UAUmur Aydogan

Umur Aydogan

*This is an algorithmically generated author record based on publicly available information.

Umur Aydogan has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Halluks valgus revizyon cerrahisi

    by Tahir Öğüt, Umur Aydoğan

  • Open Access

    Achilles tendon moment arm changes with total ankle arthroplasty

    by Francesca E. Wade, Lauren J. Hickox, Gregory S. Lewis, Andrea Horne, Michael C. Aynardi, Paul J. Juliano, Umur Aydogan, Stephen J. Piazza

    Prior research on total ankle arthroplasty (TAA) has focused on improvements in pain and function following the surgical treatment of ankle arthritis, but its effect on ankle joint mechanics has received relatively little attention. The plantarflexion moment arm of the Achilles tendon is a critical determinant of ankle function with the potential to be altered by TAA. Here we investigate the effect of TAA on Achilles tendon moment arm assessed using two methods. Standing sagittal‐plane radiographs were obtained for ten patients presurgery and postsurgery, from which anterior–posterior distance between the posterior calcaneus and the center of the talar dome was measured. Ultrasound imaging and three‐dimensional (3D) motion capture were used to obtain moment arm pre‐ and post‐TAA. The absolute changes in moment arm pre‐ to post‐TAA were significantly different from zero for both methods (9.6 mm from ultrasound and 4.6% of the calcaneus length from radiographs). Only 46% of the variance in postoperative 3D Achilles tendon moment arm was explained by the preoperative value (r2 = 0.460; p = .031), while pre‐ and post‐TAA values from radiographs were not correlated (r2 = 0.192, p = .206). While we did not find significant mean differences in Achilles tendon moment arm between pre‐ and post‐TAA, we did find absolute changes in 3D moment arm that were significantly different from zero and these changes were partially explained by a change in location of the talar dome as indicated by measurements from radiographs (r2 = 0.497, p = .023).


  • Effects of variations in Dwyer calcaneal osteotomy determined by three‐dimensional printed patient‐specific modeling

    by Kent Weinheimer, Brett Campbell, Evan P. Roush, Gregory S. Lewis, Allen Kunselman, Umur Aydogan

    Dwyer (lateral calcaneal closing wedge) osteotomy is commonly used in surgical correction of heel varus deformity. The purpose of this study was to determine the effect of wedge size and angle of osteotomy on deformity correction using preoperative imaging analysis with three‐dimensional (3D) printed modeling. Seven patients diagnosed with pes cavovarus deformity who underwent Dwyer calcaneal osteotomy were identified retrospectively. Preoperative computed tomogrphy scans were used to create 3D printed models of the foot. After18 variations of osteotomy and fixation performed for each foot, Harris heel and Saltzman images were obtained. The angle between the tibia‐talus axis and calcaneal‐tuber axis was measured and compared to pre‐osteotomy state. Change in the calcaneal lengths was also analyzed. The average degree correction of deformity per mm of bone resected was 3.8 ± 0.2 degrees in the Harris Heel view and 2.7 ± 0.8 degrees in the Saltzman view. A significant increase in correction was obtained with 10 mm compared with 5 mm wide wedges (P < .001). The difference in correction was not statistically significant between 30 and 45 degree cuts or osteotomy distance from the posterior calcaneal tuberosity, but a 45 degree sagittal angle resulted in less calcaneal shortening compared to 30 degrees (P = .02). A clinically driven method using patient‐specific 3D models for determining effects of calcaneal osteotomy variables in correcting hindfoot alignment was developed. In summary, the amount of wedge resected impacts hindfoot alignment more than location and sagittal angle of the cut. Calcaneal shortening depends on sagittal angle of the cut.


  • Demographic Distribution of Foot and Ankle Surgeries Among Orthopaedic Surgeons and Podiatrists: A 10-Year Database Retrospective Study

    by Alex Burton, Michael C. Aynardi, Umur Aydogan

    Background: Foot and ankle surgeries in the United States (US) are currently performed by orthopaedic surgeons or podiatrists with specialty surgical training. With the trend in healthcare now placing increased emphasis on quality and standardizing patient care, this study aimed to characterize the distribution, volume, and trends of certain foot and ankle surgeries performed in the US by both orthopaedic surgeons and podiatrists. Materials and Methods: A retrospective analysis was performed using the Marketscan Claims Database (Truven Health Analytics, Ann Arbor, Michigan) which covers most privately insured patients under the age of 65 in the USA from 2005 to 2014. We searched current procedural terminology (CPT) codes for total ankle replacement (TAR), triple arthrodesis, hallux valgus correction, pilon fracture open reduction and internal fixation (ORIF), calcaneus fracture ORIF, and ankle fracture ORIF. We recorded the timing and nature of procedures along with various features associated with the surgeon and the geographic location of the treatment facility. Results: We found that the number of foot and ankle procedures performed annually is steadily increasing. Orthopaedic surgeons are the main treating surgeon for common foot and ankle traumatic conditions or complex hind foot cases like TAR. On the other hand, our study showed that podiatrists perform almost 9 out of 10 hallux valgus correction surgeries. Discussion: Our study showed the trends in surgical volumes and differences between surgical podiatrists and orthopaedic surgeons and the evolution of these volumes over a ten year period and differences in surgical repertoire between orthopaedists and podiatrists. Levels of Evidence: Level IV: Case series, Clinical research


