Zhixing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhixing Wang has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
- Congyu Liao
Department of Radiology and Biomedical Imaging University of California San Francisco California USA
4 shared publications John P. Mugler
Department of Biomedical Engineering University of Virginia Charlottesville Virginia USA
4 shared publicationsKawin Setsompop
Department of Radiology Stanford University Stanford California USA
4 shared publications- Adrienne E. Campbell-Washburn
Cardiovascular Branch, Division of Intramural Research National Heart, Lung, and Blood Institute, National Institutes of Health Bethesda Maryland USA
3 shared publications - Craig H. Meyer
Department of Biomedical Engineering University of Virginia Charlottesville Virginia USA
3 shared publications Nan Wang
Department of Radiology Stanford University Stanford California USA
3 shared publications
Latest Publications
- 10 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3594-3607
A Dynamic Shim Approach for Correcting Eddy Current Effects in Diffusion‐Prepared MRI Acquisition Using a Multi‐Coil AC / DC Shim‐Array
Purpose: We developed a dynamic B 0 shimming approach using a 46‐channel AC/DC shim array to correct phase errors caused by eddy currents from diffusion‐encoding gradients in diffusion‐prepared MRI, enabling high b value imaging without the SNR loss from the use of a magnitude stabilizer. Methods: A 46‐channel AC/DC shim array and corresponding amplifier system were built. Spin echo prescans with and without diffusion preparation were then used to rapidly measure eddy current–induced phase differences. These phase maps were used as targets in an optimization framework to compute compensatory shim currents for multi‐shot 3D diffusion‐prepared acquisitions. Results: The proposed method allows flexible use of the AC/DC shim array to correct undesirable eddy current effects in diffusion‐prepared MRI. Phantom and in vivo experiments demonstrate whole‐brain, cardiac‐gated, multi‐shot 3D diffusion‐prepared imaging without the use of magnitude stabilizers. The approach enables preservation of full SNR while achieving reliable diffusion encoding at b values up to 2000 s/mm 2 . Conclusions: This work demonstrates a new strategy for applying an AC/DC shim array to compensate for eddy current–induced phase errors in diffusion‐prepared MRI. By eliminating the need for a magnitude stabilizer, it enables efficient high‐quality diffusion imaging with full signal sensitivity retained.
- 10 February 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (6) , 3594-3607
A Dynamic Shim Approach for Correcting Eddy Current Effects in Diffusion‐Prepared MRI Acquisition Using a Multi‐Coil AC / DC Shim‐Array
Purpose: We developed a dynamic B 0 shimming approach using a 46‐channel AC/DC shim array to correct phase errors caused by eddy currents from diffusion‐encoding gradients in diffusion‐prepared MRI, enabling high b value imaging without the SNR loss from the use of a magnitude stabilizer. Methods: A 46‐channel AC/DC shim array and corresponding amplifier system were built. Spin echo prescans with and without diffusion preparation were then used to rapidly measure eddy current–induced phase differences. These phase maps were used as targets in an optimization framework to compute compensatory shim currents for multi‐shot 3D diffusion‐prepared acquisitions. Results: The proposed method allows flexible use of the AC/DC shim array to correct undesirable eddy current effects in diffusion‐prepared MRI. Phantom and in vivo experiments demonstrate whole‐brain, cardiac‐gated, multi‐shot 3D diffusion‐prepared imaging without the use of magnitude stabilizers. The approach enables preservation of full SNR while achieving reliable diffusion encoding at b values up to 2000 s/mm 2 . Conclusions: This work demonstrates a new strategy for applying an AC/DC shim array to compensate for eddy current–induced phase errors in diffusion‐prepared MRI. By eliminating the need for a magnitude stabilizer, it enables efficient high‐quality diffusion imaging with full signal sensitivity retained.
