Siegfried Heckmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siegfried Heckmann has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Dickinson
Private Prosthodontic Practice, 1564 Malvern Road, Glen Iris 3146, Australia
1 shared publication - Constanze Steiner
Department of Prosthodontics Saarland University Homburg Germany
1 shared publication - Matthias Karl
Department of Prosthodontics, Philipps University Marburg, 35039 Marburg, Germany
1 shared publication Sonja Schneider
1 shared publication- Tanja Grobecker-Karl
Department of Prosthodontics, Saarland University, 66421 Homburg, Saar, Germany
1 shared publication
Latest Publications
- Open Access
- 15 September 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (9) , 2977
Evaluation of Insertion Energy as Novel Parameter for Dental Implant Stability
Insertion energy has been advocated as a novel measure for primary implant stability, but the effect of implant length, diameter, or surgical protocol remains unclear. Twenty implants from one specific bone level implant system were placed in layered polyurethane foam measuring maximum insertion torque, torque–time curves, and primary stability using resonance frequency analysis (RFA). Insertion energy was calculated as area under torque–time curve applying the trapezoidal formula. Statistical analysis was based on analysis of variance, Tukey honest differences tests and Pearson’s product moment correlation tests (α = 0.05). Implant stability (p = 0.01) and insertion energy (p < 0.01) differed significantly among groups, while maximum insertion torque did not (p = 0.17). Short implants showed a significant decrease in implant stability (p = 0.01), while reducing implant diameter did not cause any significant effect. Applying the drilling protocol for dense bone resulted in significantly increased insertion energy (p = 0.02) but a significant decrease in implant stability (p = 0.04). Insertion energy was not found to be a more reliable parameter for evaluating primary implant stability when compared to maximum insertion torque and resonance frequency analysis.
- 15 September 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (9) , 2977
Open AccessEvaluation of Insertion Energy as Novel Parameter for Dental Implant Stability
Insertion energy has been advocated as a novel measure for primary implant stability, but the effect of implant length, diameter, or surgical protocol remains unclear. Twenty implants from one specific bone level implant system were placed in layered polyurethane foam measuring maximum insertion torque, torque–time curves, and primary stability using resonance frequency analysis (RFA). Insertion energy was calculated as area under torque–time curve applying the trapezoidal formula. Statistical analysis was based on analysis of variance, Tukey honest differences tests and Pearson’s product moment correlation tests (α = 0.05). Implant stability (p = 0.01) and insertion energy (p < 0.01) differed significantly among groups, while maximum insertion torque did not (p = 0.17). Short implants showed a significant decrease in implant stability (p = 0.01), while reducing implant diameter did not cause any significant effect. Applying the drilling protocol for dense bone resulted in significantly increased insertion energy (p = 0.02) but a significant decrease in implant stability (p = 0.04). Insertion energy was not found to be a more reliable parameter for evaluating primary implant stability when compared to maximum insertion torque and resonance frequency analysis.
- 7 August 2019
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 128 (07/08) , 361-369
Zirkonteleskope bei abnehmbarem Zahnersatz – eine Zwischenbilanz
Zirkonprimärteleskope und Galvanosekundärkronen finden zunehmend Verwendung bei der Stabilisierung abnehmbarer Prothesenkonstruktionen. In der vorliegenden Studie wird der Herstellungsprozess einer derartigen Versorgung dargestellt. Darüber hinaus ermittelte man anhand einer Nachuntersuchung von langjährig getragenen Zirkonteleskopen ihren biologischen Zustand. Hierzu wurden Plaque und Verfärbungen an den Teleskopkronen bestimmt, der modifizierte Sulcus-Blutungs-Index (mSBI) und Blutung-auf-Sondieren-Index (BOP) erhoben, Taschentiefen gemessen und der Lockerungsgrad ermittelt. Die Ergebnisse zeigen, dass Primärteleskope aus Zirkoniumdioxid, die eine abnehmbare Prothese stabilisieren, eine erfolgversprechende Therapiemöglichkeit darstellen und auch nach Jahren einen zufriedenstellenden parodontalen Zustand aufweisen.
- 7 August 2019
- Published by Georg Thieme Verlag KG in ZWR - Das Deutsche Zahnärzteblatt
- Vol. 128 (07/08) , 361-369
Zirkonteleskope bei abnehmbarem Zahnersatz – eine Zwischenbilanz
Zirkonprimärteleskope und Galvanosekundärkronen finden zunehmend Verwendung bei der Stabilisierung abnehmbarer Prothesenkonstruktionen. In der vorliegenden Studie wird der Herstellungsprozess einer derartigen Versorgung dargestellt. Darüber hinaus ermittelte man anhand einer Nachuntersuchung von langjährig getragenen Zirkonteleskopen ihren biologischen Zustand. Hierzu wurden Plaque und Verfärbungen an den Teleskopkronen bestimmt, der modifizierte Sulcus-Blutungs-Index (mSBI) und Blutung-auf-Sondieren-Index (BOP) erhoben, Taschentiefen gemessen und der Lockerungsgrad ermittelt. Die Ergebnisse zeigen, dass Primärteleskope aus Zirkoniumdioxid, die eine abnehmbare Prothese stabilisieren, eine erfolgversprechende Therapiemöglichkeit darstellen und auch nach Jahren einen zufriedenstellenden parodontalen Zustand aufweisen.