Candidemia in patients with cardiovascular implantable electronic devices
- 11 February 2020
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 60 (1) , 69-75
Abstract
Purpose Current guidelines recommend complete extraction of cardiovascular implantable electronic devices (CIEDs) in the case of persistent or recurrent fungemia without other identifiable sources, though supporting evidence is lacking. We sought to evaluate the prognosis of patients with candidemia and CIEDs. Methods Twelve consecutive patients (54 ± 12 years, 8 male) with CIED and concurrent candidemia were reviewed. Results At the time of diagnosis with candidemia, seven patients were immunocompromised, six were on long-term antibacterial therapy, two were intravenous drug users, four were on chronic hemodialysis, and six had a central venous catheter. Four patients were confirmed as definite CIED infection as vegetation was visible on lead by echocardiogram. The other 8 patients were considered possible CIED infection with candidemia of unknown focus. All patients with visible vegetation underwent CIED removal without complications, and other patients were initially managed non-operatively. After 1 year of follow-up, 7 patients had died and at extended follow-up, all patients without lead removal died while 3 of 4 patients with lead extraction survived. Of note, 50% of deaths in the patients without lead removal were associated with fungal sepsis. Conclusions Candida fungemia is associated with a high mortality. CIED removal should be an early consideration in these patients even if lead vegetations are not seen.Keywords
Funding Information
- CTSA (UL1 TR002243)
This publication has 31 references indexed in Scilit:
- Cardiovascular Implantable Electronic Device Infections in Left Ventricular Assist Device RecipientsPacing and Clinical Electrophysiology, 2013
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- Outcomes in Patients With Cardiovascular Implantable Electronic Devices and Bacteremia Caused by Gram-Positive Cocci Other Than Staphylococcus AureusCirculation: Arrhythmia and Electrophysiology, 2010
- Cardiovascular Implantable Electronic Device Infection in Patients withStaphylococcus aureusBacteremiaPacing and Clinical Electrophysiology, 2010
- Candida endocarditis associated with cardiac rhythm management devices: review with current treatment guidelinesMycoses, 2010
- Candida Infective EndocarditisMedicine, 2009
- Candida endocarditis: role of new antifungal agentsMycoses, 2008
- Biofilm Production by Candida Species and Inadequate Antifungal Therapy as Predictors of Mortality for Patients with CandidemiaJournal of Clinical Microbiology, 2007
- Fungal infection of implantable cardioverter-defibrillators: Case series of five patients managed over 22 yearsHeart Rhythm, 2006
- Candida biofilmsCurrent Opinion in Microbiology, 2002