  • Structural remodeling of fibrillar collagens in posterior tibial tendinopathy in three dimensional space identified using multiphoton and second harmonic generation imaging

    by Thomas Abraham, Rebecca Koob, Nurgul Carkaci-Salli, Umur Aydogan

    Posterior tibial tendon dysfunction is one of the most common causes of acquired flat foot deformity in adults, and results in significant morbidity due to the pain and development of secondary osteoarthritis. The exact etiology of this condition is still unknown. Tibial tendons are predominately made up of fibrillar collagens and we hypothesis that their structural properties such as the collagen fiber density, orientation properties and cross-linking density essentially control the biomechanical properties of posterior tibial tendons. In this study, our aim is to visualize and quantitate fibrillar collagen distributions, their organization, crosslink densities and the fiber orientation (using Fourier analysis) in three distinct regions of posterior tibial tendon human samples namely proximal, middle and distal regions. The experiments conducted here are based on tendon specimens donated for research by persons that have their diseased tendon removed prior to surgery. Multiphoton microscopy provides a powerful imaging method for evaluation of remodeling of fibrillar collagen structures deep within tissues. Ultra-short IR laser pulses served as an excitation source to produce multiphoton excitation fluorescence (MPEF) from endogenously fluorescent macromolecular systems and to induce highly specific second harmonic generation (SHG) signals from fibrillar collagens. We systematically examined the nature of fibrillar collagen remodelling in relatively thick posterior tibial tendon tissues. Computed Orientation Index values obtained from Fourier analysis show statistically significant differences particularly between proximal and middle regions (p<0.0001). The crosslinking densities determined from the ratio of auto-fluorescence (MPEF) to BSHG again show differences particularly between proximal and middle regions (p<0.01). We have successfully demonstrated that the multiphoton and harmonic generation microscopy can be a powerful high resolution imaging method requiring minimal sample preparation that can provide structural information about spatially and spectrally resolved fibrillar collagens in three different posterior tibial tendon tendon regions.

  • Open Access

    Detection of the Tendon Properties in Posterior Tibial Tendinopathy in Three-Dimensional Space Using High Resolution Multiphoton and Second Harmonic Generation Imaging

    by Thomas Abraham, Kristen (Rebecca) Koob, Nurgul Carkaci-Salli, Umur Aydogan

    Category: Hindfoot Introduction/Purpose: Posterior tibial tendon dysfunction is the most common cause of acquired flat foot deformity in adults, and results in significant morbidity. The exact etiology of this condition is still unknown. Posterior tibial tendon is predominately made up of fibrillar collagens and we hypothesize that their structural properties such as the collagen fiber density, orientation properties and cross-linking density essentially control the biomechanical properties of posterior tibial tendons. In this study, our aim is to visualize and quantitate fibrillar collagen distributions, their organization, cross-link densities and the fiber orientation (using Fourier analysis) in three distinct regions of pathologic posterior tibial tendon human samples namely proximal, middle and distal regions. Methods: After an institutional IRB approval we obtained diseased posterior tibial tendon total excision samples from 10 patients that had reconstructive procedures for posterior tibial tendinopathy at our institution and two fresh non-frozen healthy posterior tibial tendon samples from cadavers were used as the control. This research mainly utilized well established multiphoton microscopy and harmonic generation methodologies which compared proximal, middle and distal 1/3 of the tendon samples; multiphoton microscopy provides a powerful imaging method for evaluation of remodeling of fibrillar collagen structures deep within tissues. Ultra-short IR laser pulses served as an excitation source to produce multiphoton excitation fluorescence (MPEF) from endogenously fluorescent macromolecular systems and to induce highly specific second harmonic generation (SHG) signals from fibrillar collagens. Since MPEF and SHG involve different principles and contrast mechanisms, they were captured simultaneously to provide spectrally and spatially resolved, quantitative imaging of complex structures. Results: We systematically examined the nature of fibrillar collagen remodeling in relatively thick posterior tibial tendon tissues. Representative 3D forward SHG (FSHG), backward SHG (BSHG) and auto-fluorescence (MPEF) images originating from fibrillar collagen matrix from relatively thick (~50 microns) posterior tibial tendon sections of three different regions namely proximal, middle and distal regions are shown in Figure 1. Computed Orientation Index values obtained from Fourier analysis show statistically significant differences particularly between proximal and middle regions (decreased orientation of collagen fibers in the middle region, p<0.0001). The cross-linking densities determined from the ratio of auto-fluorescence (MPEF) to BSHG again show differences particularly between proximal and middle regions (increased cross-linking in the middle region, p<0.01). Conclusion: The multiphoton and harmonic generation microscopy can be a powerful high resolution imaging method requiring minimal sample preparation that can provide structural information about spatially and spectrally resolved fibrillar collagens in three different posterior tibial tendon tendon regions. We found that middle third of the pathologic tendons show increased cross-linking and decreased orientation ratio of the collagen fibers which can provide insight into the regional based collagen remodeling and improved understanding of earliest stages of tendon destruction that could lead to improvements in the treatment of this condition.


