Image Quality and Quantitative PET Parameters of Low-Dose [18F]FDG PET in a Long Axial Field-of-View PET/CT Scanner
Authors:
- Eduardo CalderónECEduardo Calderón
- Fabian P. SchmidtFSFabian P. Schmidt
- Wenhong LanWLWenhong Lan
- Salvador Castaneda-VegaSCSalvador Castaneda-Vega
- Andreas S. BrendlinABAndreas S. Brendlin
- Nils F. TrautweinNTNils F. Trautwein
- Helmut DittmannHDHelmut Dittmann
- Christian la FougèreCFChristian la Fougère
- Lena Sophie KieferLKLena Sophie Kiefer
Open Access
- 18 October 2023
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 13 (20) , 3240
Abstract
PET/CT scanners with a long axial field-of-view (LAFOV) provide increased sensitivity, enabling the adjustment of imaging parameters by reducing the injected activity or shortening the acquisition time. This study aimed to evaluate the limitations of reduced [18F]FDG activity doses on image quality, lesion detectability, and the quantification of lesion uptake in the Biograph Vision Quadra, as well as to assess the benefits of the recently introduced ultra-high sensitivity mode in a clinical setting. A number of 26 patients who underwent [18F]FDG-PET/CT (3.0 MBq/kg, 5 min scan time) were included in this analysis. The PET raw data was rebinned for shorter frame durations to simulate 5 min scans with lower activities in the high sensitivity (HS) and ultra-high sensitivity (UHS) modes. Image quality, noise, and lesion detectability (n = 82) were assessed using a 5-point Likert scale. The coefficient of variation (CoV), signal-to-noise ratio (SNR), tumor-to-background ratio (TBR), and standardized uptake values (SUV) including SUVmean, SUVmax, and SUVpeak were evaluated. Subjective image ratings were generally superior in UHS compared to the HS mode. At 0.5 MBq/kg, lesion detectability decreased to 95% (HS) and to 98% (UHS). SNR was comparable at 1.0 MBq/kg in HS (5.7 ± 0.6) and 0.5 MBq/kg in UHS (5.5 ± 0.5). With lower doses, there were negligible reductions in SUVmean and SUVpeak, whereas SUVmax increased steadily. Reducing the [18F]FDG activity to 1.0 MBq/kg (HS/UHS) in a LAFOV PET/CT provides diagnostic image quality without statistically significant changes in the uptake parameters. The UHS mode improves image quality, noise, and lesion detectability compared to the HS mode.Keywords
All Related Versions
Funding Information
- Deutsche Forschungsgemeinschaft (INST 37/1145-1 FUGG, EXC 2180—390900677, 2727-0-0)
- Faculty of Medicine, Tuebingen, Germany (INST 37/1145-1 FUGG, EXC 2180—390900677, 2727-0-0)
This publication has 37 references indexed in Scilit:
- FDG PET/CT in the Staging of Lung CancerCurrent Radiopharmaceuticals, 2020
- Measurement of the branching ratio related to the internal pair production of Y-90Applied Radiation and Isotopes, 2020
- Reduction of 18F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier DetectorsRadiology, 2018
- Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient CareJournal of Nuclear Medicine, 2017
- Technical note: how to determine the FDG activity for tumour PET imaging that satisfies European guidelinesEJNMMI Physics, 2016
- ICRP Publication 128: Radiation Dose to Patients from Radiopharmaceuticals: a Compendium of Current Information Related to Frequently Used SubstancesAnnals of the ICRP, 2015
- FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0European Journal of Nuclear Medicine and Molecular Imaging, 2014
- Quantitative and Qualitative Assessment of Yttrium-90 PET/CT ImagingPLOS ONE, 2014
- Noise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake ValueJournal of Nuclear Medicine, 2012
- Application and Evaluation of a Measured Spatially Variant System Model for PET Image ReconstructionIEEE Transactions on Medical Imaging, 2010