights into systematic errors, including background concentration calculation issues and wind measurement limitations. Low wind conditions (<2 m s⁻¹) particularly challenged quantification accuracy across all platforms. These findings highlight the importance of robust validation procedures and high-quality meteorological data for reliable methane emission quantification in real-world applications.
- Open Access
- 3 August 2026
- Published by Copernicus GmbH
- p. 1-32
Comment on egusphere-2026-1744
Accurate methane emission quantification is critical for climate mitigation efforts in the oil and gas industry. This study evaluates the performance of five academic methane measurement systems through single-blind controlled release testing at the TotalEnergies Anomaly Detection Initiatives (TADI) facility in France during June and September 2024. Vehicle-based teams from Technical University of Denmark, Heidelberg University, and a collaborative team from Utrecht University/LSCE/Cyprus Institute/Royal Holloway deployed mobile in situ measurement systems, while aircraft-based solutions from Empa/UZH and FAAM BAe-146 utilized hyperspectral imaging and airborne in situ measurements, respectively. Vehicle-based systems demonstrated strong detection capabilities with true positive rates of 93–100 % and minimum detection thresholds below 1 kg CH₄ h⁻¹. Quantification accuracy varied significantly, with slopes ranging from 0.38 to 1.04 when comparing estimated versus true emission rates. Aircraft systems showed more variable performance due to operational constraints and limited data availability. Post-unblinding analysis revealed critical insights into systematic errors, including background concentration calculation issues and wind measurement limitations. Low wind conditions (<2 m s⁻¹) particularly challenged quantification accuracy across all platforms. These findings highlight the importance of robust validation procedures and high-quality meteorological data for reliable methane emission quantification in real-world applications.
- 3 August 2026
- Published by Copernicus GmbH
- p. 1-32
Open AccessComment on egusphere-2026-1744
Accurate methane emission quantification is critical for climate mitigation efforts in the oil and gas industry. This study evaluates the performance of five academic methane measurement systems through single-blind controlled release testing at the TotalEnergies Anomaly Detection Initiatives (TADI) facility in France during June and September 2024. Vehicle-based teams from Technical University of Denmark, Heidelberg University, and a collaborative team from Utrecht University/LSCE/Cyprus Institute/Royal Holloway deployed mobile in situ measurement systems, while aircraft-based solutions from Empa/UZH and FAAM BAe-146 utilized hyperspectral imaging and airborne in situ measurements, respectively. Vehicle-based systems demonstrated strong detection capabilities with true positive rates of 93–100 % and minimum detection thresholds below 1 kg CH₄ h⁻¹. Quantification accuracy varied significantly, with slopes ranging from 0.38 to 1.04 when comparing estimated versus true emission rates. Aircraft systems showed more variable performance due to operational constraints and limited data availability. Post-unblinding analysis revealed critical insights into systematic errors, including background concentration calculation issues and wind measurement limitations. Low wind conditions (<2 m s⁻¹) particularly challenged quantification accuracy across all platforms. These findings highlight the importance of robust validation procedures and high-quality meteorological data for reliable methane emission quantification in real-world applications.
- Open Access
- 14 July 2026
- Published by Copernicus GmbH
Supplementary material to "From research to reality: Academic methane measurement systems tested at the TADI controlled release facility"
- 14 July 2026
- Published by Copernicus GmbH
Open AccessSupplementary material to "From research to reality: Academic methane measurement systems tested at the TADI controlled release facility"
- Open Access
- 14 July 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-32
From research to reality: Academic methane measurement systems tested at the TADI controlled release facility
Accurate methane emission quantification is critical for climate mitigation efforts in the oil and gas industry. This study evaluates the performance of five academic methane measurement systems through single-blind controlled release testing at the TotalEnergies Anomaly Detection Initiatives (TADI) facility in France during June and September 2024. Vehicle-based teams from Technical University of Denmark, Heidelberg University, and a collaborative team from Utrecht University/LSCE/Cyprus Institute/Royal Holloway deployed mobile in situ measurement systems, while aircraft-based solutions from Empa/UZH and FAAM BAe-146 utilized hyperspectral imaging and airborne in situ measurements, respectively. Vehicle-based systems demonstrated strong detection capabilities with true positive rates of 93–100 % and minimum detection thresholds below 1 kg CH₄ h⁻¹. Quantification accuracy varied significantly, with slopes ranging from 0.38 to 1.04 when comparing estimated versus true emission rates. Aircraft systems showed more variable performance due to operational constraints and limited data availability. Post-unblinding analysis revealed critical insights into systematic errors, including background concentration calculation issues and wind measurement limitations. Low wind conditions (<2 m s⁻¹) particularly challenged quantification accuracy across all platforms. These findings highlight the importance of robust validation procedures and high-quality meteorological data for reliable methane emission quantification in real-world applications.
- 14 July 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-32
Open AccessFrom research to reality: Academic methane measurement systems tested at the TADI controlled release facility
Accurate methane emission quantification is critical for climate mitigation efforts in the oil and gas industry. This study evaluates the performance of five academic methane measurement systems through single-blind controlled release testing at the TotalEnergies Anomaly Detection Initiatives (TADI) facility in France during June and September 2024. Vehicle-based teams from Technical University of Denmark, Heidelberg University, and a collaborative team from Utrecht University/LSCE/Cyprus Institute/Royal Holloway deployed mobile in situ measurement systems, while aircraft-based solutions from Empa/UZH and FAAM BAe-146 utilized hyperspectral imaging and airborne in situ measurements, respectively. Vehicle-based systems demonstrated strong detection capabilities with true positive rates of 93–100 % and minimum detection thresholds below 1 kg CH₄ h⁻¹. Quantification accuracy varied significantly, with slopes ranging from 0.38 to 1.04 when comparing estimated versus true emission rates. Aircraft systems showed more variable performance due to operational constraints and limited data availability. Post-unblinding analysis revealed critical insights into systematic errors, including background concentration calculation issues and wind measurement limitations. Low wind conditions (<2 m s⁻¹) particularly challenged quantification accuracy across all platforms. These findings highlight the importance of robust validation procedures and high-quality meteorological data for reliable methane emission quantification in real-world applications.