  • Distal fibula osteotomies improve tibiotalar joint compression: A biomechanical study in a cadaveric model

    by Christopher B. Arena, Evan P. Roush, Allen R. Kunselman, Paul J. Juliano, Umur Aydogan, Gregory S. Lewis


  • Proximal Interphalangeal Arthrodesis of Lesser Toes Utilizing K-Wires Versus Expanding Implants: Comparative Biomechanical Cadaveric Study

    by Shane D. Rothermel, Umur Aydogan, Evan P. Roush, Gregory S. Lewis

    Lesser toe proximal interphalangeal (PIP) joint arthrodesis is one of the most common foot and ankle elective procedures often using K-wires for fixation. K-wire associated complications led to development of intramedullary fixation devices. We hypothesized that X Fuse (Stryker) and Smart Toe (Stryker) would provide stronger and stiffer fixation than K-wire fixation. 12 cadaveric second toe pairs were used. In one group, K-wires stabilized 6 PIP joints, and 6 contralateral PIP joints were fixed with X Fuse. A second group used K-wires to stabilize 6 PIP joints, and 6 contralateral PIP joints were fixed with Smart Toe. Specimens were loaded cyclically with extension bending using 2-N step increases (10 cycles per step). Load to failure and initial stiffness were assessed. Statistical analysis used paired t tests. K-wire average failure force, 91.0 N (SD 28.3), was significantly greater than X Fuse, 63.3 N (SD 12.9) (P < .01). K-wire average failure force, 102.3 N (SD 17.7), was also significantly greater than Smart Toe, 53.3 N (SD 18.7) (P < .01). K-wire initial stiffness 21.3 N/mm (SD 5.7) was greater than Smart Toe 14.4 N/mm (SD 9.3) (P = .02). K-wire failure resulted from bending of K-wire or breaching cortical bone. X Fuse typically failed by implant pullout. Smart Toe failure resulted from breaching cortical bone. K-wires may provide stiffer and stronger constructs in extension bending than the X Fuse or Smart Toe system. This cadaver study assessed stability of the fusion site at time zero after surgery. Our findings provide new data supporting biomechanical stability of K-wires for lesser toe PIP arthrodesis, at least in this clinically relevant mode of cyclic loading.


  • Avoiding Pitfalls of Tibiotalocalcaneal Nail Malposition With Internal Rotation Axial Heel View

    by Ryan Callahan, Paul Juliano, Umur Aydogan, Justin Clayton

    Background. Tibiotalocalcaneal (TTC) nails are often used for complex hind foot arthrodesis and deformity correction. The natural valgus alignment of the hindfoot creates a challenge to optimum placement of the guidewire and eventual nail with a straight or valgus-curved nail. Methods. Five fresh frozen cadavers were used for placement of a TTC guidewire with standard anterior-posterior (AP), lateral, and Harris axial heel views as a reference for proper placement. The limb was then rotated 15°, 30°, and 45° both internally and externally to evaluate the perceived amount of osseous purchase within the calcaneus. The TTC nail was then inserted and dissection was performed to demonstrate proximity of the nail to the sustentaculum tali and neurovascular structures. Results. A 30° internal rotation Harris axial heel view demonstrated the most accurate representation of osseous purchase within the calcaneus with the guidewire and nail placement. When the guidewire was placed with standard imaging the nail was often ultimately placed in close proximity to the sustentaculum tali and neurovascular structures. Conclusion. Careful placement of the guidewire prior to reaming and nail placement should be undertaken to avoid neurovascular injury and to increase osseous purchase. For optimal guidewire placement, the authors suggest using appropriate anatomic landmarks and using a 30° internally rotated Harris axial heel view to verify correct placement. Levels of Evidence: Level V: Expert opinion