Improving the analyte ion signal in matrix‐assisted laser desorption/ionization imaging mass spectrometry via electrospray deposition by enhancing incorporation of the analyte in the matrix
- 2 April 2017
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 31 (9) , 804-812
Abstract
Rationale: Matrix‐assisted laser desorption/ionization (MALDI) is widely used as the ionization method in high‐resolution chemical imaging studies that seek to visualize the distribution of analytes within sectioned biological tissues. This work extends the use of electrospray deposition (ESD) to apply matrix with an additional solvent spray to incorporate and homogenize analyte within the matrix overlayer. Methods: Analytes and matrix are sequentially and independently applied by ESD to create a sample from which spectra are collected, mimicking a MALDI imaging mass spectrometry (IMS) experiment. Subsequently, an incorporation spray consisting of methanol is applied by ESD to the sample and another set of spectra are collected. The spectra prior to and after the incorporation spray are compared to evaluate the improvement in the analyte signal. Results: Prior to the incorporation spray, samples prepared using α‐cyano‐4‐hydroxycinnamic acid (CHCA) and 2,5‐dihydroxybenzoic acid (DHB) as the matrix showed low signal while the sample using sinapinic acid (SA) initially exhibited good signal. Following the incorporation spray, the sample using SA did not show an increase in signal; the sample using DHB showed moderate gain factors of 2–5 (full ablation spectra) and 12–336 (raster spectra), while CHCA samples saw large increases in signal, with gain factors of 14–172 (full ablation spectra) and 148–1139 (raster spectra). Conclusions: The use of an incorporation spray to apply solvent by ESD to a matrix layer already deposited by ESD provides an increase in signal by both promoting incorporation of the analyte within and homogenizing the distribution of the incorporated analyte throughout the matrix layer. Copyright © 2017 John Wiley & Sons, Ltd.Keywords
This publication has 42 references indexed in Scilit:
- Detection of high molecular weight proteins by MALDI imaging mass spectrometryMolecular BioSystems, 2012
- Matrix Sublimation/Recrystallization for Imaging Proteins by Mass Spectrometry at High Spatial ResolutionAnalytical Chemistry, 2011
- From Whole-body Sections Down to Cellular Level, Multiscale Imaging of Phospholipids by MALDI Mass SpectrometryMolecular & Cellular Proteomics, 2011
- Mass Spectrometric Imaging for Biomedical Tissue AnalysisChemical Reviews, 2010
- Sample preparation issues for tissue imaging by imaging MSProteomics, 2009
- Unambiguous characterization and tissue localization of Pru P 3 peach allergen by electrospray mass spectrometry and MALDI imagingJournal of Mass Spectrometry, 2009
- Enhancement of protein sensitivity for MALDI imaging mass spectrometry after chemical treatment of tissue sectionsJournal of the American Society for Mass Spectrometry, 2008
- Development of a dual‐spray electrospray deposition system for matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 2008
- Exploring the Importance of the Relative Solubility of Matrix and Analyte in MALDI Sample Preparation Using HPLCAnalytical Chemistry, 2004
- Direct tissue analysis using matrix‐assisted laser desorption/ionization mass spectrometry: practical aspects of sample preparationJournal of Mass Spectrometry, 2003