Shenghui Cui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shenghui Cui has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Jung Jung
School of Electronic and Electrical Engineering, Kyungpook National University, Daegu, Republic of Korea
14 shared publications - Jaeyeon Park
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
7 shared publications - Seung-Ki Sul
Seoul National University, Seoul, South Korea
7 shared publications - Rik W. De Doncker
Institute for Power Generation and Storage Systems, E.ON Energy Research Center, RWTH Aachen University, Aachen, Germany
6 shared publications - Dong-Joon Kim
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
5 shared publications - Junyeol Maeng
Department of Electrical and Computer Engineering and SNU Electric Power Research Institute, Seoul National University, Seoul, South Korea
5 shared publications
Latest Publications
- 20 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16522-16537
Selective Active Zero-State Pulse-Width Modulation for Reduction of Common-Mode Voltage of Three-Phase Inverter Considering Saturation of Filter Inductor
Conventional active zero-state PWM (AZSPWM) techniques are effective in limiting common-mode voltage (CMV) but typically assume linear and balanced three-phase filter inductances. In practice, however, filter inductors are designed for high-power density and inevitably operate near magnetic saturation (e.g., using powder-core materials). This results in periodic unbalanced dynamic inductances among the three phases and thereby degrading the effectiveness of the well-established pulsewidth modulation (PWM) techniques for CMV reduction. This paper reveals the failure of existing PWM techniques on CMV reduction under such conditions and proposes a saturation-aware selective AZSPWM method that adaptively selects the optimal pair of opposite active vectors based on predicted CMV. A common-mode equivalent circuit incorporating unbalanced dynamic inductances is derived, and an online CMV estimation framework is developed using an approximated $B-H$ curve of the inductor to enable optimal AZSPWM selection. Experimental results on a 220 kVA grid-connected industrial inverter demonstrate that the proposed method significantly reduces CMV compared with conventional AZSPWM method, particularly under the high load and high power factor conditions.
- 20 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16522-16537
Selective Active Zero-State Pulse-Width Modulation for Reduction of Common-Mode Voltage of Three-Phase Inverter Considering Saturation of Filter Inductor
Conventional active zero-state PWM (AZSPWM) techniques are effective in limiting common-mode voltage (CMV) but typically assume linear and balanced three-phase filter inductances. In practice, however, filter inductors are designed for high-power density and inevitably operate near magnetic saturation (e.g., using powder-core materials). This results in periodic unbalanced dynamic inductances among the three phases and thereby degrading the effectiveness of the well-established pulsewidth modulation (PWM) techniques for CMV reduction. This paper reveals the failure of existing PWM techniques on CMV reduction under such conditions and proposes a saturation-aware selective AZSPWM method that adaptively selects the optimal pair of opposite active vectors based on predicted CMV. A common-mode equivalent circuit incorporating unbalanced dynamic inductances is derived, and an online CMV estimation framework is developed using an approximated $B-H$ curve of the inductor to enable optimal AZSPWM selection. Experimental results on a 220 kVA grid-connected industrial inverter demonstrate that the proposed method significantly reduces CMV compared with conventional AZSPWM method, particularly under the high load and high power factor conditions.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16503-16521
Improved Decoupled Control of Modular Multilevel Converter Under Constraint of Nearest Level Modulation via Disturbance Observer Design
Nearest level modulation is widely used in modular multilevel converters (MMCs) for its simplicity, but it introduces significant quantization effects on arm-voltage synthesis when the number of submodules (SMs) is small, as in medium-voltage applications. Although the indirect modulation method enables fully decoupled control of ac-side current, dc-side current, and SM capacitor energy, its performance relies on accurate arm voltage synthesis, making it incompatible with the large quantization errors induced by NLM. To address this challenge, this paper proposes a disturbance observer (DOB)-based compensation scheme, which is integrated into the indirect modulation framework. The proposed method compensates for the arm voltage synthesis error as a disturbance, thereby restoring the decoupled control performance of the indirect-modulated MMC without modifying the NLM and decoupled control structure, which is easy to implement. The validity and effectiveness of the proposed method in improving current quality and decoupled control performance are verified through both simulation and experimental results.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 16503-16521
Improved Decoupled Control of Modular Multilevel Converter Under Constraint of Nearest Level Modulation via Disturbance Observer Design
