Influence of deep learning image reconstruction and adaptive statistical iterative reconstruction-V on automated Alberta stroke program early CT score- evaluation
Open Access
- 18 February 2026
- journal article
- research article
- Published by Springer Nature in Neuroradiology
- Vol. 68 (4) , 953-963
Abstract
Purpose: The Alberta Stroke Program Early CT Score (ASPECTS) and advances in CT reconstruction play important roles in the neurodiagnostic workflow. This study examines the effect of these reconstruction techniques on automated ASPECTS. Methods: In this retrospective study, 173 patients (median age 79 years, 39% female) with suspected middle cerebral artery infarction underwent non-contrast CT scans reconstructed with Filtered Back Projection (FBP), ASIR-V (30% and 60%), and DLIR (low, medium, and high). Automated ASPECTS were analyzed, with FBP as the reference standard. Results: Bland–Altman analysis revealed a mean bias with ASIR and DLIR underestimating ASPECTS compared to FBP. This underestimation was less pronounced for ASIR-V 30% (-0.057 ) and DLIR-L (-0.069) than for ASIR-V 60% (-0.126), DLIR-M (-0.121), and DLIR-H (-0.086). The region with the greatest overestimation relative to FBP was M3 ( n = 23), while the region with the greatest underestimation was the insular ribbon ( n = 51). Regarding the ASPECTS < 6 threshold, most patients were reclassified from ASPECTS ≤ 5 to ASPECTS ≥ 6 with DLIR-M ( n = 5), which also showed the strongest agreement with expert consensus (κ = 0.352). Conclusion: Both ASIR-V and DLIR resulted in only minor underestimation of ASPECTS compared to FBP. However, most patients became eligible for endovascular therapy due to ASPECTS reclassification with DLIR-M. DLIR-M also exhibited the highest agreement with expert consensus for automated ASPECTS. Therefore, careful selection of reconstruction parameters, as well as further optimization and standardization of these techniques, is essential for broader application in stroke imaging.Keywords
All Related Versions
Funding Information
- Universitätsmedizin Rostock
This publication has 36 references indexed in Scilit:
- Deep learning-based computed tomography reconstruction improves image quality but does not significantly affect Alberta stroke program early CT score evaluation in acute middle cerebral artery territory infarctionNeuroradiology, 2025
- Improved CTA imaging for stroke evaluation – deep learning and iterative reconstruction comparative studyNeuroradiology, 2025
- Endovascular Stroke Thrombectomy for Patients With Large Ischemic CoreJAMA Neurology, 2024
- Association Between Alberta Stroke Program Early Computed Tomography Score and Efficacy and Safety Outcomes With Endovascular Therapy in Patients With Stroke From Large-Vessel OcclusionJAMA Neurology, 2022
- Image quality improvement in low‐dose chest CT with deep learning image reconstructionJournal of Applied Clinical Medical Physics, 2022
- Image quality and radiologists’ subjective acceptance using model-based iterative and deep learning reconstructions as adjuncts to ultrahigh-resolution CT in low-dose contrast-enhanced abdominopelvic CT: phantom and clinical pilot studiesAbdominal Radiology, 2021
- ASPECTS Interobserver Agreement of 100 Investigators from the TENSION StudyClinical Neuroradiology, 2021
- Deep learning–based image reconstruction for brain CT: improved image quality compared with adaptive statistical iterative reconstruction-Veo (ASIR-V)Neuroradiology, 2020
- Automated versus manual imaging assessment of early ischemic changes in acute stroke: comparison of two software packages and expert consensusEuropean Radiology, 2019
- Iterative reconstruction techniques for computed tomography Part 1: Technical principlesEuropean Radiology, 2013