Evaluation of Individual T1w-DIXON Contrasts for Subtraction Generation in Dynamic Contrast-Enhanced Breast MRI
Open Access
- 12 April 2026
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 16 (8) , 1145
Abstract
Background/Objectives: To evaluate the influence of different DIXON contrasts on the quality of subtraction images in dynamic breast MRI using maximum intensity projections (MIPs). Methods: This retrospective study included n = 40 women (median age: 53.5 years, range 23–83) undergoing clinically indicated breast MRI (3T). For each MRI examination, two independent readers individually evaluated GBCA-enhanced subtraction MIPS for different timepoints (n = 5) and DIXON contrasts (n = 4) per breast, resulting in a total of 800 individual evaluations. Evaluations comprised (a) qualitative measures, using Likert-scores for artefact strength, breast parenchyma visibility, lesion visibility and reading confidence; and (b) signal intensity, measured in three regions of interest with the apparent signal-to-noise ratio (aSNR) and apparent contrast-to-noise ratio (aCNR) calculated. The evaluation results were analysed to identify differences between DIXON contrasts. Results: The “only water” DIXON contrast at ~120s after GBCA injection achieved the highest lesion conspicuity and reading confidence scores and lowest artefact scores; however, its performance was not statistically significant (p > 0.05) compared to the “in-phase” and “opposed-phase” subtractions. The aCNR at the second timepoint was slightly, but not significantly (p > 0.05), lower than the first timepoint, whilst aSNR increased significantly from the first to second timepoint in all contrasts. Conclusions: Subtraction MIPs derived from the “only water” DIXON contrast achieved the highest qualitative scoring for lesion conspicuity and confidence, with the aSNR increasing and aCNR decreasing between the first and second timepoints.Keywords
This publication has 34 references indexed in Scilit:
- Current and future burden of breast cancer: Global statistics for 2020 and 2040The Breast, 2022
- Automated artifact detection in abbreviated dynamic contrast-enhanced (DCE) MRI-derived maximum intensity projections (MIPs) of the breastEuropean Radiology, 2022
- Background parenchymal enhancement on breast MRI: A comprehensive reviewJournal of Magnetic Resonance Imaging, 2019
- Abbreviated MRI of the Breast: Does It Provide Value?Journal of Magnetic Resonance Imaging, 2018
- Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS techniqueDiagnostic and Interventional Imaging, 2018
- Fat suppression techniques for breast MRI: Dixon versus spectral fat saturation for 3D T1-weighted at 3 TLa radiologia medica, 2017
- Abbreviated Screening Protocol for Breast MRIAcademic Radiology, 2015
- Water/fat‐resolved whole‐heart Dixon coronary MRA: An initial comparisonMagnetic Resonance in Medicine, 2013
- T1‐weighted 3D dynamic contrast‐enhanced MRI of the breast using a dual‐echo dixon technique at 3 TJournal of Magnetic Resonance Imaging, 2011
- Measurement of Signal-to-Noise and Contrast-to-Noise in the fBIRN Multicenter Imaging StudyJournal of Digital Imaging, 2006