Nearest level modulation is widely used in modular multilevel converters (MMCs) for its simplicity, but it introduces significant quantization effects on arm-voltage synthesis when the number of submodules (SMs) is small, as in medium-voltage applications. Although the indirect modulation method enables fully decoupled control of ac-side current, dc-side current, and SM capacitor energy, its performance relies on accurate arm voltage synthesis, making it incompatible with the large quantization errors induced by NLM. To address this challenge, this paper proposes a disturbance observer (DOB)-based compensation scheme, which is integrated into the indirect modulation framework. The proposed method compensates for the arm voltage synthesis error as a disturbance, thereby restoring the decoupled control performance of the indirect-modulated MMC without modifying the NLM and decoupled control structure, which is easy to implement. The validity and effectiveness of the proposed method in improving current quality and decoupled control performance are verified through both simulation and experimental results.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 12628-12633
Transient Stability Analysis of Grid-Forming Converters With an Elliptical Current Limiter Under Asymmetrical Grid Faults
Under asymmetrical faults, analyzing the transient stability of grid-forming voltage-source converters (GFM-VSCs) becomes essential because their behavior fundamentally differs from that under symmetrical faults. In particular, the point-of-common-coupling voltage of a GFM-VSC contains both positive- and negative-sequence components, and the interaction between these components generates a non-negligible negative-sequence-driven active power. However, the transient stability of GFM-VSCs under asymmetrical faults has not been sufficiently investigated, and the influence of negative-sequence-driven active power remains unclear. Accordingly, this letter derives the $P$-$\delta$ curve of a GFM-VSC with an elliptical current limiter under asymmetrical faults by explicitly accounting for negative-sequence effects. This enables a more accurate transient stability assessment when extending conventional symmetrical-fault analyses to asymmetrical conditions. The theoretical analysis is validated by the agreement between the derived $P$-$\delta$ curve and both simulation and experimental results.
- 16 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 12628-12633
Transient Stability Analysis of Grid-Forming Converters With an Elliptical Current Limiter Under Asymmetrical Grid Faults
Under asymmetrical faults, analyzing the transient stability of grid-forming voltage-source converters (GFM-VSCs) becomes essential because their behavior fundamentally differs from that under symmetrical faults. In particular, the point-of-common-coupling voltage of a GFM-VSC contains both positive- and negative-sequence components, and the interaction between these components generates a non-negligible negative-sequence-driven active power. However, the transient stability of GFM-VSCs under asymmetrical faults has not been sufficiently investigated, and the influence of negative-sequence-driven active power remains unclear. Accordingly, this letter derives the $P$-$\delta$ curve of a GFM-VSC with an elliptical current limiter under asymmetrical faults by explicitly accounting for negative-sequence effects. This enables a more accurate transient stability assessment when extending conventional symmetrical-fault analyses to asymmetrical conditions. The theoretical analysis is validated by the agreement between the derived $P$-$\delta$ curve and both simulation and experimental results.
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14777-14791
Instantaneous Pulse Pattern Control of Three-Phase Multiactive Bridge DC–DC Converters
A three-phase multi-active bridge (MAB3) converter is a multiport dc-dc converter for high power applications. Its three-phase multi-winding transformer enables flexible power flow between multiple dc sources, offering superior high power density and efficiency. However, when fixed duty cycles are employed with mismatched dc voltage conditions, the efficiency of the MAB3 deteriorates, particularly in light-load conditions. To address this, modulation schemes with variable duty cycles are needed, along with dynamic control. However, few studies have explored dynamic control methods compatible with such multi-variable modulations. Without proper dynamic control, step changes in voltage patterns can induce transient overcurrents and transformer flux saturation, limiting the achievable power slew rate. Consequently, mitigating this poor dynamic performance may necessitate transformer overdesign or larger DC-link capacitance. To overcome these challenges, this article proposes an instantaneous pulse pattern control (IPPC) to support generic modulations of MAB3 converters. By formulating dynamic control as a multi-flux regulation problem, the IPPC enables to accommodate the generic modulation schemes while achieving consistent and minimized transient times. Experimental results demonstrate that the proposed IPPC consistently reduces transient times to a single sampling period, equivalent to one sixth of the switching period.
