Interobserver agreement between central topography and Scheimpflug tomography for premium intraocular lens selection
- 1 August 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (8) , 790-794
Abstract
Purpose: To assess the inter-observer agreement and reliability of central topography (CT) of IOL Master 700 with that of Pentacam HR, as a screening tool for determining the suitability for premium (toric, monofocal and presbyopia correcting) intraocular lens (IOL) implants. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Method: 200 eyes of eligible patients undergoing unilateral or bilateral phacoemulsification with premium IOL's were included in the study. Preoperatively, IOL Master 700 CT and Pentacam scans were performed for corneal topography evaluation. 2 experienced clinicians were randomised to interpret the axial map of either of the scans at a time and their responses were then enclosed in an envelope, and forwarded to a third observer for analysis. If there was a conflict, final decision was based on the interpretation of the Pentacam scan. Results: Of the total scans interpreted by the 2 observers, 77.5% (n = 155) showed agreement whereas 22.5% (n = 45) showed disagreement. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of IOL Master 700 CT in diagnosing irregular corneas when compared with Pentacam HR, was 72.73%, 78.09%, 29.09% and 95.86% respectively. The Cohen's κ inter-observer agreement value was 0.44, signifying a moderate degree of agreement, which was statistically significant (P < .00). Conclusions: High NPV of IOL Master CT suggested that the device efficiently ruled out irregular corneas, while any suspicious scan should be confirmed with Pentacam HR or a similar device for appropriate decision-making regarding premium IOL selection. Trial Registration Number: CTRI/2021/11/038053.Keywords
This publication has 18 references indexed in Scilit:
- Corneal Topography for Intraocular Lens Selection in Refractive Cataract SurgeryOphthalmology, 2021
- Comparison of central topographic maps from a swept-source OCT biometer and a Placido disk–dual Scheimpflug tomographerJournal of Cataract & Refractive Surgery, 2020
- Comparison of Preoperative Parameter Measurements Using an Optical Biometer, Automated Keratometer, and a Placido-Based Topographer ModuleEye & Contact Lens: Science & Clinical Practice, 2020
- Comparison of a new Scheimpflug imaging combined with partial coherence interferometry biometer and a low-coherence reflectometry biometerJournal of Cataract & Refractive Surgery, 2017
- Clinical outcomes after implantation of a toric intraocular lens with a transitional conic toric surfaceBritish Journal of Ophthalmology, 2017
- Comparison of biometry and intraocular lens power calculation performed by a new optical biometry device and a reference biometerJournal of Cataract & Refractive Surgery, 2017
- Progress in Modern Cataract Surgery – New Steps and Algorithms for Precise Measuring and Intraocular-lens CalculationsEuropean Ophthalmic Review, 2017
- Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMasterBritish Journal of Ophthalmology, 2016
- Dissatisfaction after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2009
- Maximizing Satisfaction with Presbyopia-Correcting Intraocular Lenses: The Missing LinksAmerican Journal of Ophthalmology, 2008