Background: Few dosimetric comparisons have been published between linear accelerator (LA)-based systems and CyberKnife (CK)-based robotic radiosurgery systems for cardiac radio-ablation in ventricular tachycardia. This study aimed to compare the dosimetry of noninvasive cardiac radio-ablation deliverable on LA with that on CK. Methods: Thirteen patients who underwent noninvasive cardiac radio-ablation by LA were included. The prescribed dose was 25 Gy in 1 fraction, and the average planning target volume was 49.8 ± 31.0 cm3 (range, 14.4–93.7 cm3). CK plans were generated for comparison. Results: Both the CK and LA plans accomplished appropriate dose coverage and normal tissue sparing. Compared with the LA plans, the CK plans achieved significantly lower gradient indices (3.12 ± 0.71 vs. 3.48 ± 0.55, p = 0.031) and gradient measures (1.00 ± 0.29 cm vs. 1.17 ± 0.29 cm, p < 0.001). They had similar equivalent conformity indices (CK vs. LA: 0.84 ± 0.08 vs. 0.87 ± 0.07, p = 0.093) and maximum doses 2 cm from the planning target volume (PTV) in any direction (CK vs. LA: 50.8 ± 9.9% vs. 53.1 ± 5.3%, p = 0.423). The dosimetric advantages of CK were more prominent in patients with a PTV of ≤ 50 cm3 or a spherical PTV. In patients with a PTV of > 50 cm3 or a non-spherical PTV, the LA and CK plans were similar regarding dosimetric parameters. CK plans involved more beams (232.2 ± 110.8 beams vs. 10.0 ± 1.7 arcs) and longer treatment times (119.2 ± 43.3 min vs. 22.4 ± 1.6 min, p = 0.007). Conclusions: Both CK and LA are ideal modalities for noninvasive cardiac radio-ablation. Upfront treatment should be considered based on clinical intent.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (110-2314-B-002-138-MY3)
- National Taiwan University Hospital (111-S0025)
This publication has 32 references indexed in Scilit:
- Dosimetric comparison between cone/Iris‐based and InCise MLC‐based CyberKnife plans for single and multiple brain metastasesJournal of Applied Clinical Medical Physics, 2016
- Standardization of terminology in stereotactic radiosurgery: Report from the Standardization Committee of the International Leksell Gamma Knife SocietyJournal of Neurosurgery, 2014
- Stereotactic body radiation therapy (SBRT) for prostate cancer in men with large prostates (≥50 cm3)Radiation Oncology, 2014
- Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancerJournal of Radiation Research, 2014
- Robotic radiosurgery versus micro-multileaf collimator: a dosimetric comparison for large or critically located arteriovenous malformationsRadiation Oncology, 2013
- Stereotactic body radiation therapy: The report of AAPM Task Group 101Medical Physics, 2010
- Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iPlan RT DoseReports of Practical Oncology and Radiotherapy, 2009
- CyberKnife® radiosurgery in the treatment of complex skull base tumors: analysis of treatment planning parametersRadiation Oncology, 2006
- Loss of biological effect in prolonged fraction deliveryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002