Evaluation of Insertion Energy as Novel Parameter for Dental Implant Stability
Open Access
- 15 September 2020
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (9) , 2977
Abstract
Insertion energy has been advocated as a novel measure for primary implant stability, but the effect of implant length, diameter, or surgical protocol remains unclear. Twenty implants from one specific bone level implant system were placed in layered polyurethane foam measuring maximum insertion torque, torque–time curves, and primary stability using resonance frequency analysis (RFA). Insertion energy was calculated as area under torque–time curve applying the trapezoidal formula. Statistical analysis was based on analysis of variance, Tukey honest differences tests and Pearson’s product moment correlation tests (α = 0.05). Implant stability (p = 0.01) and insertion energy (p < 0.01) differed significantly among groups, while maximum insertion torque did not (p = 0.17). Short implants showed a significant decrease in implant stability (p = 0.01), while reducing implant diameter did not cause any significant effect. Applying the drilling protocol for dense bone resulted in significantly increased insertion energy (p = 0.02) but a significant decrease in implant stability (p = 0.04). Insertion energy was not found to be a more reliable parameter for evaluating primary implant stability when compared to maximum insertion torque and resonance frequency analysis.Keywords
This publication has 24 references indexed in Scilit:
- Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In Vitro Model StudyJournal of Oral Implantology, 2016
- Two Different Implant Designs and Impact of Related Drilling Protocols on Primary Stability in Different Bone Densities: An In Vitro Comparison StudyThe International Journal of Oral and Maxillofacial Implants, 2015
- Multiscale Analyses of the Bone-implant InterfaceJournal of Dental Research, 2015
- Primary Stability, Insertion Torque, and Bone Density of Conical Implants With Internal HexagonJournal of Craniofacial Surgery, 2013
- Biomechanical Evaluation of Undersized Drilling on Implant Biomechanical Stability at Early Implantation TimesJournal of Oral and Maxillofacial Surgery, 2013
- Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implantsJournal of the Mechanical Behavior of Biomedical Materials, 2012
- Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysisHead & Face Medicine, 2012
- Development of a New Implant Primary Stability Parameter: Insertion Torque RevisitedClinical Implant Dentistry and Related Research, 2011
- Initial stability and bone strain evaluation of the immediately loaded dental implant: an in vitro model studyClinical Oral Implants Research, 2010
- Influence of lateral pressure to the implant bed on osseointegration: an experimental study in dogsClinical Oral Implants Research, 2010