Abstract
To confirm the quantitative accuracy of PIXE analysis instruments, we measured NIST SRM air particles on filter media using different types of PIXE analysis instrument: in-air micro-PIXE, in-air PIXE, in-vacuum PIXE, and in-vacuum micro-PIXE. Then, we compared the measured values with certified values and reference values of NIST SRM. We found that the quantitative values of the NIST SRM filter media measured with each PIXE instrument were within 90% to 110% of the NIST-certified and reference values for most elements. In particular, the quantitative values of major elements ranged from 90% to 110% for the in-air PIXE (Kyoto University), the in-vacuum PIXE, and the in-vacuum micro-PIXE at Tohoku University, and the relative errors are also small. These results will aid in determining the quantitative values of atmospheric particles on filter samples.Keywords
This publication has 18 references indexed in Scilit:
- Current status of the Tohoku microbeam system at Tohoku University and other facilitiesNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2023
- Automation of multi-modal beam focusing of an MeV sub-microprobe for ion beam analysisNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2021
- Elemental and immunohistochemical analysis of the lungs and hilar lymph node in a patient with asbestos exposure, a pilot studyEnvironmental Health and Preventive Medicine, 2016
- Improvement and recent applications of the Tohoku microbeam systemNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2014
- Developments in Dynamic Analysis for quantitative PIXE true elemental imagingNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2001
- Automated in situ trace element analysis of silicate materials by laser ablation inductively coupled plasma mass spectrometryAnalytical and Bioanalytical Chemistry, 2000
- Sub-micron microbeam apparatus for high resolution materials analysesNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1996
- Elemental Analysis of Environmental Samples by Total Reflection X-Ray Fluorescence: a ReviewX-Ray Spectrometry, 1996
- Personal computer aided data handling and analysis for PIXENuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1996
- Submicron microbeam apparatus using a single-ended accelerator with very high voltage stabilityNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995