Current biomedical research relies primarily on in silico studies to model complex systems like cardiovascular hemodynamics. However, for comprehensive validation of mathematical models, real in vitro experiments are indispensable. This paper introduces a framework that bridges these approaches through the hybrid mock circulatory loop (hMCL), offering precise control, flexibility, and reproducibility. This innovation enables the investigation of cardiovascular disease mechanisms in a controlled setting, overcoming the limitations of live organism studies. The framework employs a modified autoencoder with a partially guided latent space, incorporating physiological insights into a deep neural network. It leverages time-delayed cardiovascular signals, including pressures, flow rates, and unmeasurable cardiovascular system (CVS) parameters, to estimate critical parameters like aortic and mitral resistance, systemic resistance, and left ventricle elastance. The autoencoder’s loss function is tailored to predict these parameters, enhancing the understanding of cardiovascular dynamics. The study utilizes in silico data to train the model and validates it through in vitro tests using a hybrid mock loop device, yielding a remarkable accuracy of less than 5.7% error in replicating CVS signals. Furthermore, the framework demonstrates the adaptability of CVS variables to perturbations in closed-loop conditions and exhibits a diagnostic model with an impressive 98.55% F1 score for classifying cardiovascular disease severity. This research significantly advances the field by modifying the autoencoder to include physiological signals, introducing a novel loss function, developing a structured network, presenting a diagnostic model, and proposing an innovative approach for generating transient responses in cardiovascular hemodynamics, validated through in vitro and in silico experiments.Keywords
Funding Information
- Phinite Engineering and Technology Company (TGB-7001-069607)
This publication has 36 references indexed in Scilit:
- Left ventricular function: time-varying elastance and left ventricular aortic couplingCritical Care, 2016
- A lumped parameter mathematical model to analyze the effects of tachycardia and bradycardia on the cardiovascular systemInternational Journal of Numerical Modelling: Electronic Networks, Devices and Fields, 2014
- A mock circulation model for cardiovascular device evaluationPhysiological Measurement, 2014
- Replication of the Frank-Starling response in a mock circulation loop2011
- A Dynamical State Space Representation and Performance Analysis of a Feedback-Controlled Rotary Left Ventricular Assist DeviceIEEE Transactions on Control Systems Technology, 2008
- A Modified Elastance Model to Control Mock Ventricles in Real-Time: Numerical and Experimental ValidationASAIO Journal, 2008
- Design of a Sterile Organ Culture System for the Ex Vivo Study of Aortic Heart ValvesJournal of Biomechanical Engineering, 2005
- Sparse coding with an overcomplete basis set: A strategy employed by V1?Vision Research, 1997
- In Vitro and In Vivo Validation Tests for Total Artificial HeartArtificial Organs, 1994
- Comparison of the predicted and observed secondary structure of T4 phage lysozymeBiochimica et Biophysica Acta (BBA) - Protein Structure, 1975