    Optimization Design of Shielding Cover for Valve-Side Bushings Considering Interface Charge and Electric Field Distributions

    by Minjie Li, Gaoyi Shang, WanHao SHI, Hao Sun, Xueyang Bai, Hao Tang, Yi Zhang, Xuandong Liu

    Frequent gas-solid interface flashover accidents on valve-side bushings seriously threaten the safe operation of ultra-high voltage direct current (UHVDC) systems. However, optimizing their shielding cover structures still lacks systematic theoretical support. This paper establishes a electric-thermal-ion transport multi-physics coupled model of ±800 kV valve-side bushing. The influence mechanism of the shield cover structure (width, gap distance, and chamfer radius) on charge accumulation and electric field distortion at the core end is studied. Results show that the shield width is the dominant parameter affecting the charge and electric field peaks at the core end. Broadening width from 50 mm to 80 mm suppresses them by over 40% and the peak electric field shift toward the long surface. However, once the electric field peak fully appears on the long surface, further widening offers limited benefit. Meanwhile, gap distance and chamfer radius act locally, suppressing charge density and electric field at gap surface while rebounding the peaks at corner arc. Based on these variation law, a dimensionless design criterion incorporating a corner arc concentration factor (Kc) and a gap non-uniformity factor (Kgap) are proposed, which translate complex electric variation trends into empirical formulas. Ultimately, the optimal shield dimensions for a ±800 kV bushing are identified as w = 80 mm, d = 5–8 mm, and r = 5–30 mm.

  • Open Access

    Fast computation of electro-thermal-ion transport coupling field of ±800 kV valve-side bushing based on improved SUPG method

    by Minjie Li, Hao Sun, Gaoyi Shang, WanHao SHI, Xueyang Bai, Hao Tang, Yi Zhang, Xuandong Liu

    The flashover faults of gas-solid interface of converter transformer valve-side bushing have occurred frequently in recent years. However, the existing electro-thermal-ion transport multi-physics coupling model used to guide engineering applications have a poor convergence performance and excessive computational time. This paper first establishes a electro-ion transport model of a scaled-down bushing, and the streamline upwind Petrov–Galerkin (SUPG) method is employed to stabilize the ion convection-diffusion equation. A corresponding experimental platform is built to validate the simulation results. On this basis, an electro-thermal-ion transport multi-physics coupling model of the ±800 kV valve-side bushing is established, and the SUPG method is reformulated and solved in the form of weak-form partial differential equation (PDE). The results show that the PDE can obtain computational results more accurately and faster than the traditional formulation, reducing computational memory and time by 60% and 90%, respectively. Notably, many terms in the PDE have negligible influence on the final results. Based on this observation, a simplified SUPG method is proposed, which further reduces memory usage by 30.20% and computation time by 52.18% while completely preserving the accuracy of the results. Finally, the proposed method is applied to calculate the transient charge and electric field distribution of gas-solid interface of ±800 kV valve-side bushing, achieving satisfactory computational efficiency and accuracy