Length of clinically proven cemented hip stems: State of the art or subject to improvement?
- 20 September 2014
- journal article
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (3) , 411-416
Abstract
The purpose of this study was to identify the shortest possible length of an established cemented hip stem in order to reduce stress shielding and optimise its bending behaviour. Twenty-five prototypes from the same batch (five for each stem length) were included. Lengths resulted from the original length (100 %) and four distal shortenings to 94, 88, 83 and 78 % of original length. For standardised implantations, synthetic femurs were prepared. Relative movements under axial torque and stem bending under varus–valgus torque applications were investigated consecutively. Analyses of variance (ANOVA) were applied to detect differences between lengths. The maximum torque transfer occurred at the level of the lesser trochanter (p < 0.01). In particular, for the 78 % version, relative motion of the stem tip increased significantly compared with all other lengths (p = 0.02-0.04). Comparable findings were made for mean overall movements. In regards to varus–valgus torque, both the distal tip and the proximal shoulder always bent in the same direction following the femoral deflection. For the 83 % version bending of stem’s shoulder was increased compared with the other length (p = 0.01 - 0.02), whereas tip bending was always comparable (p = 0.45-0.91). Our data show that the intention to preclinically optimise the mechanical behaviour of cemented stems by modifying their length seems to be a reasonable option. Advantages are decreased inner bone stiffening to reduce stress shielding and a lower cement volume, which is involved in cellular interactions.Keywords
This publication has 23 references indexed in Scilit:
- The effect of multifilaments and monofilaments on cementless femoral revision hip components: An experimental studyClinical Biomechanics, 2011
- Primary rotational stability of cylindrical and conical revision hip stems as a function of femoral bone defects: An in vitro comparisonJournal of Biomechanics, 2008
- Minimum 10-year Survival of Kerboull Cemented Stems According to Surface FinishClinical Orthopaedics and Related Research, 2008
- The design features of cemented femoral hip implantsThe Journal of Bone and Joint Surgery. British volume, 2006
- Der zementfreie CLS-Titangeradschaft - Langzeitergebnisse, Indikationen und LimitationenAktuelle Traumatologie, 2005
- Analysis of 16 Retrieved Proximally Cemented Femoral StemsThe Journal of Arthroplasty, 2005
- Excellent results from proximally HA-coated femoral stems with a minimum of 6 years follow-upActa Orthopaedica, 2005
- In Vivo surface wear mechanisms of femoral components of cemented total hip arthroplastiesThe Journal of Arthroplasty, 2004
- Bone cement with reduced proportion of monomer in total hip arthroplasty: Preclinical evaluation and randomized study of 47 cases with 5 years' follow-upActa Orthopaedica, 2001
- An infrared study of the interaction of polymethyl methacrylate with the protein and mineral components of bone.Journal of Histochemistry & Cytochemistry, 1992