Abstract
Bulk current injection (BCI) is a commonly used method in electromagnetic compatibility testing. In order to enhance the injection efficiency of the current probe, the interference process into the internal core wire is analyzed. Theoretical calculations indicate that the shielded multi-core wire exhibits a frequency-selective response under BCI conditions. The peak of the terminal load response voltage occurs at frequencies corresponding to the integral multiples of half the relative length of the cable. The position of the current probe along the cable only affects the amplitude of the distributed current on the shielding layer, but not its distribution pattern. The response of the internal core wire at the resonant frequencies is positively correlated with the distribution pattern of the distributed current on the shielding layer. The probe position has a significant effect on the magnitude of the wire-to-terminal response. Placing the current probe at both ends of the cable results in high injection efficiency and significant power savings.Keywords
Funding Information
- National Defense Basic Scientific Research Program of China (JCKYS2022DC02)
This publication has 8 references indexed in Scilit:
- Equivalent Measurement Method for High-Field-Intensity Radiation Sensitivity of Two-Wire Interconnection SystemIEEE Transactions on Instrumentation and Measurement, 2024
- Comparison of Shielding Effectiveness of Different Shielding Methods for Multi-Core Cable on Lightning Surge CurrentIEEE Transactions on Electromagnetic Compatibility, 2022
- Characterization of the Susceptibility to EMI of a BMS IC for Electric Vehicles by Direct Power and Bulk Current InjectionIEEE Letters on Electromagnetic Compatibility Practice and Applications, 2021
- An Equivalent Dynamic Test System for Immunity Characterization of the UAV Positioning Module Using Bulk Current Injection MethodIEEE Letters on Electromagnetic Compatibility Practice and Applications, 2020
- Bulk Current Injection as an Alternative Radiated Susceptibility Test Enforcing a Statistically Quantified Overtesting MarginIEEE Transactions on Electromagnetic Compatibility, 2018
- Bulk Current Injection in Twisted Wire Pairs With Not Perfectly Balanced TerminationsIEEE Transactions on Electromagnetic Compatibility, 2013
- The Concept of Weak Imbalance and Its Role in the Emissions and Immunity of Differential LinesIEEE Transactions on Electromagnetic Compatibility, 2013
- Use of Double Bulk Current Injection for Susceptibility Testing of AvionicsIEEE Transactions on Electromagnetic Compatibility, 2008