S. Motoyui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S. Motoyui has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Akira Wada
Tokyo Institute of Technology
1 shared publication H. Ito
Professor, Structural Engineering Research Center, Tokyo Institute of Technology, Nagatsuta, Midori, Yokohama, 226-8503, Japan
1 shared publication- H. Sakata
Professor, Structural Engineering Research Center, Tokyo Institute of Technology, Nagatsuta, Midori, Yokohama, 226-8503, Japan
1 shared publication - Kazuhiko Kasai
Tokyo Institute of Technology, Japan
1 shared publication - Z. Qu
Postdoctoral Fellow, Dept. of Civil Engineering, Univ. of Sherbrooke, Sherbrooke PQ, Canada J1K 2R1
1 shared publication
Latest Publications
- 7 December 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1010-1021
Seismic Retrofit Using Rocking Walls and Steel Dampers
A retrofit system of prestressed concrete rocking walls and steel dampers is used to control the seismic damage mode and increase the strength and energy dissipating capacity of an 11 story steel reinforced concrete frame in Japan. Important details of the retrofit design are introduced. The seismic performance of the structure before and after the retrofit is evaluated through extensive nonlinear time history analysis. Results show that the rocking system can significantly reduce both the seismic responses to different earthquake ground motions and their scattering. This makes the damage mode and the seismic performance of the retrofitted building more predictable, leading to a possibility of more reliable performance-based seismic design.
- 7 December 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1010-1021
Seismic Retrofit Using Rocking Walls and Steel Dampers
A retrofit system of prestressed concrete rocking walls and steel dampers is used to control the seismic damage mode and increase the strength and energy dissipating capacity of an 11 story steel reinforced concrete frame in Japan. Important details of the retrofit design are introduced. The seismic performance of the structure before and after the retrofit is evaluated through extensive nonlinear time history analysis. Results show that the rocking system can significantly reduce both the seismic responses to different earthquake ground motions and their scattering. This makes the damage mode and the seismic performance of the retrofitted building more predictable, leading to a possibility of more reliable performance-based seismic design.