Toward Real-Time Pose Estimation of the Mitral Valve Robot Under C-Arm X-Ray Fluoroscopy
- 22 October 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 928-935
Abstract
Mitral regurgitation (MR) is a condition caused by a deformity in the mitral valve leading to the backflow of blood into the left atrium. MR can be treated through a minimally invasive procedure and our lab is currently developing a robot that could potentially be used to treat MR. The robot would carry a clip that latches onto the valve’s leaflets and closes them to minimize leakage. The robot’s accurate localization is needed to navigate the clip to the leaflets successfully. This paper discusses algorithms used to track the clip’s position and orientation under real-time using C-arm fluoroscopy. The positions are found through a deep learning semantic segmentation framework and the pose is found by calculating its bending and rotational angles. The robot’s bending angle and the clip’s rotational angle is found through an equivalent ellipse algorithm and an SVM classifier, respectively, and were validated by comparing orientations obtained from an electromagnetic tracker. The bending angle calculation has an average error of 7.7° and the rotational angle calculation is 76% for classifying them into five classes. Execution times are within 100ms and hence this could be a promising approach in real-time pose estimation.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01HL140325)
This publication has 34 references indexed in Scilit:
- Jaccard index compensation for object segmentation evaluation2014
- Minimally invasive approach provides at least equivalent results for surgical correction of mitral regurgitation: A propensity-matched comparisonThe Journal of Thoracic and Cardiovascular Surgery, 2013
- Technical review of the da Vinci surgical telemanipulatorThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interactionMedical Image Analysis, 2007
- Burden of valvular heart diseases: a population-based studyThe Lancet, 2006
- Characteristics of hand motion of eye surgeons2002
- Fluoroscopy2002
- Manual control and tracking—a human factor analysis relevant for beating heart surgeryThe Annals of Thoracic Surgery, 2002
- Prevalence and clinical determinants of mitral, tricuspid, and aortic regurgitation (the Framingham Heart Study)The American Journal of Cardiology, 1999
- A Robust Method for Multiple Linear RegressionTechnometrics, 1974