A Fast and Accurate Transfer Function Validation Strategy Using Optimized Rotation-Invariant Lead Trajectories
- 3 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (3) , 673-680
Abstract
This article demonstrates a novel strategy to effectively and efficiently validate the lead transfer function model, which is used to predict the radiofrequency induced heating near the distal end of active implantable medical devices under magnetic resonance imaging exposure. The strategy uses the particle swarm optimization (PSO) algorithm to generate optimized rotation-invariant lead trajectories for arbitrary lead lengths in a rectangular phantom. The validation trajectories are generated by rotating a PSO optimized trajectory on a circular plate. The incident electric fields along these trajectories are minimally correlated resulting in very accurate validation. Compared with other validation trajectories used in the literature and recommended by ISO/TS 10974, the new method is significantly more robust, effective, accurate, and time efficient; and therefore, an ideal candidate for standardization.Keywords
This publication has 23 references indexed in Scilit:
- A Technique to Evaluate MRI-Induced Electric Fields at the Ends of Practical Implanted LeadIEEE Transactions on Microwave Theory and Techniques, 2014
- Assessment of local RF-induced heating of AIMDs during MR exposure2014
- Analysis of the Role of Lead Resistivity in Specific Absorption Rate for Deep Brain Stimulator Leads at 3T MRIIEEE Transactions on Medical Imaging, 2010
- Measurement, simulation and uncertainty assessment of implant heating during MRIPhysics in Medicine & Biology, 2009
- Measuring RF‐induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leadsMagnetic Resonance in Medicine, 2009
- Complexity of MRI induced heating on metallic leads: Experimental measurements of 374 configurationsBioMedical Engineering OnLine, 2008
- Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer functionJournal of Magnetic Resonance Imaging, 2007
- Numerical Evaluation of Heating of the Human Head Due to Magnetic Resonance ImagingIEEE Transactions on Biomedical Engineering, 2004
- Heating near implanted medical devices by the MRI RF-magnetic fieldIEEE Transactions on Magnetics, 1999
- Singular value decomposition and least squares solutionsNumerische Mathematik, 1970