Seismic Retrofit Using Rocking Walls and Steel Dampers
- 7 December 2009
- conference paper
- Published by American Society of Civil Engineers (ASCE)
- p. 1010-1021
Abstract
A retrofit system of prestressed concrete rocking walls and steel dampers is used to control the seismic damage mode and increase the strength and energy dissipating capacity of an 11 story steel reinforced concrete frame in Japan. Important details of the retrofit design are introduced. The seismic performance of the structure before and after the retrofit is evaluated through extensive nonlinear time history analysis. Results show that the rocking system can significantly reduce both the seismic responses to different earthquake ground motions and their scattering. This makes the damage mode and the seismic performance of the retrofitted building more predictable, leading to a possibility of more reliable performance-based seismic design.Keywords
This publication has 3 references indexed in Scilit:
- Dynamic testing of precast, post-tensioned rocking wall systems with alternative dissipating solutionsBulletin of the New Zealand Society for Earthquake Engineering, 2008
- Shaking table tests on seismic response of steel braced frames with column upliftEarthquake Engineering & Structural Dynamics, 2006
- Rocking Wall–Frame Structures with Supplemental Tendon SystemsJournal of Structural Engineering, 2004