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14777-14791
Instantaneous Pulse Pattern Control of Three-Phase Multiactive Bridge DC–DC Converters
A three-phase multi-active bridge (MAB3) converter is a multiport dc-dc converter for high power applications. Its three-phase multi-winding transformer enables flexible power flow between multiple dc sources, offering superior high power density and efficiency. However, when fixed duty cycles are employed with mismatched dc voltage conditions, the efficiency of the MAB3 deteriorates, particularly in light-load conditions. To address this, modulation schemes with variable duty cycles are needed, along with dynamic control. However, few studies have explored dynamic control methods compatible with such multi-variable modulations. Without proper dynamic control, step changes in voltage patterns can induce transient overcurrents and transformer flux saturation, limiting the achievable power slew rate. Consequently, mitigating this poor dynamic performance may necessitate transformer overdesign or larger DC-link capacitance. To overcome these challenges, this article proposes an instantaneous pulse pattern control (IPPC) to support generic modulations of MAB3 converters. By formulating dynamic control as a multi-flux regulation problem, the IPPC enables to accommodate the generic modulation schemes while achieving consistent and minimized transient times. Experimental results demonstrate that the proposed IPPC consistently reduces transient times to a single sampling period, equivalent to one sixth of the switching period.
- Top Cited PapersOpen Access
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 822-842
Power Hardware-in-the-Loop for Electrical Systems: From Research Experience to Guidelines for Industrial Testing
Power Hardware-In-the-Loop (PHIL) testing is a powerful approach that combines the flexibility of numerical simulations with the high fidelity of hardware tests to allow experimental validation of electrical equipment in a close-to-reality laboratory environment. This is enabled by using specially designed software and hardware that serve as an interface between the modeled environment and the equipment under test. Using PHIL for testing and validation can help significantly reduce time-to-market for novel energy solutions by both reducing the number of design/prototyping iterations, which in turn reduces the development costs, and the need for timely and costly field tests later during the system validation stage. The PHIL as a technology has been studied over the last 20 years, focusing mostly on the software/hardware interfaces and on system stability challenges. However, there has not been a consensus yet on how a PHIL system should be designed, validated and operated to maximize its benefits. The present work provides answers to these questions. Starting from the existing research experience and use cases, the present paper introduces practical guidelines for PHIL modeling, design, laboratory implementation and validation, and it identifies a few remaining open topics that need to be addressed to enable wider adoption of PHIL for testing and validation of electrical equipment in industrial environments.
- 20 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 822-842
Top Cited PapersOpen AccessPower Hardware-in-the-Loop for Electrical Systems: From Research Experience to Guidelines for Industrial Testing
Power Hardware-In-the-Loop (PHIL) testing is a powerful approach that combines the flexibility of numerical simulations with the high fidelity of hardware tests to allow experimental validation of electrical equipment in a close-to-reality laboratory environment. This is enabled by using specially designed software and hardware that serve as an interface between the modeled environment and the equipment under test. Using PHIL for testing and validation can help significantly reduce time-to-market for novel energy solutions by both reducing the number of design/prototyping iterations, which in turn reduces the development costs, and the need for timely and costly field tests later during the system validation stage. The PHIL as a technology has been studied over the last 20 years, focusing mostly on the software/hardware interfaces and on system stability challenges. However, there has not been a consensus yet on how a PHIL system should be designed, validated and operated to maximize its benefits. The present work provides answers to these questions. Starting from the existing research experience and use cases, the present paper introduces practical guidelines for PHIL modeling, design, laboratory implementation and validation, and it identifies a few remaining open topics that need to be addressed to enable wider adoption of PHIL for testing and validation of electrical equipment in industrial environments.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10324-10342
Fault-Tolerant Independent Pole Control Scheme of Zigzag MMC for Bipolar MVDC Distribution Systems
This article presents a fault-tolerant independent pole control scheme for a zigzag modular multilevel converter (MMC) targeting bipolar medium-voltage direct-current (MVDC) distribution systems. An MMC which adopts a zigzag transformer as an ac grid interface transformer, namely zigzag MMC, has inherent bipole operation capability with unbalanced loads of positive and negative poles on the dc side. Nevertheless, this topology has not been thoroughly investigated for its ability to maintain independent control of each pole in the case of a fault in the other. With a conventional MMC control which relies on normal operation of both poles, a fault in a single pole is likely to impact the overall operation of the converter. To tackle this problem, the proposed control scheme separates the arm current controllers and energy balancing controllers within upper and lower arms individually. Additional power reference coupling is introduced to indirectly inject circulating currents when both poles are healthy like the conventional MMC. When a single pole fault occurs, a seamless energy-balancing mode transition can be achieved by modifying inputs to current reference calculators. An ac-side single line-to-ground (SLG) fault ride through strategy can also be integrated without compromising the independence of both poles. A point-to-point zigzag-MMC based bipolar MVDC distribution system is tested by controller hardware-in-the-loop est setup. The test results under single pole-to-ground fault and ac SLG fault validate the effectiveness of the proposed control scheme. Moreover, experimental results using a downscaled MMC prototype and a zigzag transformer further demonstrate the performance of the proposed control scheme under abrupt single-pole blocking and ac SLG fault conditions.
