Anthony Dickinson
Research Subjects
Anthony Dickinson has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Constanze Steiner
Department of Prosthodontics Saarland University Homburg Germany
1 shared publication - Matthias Karl
Department of Prosthodontics, Philipps University Marburg, 35039 Marburg, Germany
1 shared publication - Siegfried Heckmann
Department of Prosthodontics, Saarland University, Kirrberger Strasse 100, 66421 Homburg, Germany
1 shared publication - Tanja Grobecker-Karl
Department of Prosthodontics, Saarland University, 66421 Homburg, Saar, Germany
1 shared publication
Latest Publications
- Open Access
- 15 September 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (9) , 2977
Evaluation of Insertion Energy as Novel Parameter for Dental Implant Stability
Insertion energy has been advocated as a novel measure for primary implant stability, but the effect of implant length, diameter, or surgical protocol remains unclear. Twenty implants from one specific bone level implant system were placed in layered polyurethane foam measuring maximum insertion torque, torque–time curves, and primary stability using resonance frequency analysis (RFA). Insertion energy was calculated as area under torque–time curve applying the trapezoidal formula. Statistical analysis was based on analysis of variance, Tukey honest differences tests and Pearson’s product moment correlation tests (α = 0.05). Implant stability (p = 0.01) and insertion energy (p < 0.01) differed significantly among groups, while maximum insertion torque did not (p = 0.17). Short implants showed a significant decrease in implant stability (p = 0.01), while reducing implant diameter did not cause any significant effect. Applying the drilling protocol for dense bone resulted in significantly increased insertion energy (p = 0.02) but a significant decrease in implant stability (p = 0.04). Insertion energy was not found to be a more reliable parameter for evaluating primary implant stability when compared to maximum insertion torque and resonance frequency analysis.
- 15 September 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (9) , 2977
Open AccessEvaluation of Insertion Energy as Novel Parameter for Dental Implant Stability
Insertion energy has been advocated as a novel measure for primary implant stability, but the effect of implant length, diameter, or surgical protocol remains unclear. Twenty implants from one specific bone level implant system were placed in layered polyurethane foam measuring maximum insertion torque, torque–time curves, and primary stability using resonance frequency analysis (RFA). Insertion energy was calculated as area under torque–time curve applying the trapezoidal formula. Statistical analysis was based on analysis of variance, Tukey honest differences tests and Pearson’s product moment correlation tests (α = 0.05). Implant stability (p = 0.01) and insertion energy (p < 0.01) differed significantly among groups, while maximum insertion torque did not (p = 0.17). Short implants showed a significant decrease in implant stability (p = 0.01), while reducing implant diameter did not cause any significant effect. Applying the drilling protocol for dense bone resulted in significantly increased insertion energy (p = 0.02) but a significant decrease in implant stability (p = 0.04). Insertion energy was not found to be a more reliable parameter for evaluating primary implant stability when compared to maximum insertion torque and resonance frequency analysis.