Proximal Interphalangeal Arthrodesis of Lesser Toes Utilizing K-Wires Versus Expanding Implants: Comparative Biomechanical Cadaveric Study
- 20 October 2018
- journal article
- research article
- Published by SAGE Publications in Foot & Ankle International
- Vol. 40 (2) , 231-236
Abstract
Lesser toe proximal interphalangeal (PIP) joint arthrodesis is one of the most common foot and ankle elective procedures often using K-wires for fixation. K-wire associated complications led to development of intramedullary fixation devices. We hypothesized that X Fuse (Stryker) and Smart Toe (Stryker) would provide stronger and stiffer fixation than K-wire fixation. 12 cadaveric second toe pairs were used. In one group, K-wires stabilized 6 PIP joints, and 6 contralateral PIP joints were fixed with X Fuse. A second group used K-wires to stabilize 6 PIP joints, and 6 contralateral PIP joints were fixed with Smart Toe. Specimens were loaded cyclically with extension bending using 2-N step increases (10 cycles per step). Load to failure and initial stiffness were assessed. Statistical analysis used paired t tests. K-wire average failure force, 91.0 N (SD 28.3), was significantly greater than X Fuse, 63.3 N (SD 12.9) (P < .01). K-wire average failure force, 102.3 N (SD 17.7), was also significantly greater than Smart Toe, 53.3 N (SD 18.7) (P < .01). K-wire initial stiffness 21.3 N/mm (SD 5.7) was greater than Smart Toe 14.4 N/mm (SD 9.3) (P = .02). K-wire failure resulted from bending of K-wire or breaching cortical bone. X Fuse typically failed by implant pullout. Smart Toe failure resulted from breaching cortical bone. K-wires may provide stiffer and stronger constructs in extension bending than the X Fuse or Smart Toe system. This cadaver study assessed stability of the fusion site at time zero after surgery. Our findings provide new data supporting biomechanical stability of K-wires for lesser toe PIP arthrodesis, at least in this clinically relevant mode of cyclic loading.Keywords
This publication has 16 references indexed in Scilit:
- Use of Smart Toe© implant for small toe arthrodesis: A smart concept?Foot and Ankle Surgery, 2015
- Prospective Study of Hammertoe Correction With an Intramedullary ImplantFoot & Ankle International, 2014
- Stabilization of Proximal Interphalangeal Joint in Lesser Toe Deformities With an Angulated Intramedullary ImplantFoot & Ankle International, 2014
- Smart Toe® Implant Versus Buried Kirschner Wire for Proximal Interphalangeal Joint Arthrodesis: A Comparative StudyThe Journal of Foot and Ankle Surgery, 2013
- Using a Bone Allograft to Fixate Proximal Interphalangeal Joint ArthrodesisFoot & Ankle Specialist, 2013
- SmartToe® Implant Compared with Kirschner Wire Fixation for Hammer Digit Corrective Surgery: A Review of 28 PatientsThe Journal of Foot and Ankle Surgery, 2012
- Early Complications and Recurrence Rates After Kirschner Wire Transfixion in Lesser Toe Surgery: A Prospective Randomized StudyFoot & Ankle International, 2012
- Hammer Toe Correction Using an Absorbable Intramedullary PinFoot & Ankle International, 2007
- A Bioabsorbable Fixation Implant for Use in Proximal Interphalangeal Joint (Hammer Toe) Arthrodesis: Biomechanical Testing in a Synthetic Bone SubstrateThe Journal of Foot and Ankle Surgery, 2006
- Kirschner Wire Breakage after Surgery of the Lesser ToesFoot & Ankle International, 1995