- Open Access
- 10 February 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (3) , 923-934
Controlled release testing of commercially available methane emission measurement technologies at the TADI facility
This study presents an independent and blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R2. False positive detection rates ranged from 0 % to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.
- 10 February 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (3) , 923-934
Open AccessControlled release testing of commercially available methane emission measurement technologies at the TADI facility
This study presents an independent and blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R2. False positive detection rates ranged from 0 % to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.
- Open Access
- 19 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-21
Reply on RC1 and RC2
This study presents the first public, academic, blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R². False positive detection rates ranged from 0 to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.
- 19 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-21
Open AccessReply on RC1 and RC2
This study presents the first public, academic, blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R². False positive detection rates ranged from 0 to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.
- Open Access
- 27 November 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-21
Comment on egusphere-2025-3793
This study presents the first public, academic, blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R². False positive detection rates ranged from 0 to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.
- 27 November 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-21
Open AccessComment on egusphere-2025-3793
This study presents the first public, academic, blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R². False positive detection rates ranged from 0 to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.
- Open Access
- 21 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1)
High-resolution national mapping of natural gas composition substantially updates methane leakage impacts
Methane is emitted from oil and gas operations alongside heavier hydrocarbons and non-hydrocarbon gases, shaping emissions management decision-making, including air quality impacts. Yet, most assessments assume fixed gas composition, overlooking significant spatial and temporal variations. Here, we generate a high-resolution, data-driven map of natural gas composition across the United States, reconstructing methane, heavier hydrocarbons, and non-hydrocarbon species using spatio-temporal interpolation and oil-and-gas production patterns. Our approach is able to reduce composition prediction errors by 39% in terms of Mean Absolute Error (MAE) compared to standard techniques and reveals that methane loss rates have been underestimated by more than 50% in some regions. Beyond methane, we uncover substantial variability in co-emitted gases, exposing blind spots in current emissions inventories and emissions management frameworks. Our work enables more accurate emissions assessments, guides targeted measurement strategies, and informs emissions management decision-making. It also provides a general framework for prediction in environmental applications that integrate sparse measurements with auxiliary variables.
- 21 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1)
Open AccessHigh-resolution national mapping of natural gas composition substantially updates methane leakage impacts
Methane is emitted from oil and gas operations alongside heavier hydrocarbons and non-hydrocarbon gases, shaping emissions management decision-making, including air quality impacts. Yet, most assessments assume fixed gas composition, overlooking significant spatial and temporal variations. Here, we generate a high-resolution, data-driven map of natural gas composition across the United States, reconstructing methane, heavier hydrocarbons, and non-hydrocarbon species using spatio-temporal interpolation and oil-and-gas production patterns. Our approach is able to reduce composition prediction errors by 39% in terms of Mean Absolute Error (MAE) compared to standard techniques and reveals that methane loss rates have been underestimated by more than 50% in some regions. Beyond methane, we uncover substantial variability in co-emitted gases, exposing blind spots in current emissions inventories and emissions management frameworks. Our work enables more accurate emissions assessments, guides targeted measurement strategies, and informs emissions management decision-making. It also provides a general framework for prediction in environmental applications that integrate sparse measurements with auxiliary variables.
- Open Access
- 2 September 2025
- Published by Copernicus GmbH
Supplementary material to "Controlled release testing of commercially available methane emission measurement technologies at the TADI facility"
- 2 September 2025
- Published by Copernicus GmbH
Open AccessSupplementary material to "Controlled release testing of commercially available methane emission measurement technologies at the TADI facility"
- Open Access
- 2 September 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-21
Controlled release testing of commercially available methane emission measurement technologies at the TADI facility
This study presents the first public, academic, blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R². False positive detection rates ranged from 0 to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.
- 2 September 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-21
Open AccessControlled release testing of commercially available methane emission measurement technologies at the TADI facility
This study presents the first public, academic, blinded controlled release evaluation of methane detection and quantification technologies in Europe. Conducted at the TotalEnergies Anomalies Detection Initiatives (TADI) site in France, the campaign tested eight commercial systems – including satellite, drone, and continuous monitoring platforms – under controlled single-blind conditions. Participants submitted methane emission rate estimates without prior knowledge of true release values. Performance was assessed through detection limit curves, parity plots, and statistical metrics including slope and R². False positive detection rates ranged from 0 to 11 %. Quantification slopes ranged from 0.09 to 1.13, with a trend toward underestimation, and R2 values ranged from 0.08 to 0.97. Wind conditions – particularly low speeds and high variability – were a key factor affecting quantification accuracy, emphasizing the need for high-quality wind data integration. This study underscores the importance of rigorous, standardized testing to benchmark technology performance and inform regulatory efforts. Results highlight platform-specific strengths and challenges, providing actionable insights for participants, policymakers, and regulators. These findings support the development of robust, validated methane measurement tools critical to achieving effective emissions monitoring and reduction strategies under evolving regulatory frameworks, such as those in the European Union.