Sho Toyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sho Toyama has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Shigeo Matsuyama
Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Japan
11 shared publications - Misako Miwa
Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Japan
9 shared publications Misako Miwa
Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, 6-6-01-2 Aoba Aramaki-Aza, Sendai, Miyagi, 980-8579, Japan
8 shared publicationsShigeo Matsuyama
Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, 6-6-01-2 Aoba Aramaki-Aza, Sendai, Miyagi, 980-8579, Japan; Center for Fundamental Research on Nuclear Decommissioning, Tohoku University, Sendai, Miyagi, 980-8579, Japan
6 shared publications- Kunihiro Ogawa
National Institutes of Natural Sciences
5 shared publications - Makoto Kobayashi
National Institute for Fusion Science, Toki, Japan
4 shared publications
Latest Publications
- Open Access
- 15 May 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 235, 112705
Alpha/beta discrimination in a position-sensitive fiber detector based on a pulse height method
- 15 May 2026
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 235, 112705
Open AccessAlpha/beta discrimination in a position-sensitive fiber detector based on a pulse height method
- Open Access
- 16 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 572
Calibration of an electrostatic accelerator for single-event-effects tests
- 16 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 572
Open AccessCalibration of an electrostatic accelerator for single-event-effects tests
- Open Access
- 26 May 2025
- Published by Elsevier in Journal of Luminescence
- Vol. 285
Evaluation of an outer-layer scintillating fiber designed for position-sensitive α-particle detectors
- 26 May 2025
- Published by Elsevier in Journal of Luminescence
- Vol. 285
Open AccessEvaluation of an outer-layer scintillating fiber designed for position-sensitive α-particle detectors
- 1 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 32 (01n04) , 15-22
Elemental analysis of NIST SRM air particulate on filter media using four different types of PIXE
To confirm the quantitative accuracy of PIXE analysis instruments, we measured NIST SRM air particles on filter media using different types of PIXE analysis instrument: in-air micro-PIXE, in-air PIXE, in-vacuum PIXE, and in-vacuum micro-PIXE. Then, we compared the measured values with certified values and reference values of NIST SRM. We found that the quantitative values of the NIST SRM filter media measured with each PIXE instrument were within 90% to 110% of the NIST-certified and reference values for most elements. In particular, the quantitative values of major elements ranged from 90% to 110% for the in-air PIXE (Kyoto University), the in-vacuum PIXE, and the in-vacuum micro-PIXE at Tohoku University, and the relative errors are also small. These results will aid in determining the quantitative values of atmospheric particles on filter samples.
- 1 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 32 (01n04) , 15-22
Elemental analysis of NIST SRM air particulate on filter media using four different types of PIXE
To confirm the quantitative accuracy of PIXE analysis instruments, we measured NIST SRM air particles on filter media using different types of PIXE analysis instrument: in-air micro-PIXE, in-air PIXE, in-vacuum PIXE, and in-vacuum micro-PIXE. Then, we compared the measured values with certified values and reference values of NIST SRM. We found that the quantitative values of the NIST SRM filter media measured with each PIXE instrument were within 90% to 110% of the NIST-certified and reference values for most elements. In particular, the quantitative values of major elements ranged from 90% to 110% for the in-air PIXE (Kyoto University), the in-vacuum PIXE, and the in-vacuum micro-PIXE at Tohoku University, and the relative errors are also small. These results will aid in determining the quantitative values of atmospheric particles on filter samples.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Application of a Single-Crystal CVD Diamond Detector for Fast Neutron Measurement in High Dose and Mixed Radiation Fields
This paper presents the method to evaluate the fast neutron energy spectrum using the single crystal CVD diamond detector to be applicable on the radiation monitoring in advanced scientific/engineering systems usually characterized with mixed and high-dose radiation field. The pulse shape discrimination based on the shape and the width of a pulse was applied to extract events in which fast neutron hits at the specific depth of the single crystal diamond. Unfolding of the measured spectrum for extracted pulses could deduce the neutron energy spectrum. Experiments using mono-energetic neutron sources demonstrated the reliable capability of this method to evaluate the neutron energy spectrum quantitatively.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Application of a Single-Crystal CVD Diamond Detector for Fast Neutron Measurement in High Dose and Mixed Radiation Fields
This paper presents the method to evaluate the fast neutron energy spectrum using the single crystal CVD diamond detector to be applicable on the radiation monitoring in advanced scientific/engineering systems usually characterized with mixed and high-dose radiation field. The pulse shape discrimination based on the shape and the width of a pulse was applied to extract events in which fast neutron hits at the specific depth of the single crystal diamond. Unfolding of the measured spectrum for extracted pulses could deduce the neutron energy spectrum. Experiments using mono-energetic neutron sources demonstrated the reliable capability of this method to evaluate the neutron energy spectrum quantitatively.
- Open Access
- 8 May 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (6) , 066026
Simultaneous measurements for fast neutron flux and tritium production rate using pulse shape discrimination and single crystal CVD diamond detector
This paper presents the development of a simultaneous measurement method for fast neutron energy spectra and tritium production rates within mixed radiation fields using a single crystal chemical vapour deposition diamond detector combined with a lithium fluoride (LiF) foil. The method involves the separation of pulses with rectangular shapes and the determination of the depth position within the single crystal diamond (SCD) struck by fast neutrons or nuclear reaction products including recoil tritons from the LiF foil based on pulse width, extracting pulse events occurred at the specific bulk region and the surface region of the SCD. Subsequently, unfolding techniques were employed to analyse the energy deposition spectrum of pulses at the specific bulk region which are induced only by fast neutrons, allowing the deduction of the fast neutron energy spectrum. To evaluate the tritium production rate, the energy deposition spectrum of pulses from events occurring at the SCD surface facing the LiF foil was analysed. By estimating the energy deposition spectrum solely induced by fast neutrons striking the SCD surface and subtracting it from the energy deposition spectrum of events at the SCD surface, the contribution of energetic ions, such as recoil tritons generated by the 6Li(n,α)3H reaction in the LiF foil, was determined. The fast neutron flux and tritium production rate obtained through this study were consistent with particle transport calculations, demonstrating the successful development of a method suitable for performance testing of fusion reactor blankets.
- 8 May 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (6) , 066026
Open AccessSimultaneous measurements for fast neutron flux and tritium production rate using pulse shape discrimination and single crystal CVD diamond detector
This paper presents the development of a simultaneous measurement method for fast neutron energy spectra and tritium production rates within mixed radiation fields using a single crystal chemical vapour deposition diamond detector combined with a lithium fluoride (LiF) foil. The method involves the separation of pulses with rectangular shapes and the determination of the depth position within the single crystal diamond (SCD) struck by fast neutrons or nuclear reaction products including recoil tritons from the LiF foil based on pulse width, extracting pulse events occurred at the specific bulk region and the surface region of the SCD. Subsequently, unfolding techniques were employed to analyse the energy deposition spectrum of pulses at the specific bulk region which are induced only by fast neutrons, allowing the deduction of the fast neutron energy spectrum. To evaluate the tritium production rate, the energy deposition spectrum of pulses from events occurring at the SCD surface facing the LiF foil was analysed. By estimating the energy deposition spectrum solely induced by fast neutrons striking the SCD surface and subtracting it from the energy deposition spectrum of events at the SCD surface, the contribution of energetic ions, such as recoil tritons generated by the 6Li(n,α)3H reaction in the LiF foil, was determined. The fast neutron flux and tritium production rate obtained through this study were consistent with particle transport calculations, demonstrating the successful development of a method suitable for performance testing of fusion reactor blankets.