Abstract
Conventional active zero-state PWM (AZSPWM) techniques are effective in limiting common-mode voltage (CMV) but typically assume linear and balanced three-phase filter inductances. In practice, however, filter inductors are designed for high-power density and inevitably operate near magnetic saturation (e.g., using powder-core materials). This results in periodic unbalanced dynamic inductances among the three phases and thereby degrading the effectiveness of the well-established pulsewidth modulation (PWM) techniques for CMV reduction. This paper reveals the failure of existing PWM techniques on CMV reduction under such conditions and proposes a saturation-aware selective AZSPWM method that adaptively selects the optimal pair of opposite active vectors based on predicted CMV. A common-mode equivalent circuit incorporating unbalanced dynamic inductances is derived, and an online CMV estimation framework is developed using an approximated $B-H$ curve of the inductor to enable optimal AZSPWM selection. Experimental results on a 220 kVA grid-connected industrial inverter demonstrate that the proposed method significantly reduces CMV compared with conventional AZSPWM method, particularly under the high load and high power factor conditions.
Funding Information
  • Korea Institute of Energy Technology Evaluation and Planning (KETEP) through the Ministry of Climate
  • Energy and Environment (20224000000160)
  • Energy and Environment (RS-2023-00233148)