- 16 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10324-10342
Fault-Tolerant Independent Pole Control Scheme of Zigzag MMC for Bipolar MVDC Distribution Systems
This article presents a fault-tolerant independent pole control scheme for a zigzag modular multilevel converter (MMC) targeting bipolar medium-voltage direct-current (MVDC) distribution systems. An MMC which adopts a zigzag transformer as an ac grid interface transformer, namely zigzag MMC, has inherent bipole operation capability with unbalanced loads of positive and negative poles on the dc side. Nevertheless, this topology has not been thoroughly investigated for its ability to maintain independent control of each pole in the case of a fault in the other. With a conventional MMC control which relies on normal operation of both poles, a fault in a single pole is likely to impact the overall operation of the converter. To tackle this problem, the proposed control scheme separates the arm current controllers and energy balancing controllers within upper and lower arms individually. Additional power reference coupling is introduced to indirectly inject circulating currents when both poles are healthy like the conventional MMC. When a single pole fault occurs, a seamless energy-balancing mode transition can be achieved by modifying inputs to current reference calculators. An ac-side single line-to-ground (SLG) fault ride through strategy can also be integrated without compromising the independence of both poles. A point-to-point zigzag-MMC based bipolar MVDC distribution system is tested by controller hardware-in-the-loop est setup. The test results under single pole-to-ground fault and ac SLG fault validate the effectiveness of the proposed control scheme. Moreover, experimental results using a downscaled MMC prototype and a zigzag transformer further demonstrate the performance of the proposed control scheme under abrupt single-pole blocking and ac SLG fault conditions.
- Open Access
- 19 December 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
A fast IVS controller for grid-forming converters: Reducing the current-limiting period to enhance transient stability
- 19 December 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
Open AccessA fast IVS controller for grid-forming converters: Reducing the current-limiting period to enhance transient stability
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8409-8427
Partial Power-Hardware-in-the-Loop Test for In-Situ Dynamic and Steady-State Validation of a Single Submodule in a Megawatt-Scale MMC
Modular multilevel converter (MMC) has been highlighted as a scalable power converter for high-power applications. As a unit power block, submodule (SM) is a key component to achieve the scalability and reliability of the MMC. Therefore, it is important to test an SM under various operating conditions during the development stage before the final full assembly. To reduce the development cost and time, various methods have been presented to test a single SM without a full MMC assembly. Recently, owing to the advancement of processing power, real-time simulators are beginning to be incorporated to test an MMC controller as a controller-hardware-in-the-loop-simulation. This article proposes the realization of a versatile powering test scheme for a single SM combining a real-time simulator, referred to as partial power-hardware-in-the-loop (partial PHIL) test. For demonstration, an industrial SM for a 5 MW MMC-based motor drive system is tested using the partial PHIL test with full-scale voltage and current levels. Various operating conditions are considered, including initial boosting operation, magnetization of the induction motor at standstill, full-load operation, and a step change in speed reference.
- 10 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8409-8427
Partial Power-Hardware-in-the-Loop Test for In-Situ Dynamic and Steady-State Validation of a Single Submodule in a Megawatt-Scale MMC
Modular multilevel converter (MMC) has been highlighted as a scalable power converter for high-power applications. As a unit power block, submodule (SM) is a key component to achieve the scalability and reliability of the MMC. Therefore, it is important to test an SM under various operating conditions during the development stage before the final full assembly. To reduce the development cost and time, various methods have been presented to test a single SM without a full MMC assembly. Recently, owing to the advancement of processing power, real-time simulators are beginning to be incorporated to test an MMC controller as a controller-hardware-in-the-loop-simulation. This article proposes the realization of a versatile powering test scheme for a single SM combining a real-time simulator, referred to as partial power-hardware-in-the-loop (partial PHIL) test. For demonstration, an industrial SM for a 5 MW MMC-based motor drive system is tested using the partial PHIL test with full-scale voltage and current levels. Various operating conditions are considered, including initial boosting operation, magnetization of the induction motor at standstill, full-load operation, and a step change in speed reference.