Abstract
A pair of walking phantoms was developed from deformable mesh phantoms to represent individuals walking on contaminated ground. The Monte Carlo N-particle extended version code was used to calculate organ doses from ground contamination scenarios involving parallel and isotropic planar sources of Cs-137 and Co-60 with concentrations of 30 kBqm−2. For the parallel plane source case, the organ doses were up to 78 % greater for walking phantoms than those for the standing phantoms. The dose difference is because the widely open legs during walking provide less shielding to several organs, especially the kidneys, ovaries and liver, from parallel sources. The effective doses of the walking phantoms were on average 15 % higher than the standing phantoms. On the other hand, when isotropic planar sources were considered, no significant dose difference was observed. This study demonstrated the feasibility of using deformable phantoms to represent realistic postures for organ dose calculations in environmental dosimetry studies.Keywords
This publication has 11 references indexed in Scilit:
- RPI-AM and RPI-AF, a pair of mesh-based, size-adjustable adult male and female computational phantoms using ICRP-89 parameters and their calculations for organ doses from monoenergetic photon beamsPhysics in Medicine & Biology, 2009
- A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9Physics in Medicine & Biology, 2007
- Computational Anthropomorphic Models of the Human Anatomy: The Path to Realistic Monte Carlo Modeling in Radiological SciencesAnnual Review of Biomedical Engineering, 2007
- An Investigation of Voxel Geometries for MCNP-based Radiation Dose CalculationsHealth Physics, 2006
- Simplification and repair of polygonal models using volumetric techniquesIEEE Transactions on Visualization and Computer Graphics, 2003
- Current contamination by 137Cs and 90Sr of the inhabited part of the Techa river basin in the UralsJournal of Environmental Radioactivity, 2002
- Comparisons between MCNP, EGS4 and experiment for clinical electron beamsPhysics in Medicine & Biology, 1999
- Modifications to the ORNL Phantom Series in Simulation of the Responses of Thyroid DetectorsRadiation Protection Dosimetry, 1998
- Basic anatomical and physiological data for use in radiological protection: the skeleton. A report of a Task Group of Committee 2 of the International Commission on Radiological Protection.1995
- Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom.1969