- 30 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2611-2626
In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner
Purpose: To push the speed and resolution limit of in vivo quantitative imaging and enable estimation of quantitative tissue parameters of subtle brain structures that were previously difficult to assess. Methods: This study implemented an efficient quantitative imaging approach, 3D‐SPI MRF, on the NexGen 7T scanner equipped with a high‐performance head‐only gradient and 96‐channel receiver array. To address challenges associated with performing rapid mesoscale MRF on this system, acquisition and reconstruction mitigation methods were developed and incorporated into the MRF framework, including: (i) flip‐angle‐aware dictionary fitting to account for both B 1 + inhomogeneity and voxel‐specific RF frequency response, (ii) gradient imperfection corrections via Skope measurements that incorporates a new per‐TR trajectory rewinder compensation, (iii) incorporation of rapid B 1 + and B 0 mappings into the MRF sequence, and (iv) high‐temporal motion navigation. Results: Whole‐brain T 1 and T 2 maps were obtained at 560‐μm isotropic resolution within 4 min, where ablation studies demonstrated the necessity of the various mitigation methods implemented in removing bias and artifacts. For comparison, MRF data were acquired using current state‐of‐the‐art method but limited to typical whole‐body gradient specifications to demonstrate that the proposed developments resulted in ∼3× shorter scan time while producing more accurate parameter maps. Data were also acquired at ∼3.8× smaller voxel size, 360‐μm isotropic, using the developed technique, to achieve mesoscale multi‐parameter quantitative mapping in vivo. Conclusion: Tailored 3D MRF acquisition and reconstruction were developed to enable fast and accurate T 1 and T 2 mapping across the whole‐brain at mesoscale resolution on the NexGen 7T scanner.
- 30 December 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2611-2626
In Vivo Meso‐Scale Whole‐Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner
Purpose: To push the speed and resolution limit of in vivo quantitative imaging and enable estimation of quantitative tissue parameters of subtle brain structures that were previously difficult to assess. Methods: This study implemented an efficient quantitative imaging approach, 3D‐SPI MRF, on the NexGen 7T scanner equipped with a high‐performance head‐only gradient and 96‐channel receiver array. To address challenges associated with performing rapid mesoscale MRF on this system, acquisition and reconstruction mitigation methods were developed and incorporated into the MRF framework, including: (i) flip‐angle‐aware dictionary fitting to account for both B 1 + inhomogeneity and voxel‐specific RF frequency response, (ii) gradient imperfection corrections via Skope measurements that incorporates a new per‐TR trajectory rewinder compensation, (iii) incorporation of rapid B 1 + and B 0 mappings into the MRF sequence, and (iv) high‐temporal motion navigation. Results: Whole‐brain T 1 and T 2 maps were obtained at 560‐μm isotropic resolution within 4 min, where ablation studies demonstrated the necessity of the various mitigation methods implemented in removing bias and artifacts. For comparison, MRF data were acquired using current state‐of‐the‐art method but limited to typical whole‐body gradient specifications to demonstrate that the proposed developments resulted in ∼3× shorter scan time while producing more accurate parameter maps. Data were also acquired at ∼3.8× smaller voxel size, 360‐μm isotropic, using the developed technique, to achieve mesoscale multi‐parameter quantitative mapping in vivo. Conclusion: Tailored 3D MRF acquisition and reconstruction were developed to enable fast and accurate T 1 and T 2 mapping across the whole‐brain at mesoscale resolution on the NexGen 7T scanner.
- Open Access
Comparative Evaluation of [68Ga]Ga-Fibroblast Activation Protein Inhibitor vs. [18F]FDG as a Novel Radiotracer for Biology-Guided Image Radiotherapy
Background/Objectives: Biology-guided radiotherapy (BgRT) is a novel technology utilizing PET radiotracer emissions to deliver image-guided adaptive RT. 18F-Fluorodeoxyglucose ([18F]FDG) is the most common PET radiotracer but has background in the liver and brain because it is taken up by viable tumor cells as well as inflammatory cells. Fibroblast activation protein (FAP) is overexpressed in cancer-associated fibroblasts with minimal expression in normal tissues. FAP inhibitors (FAPIs) bind to FAP, and a FAPI labeled with Gallium-68 (68Ga) is a novel radiotracer with high tumor selectivity. Multiple studies have compared [68Ga]Ga-FAPI-04 vs. [18F]FDG for diagnostic imaging, but [68Ga]Ga-FAPI-04 vs. [18F]FDG have never been compared in terms of their utility for BgRT. Purpose: This study was designed to assess the utility of [68Ga]Ga-FAPI-04 vs. [18F]FDG for BgRT used to treat pancreatic, liver, lung, head and neck, and cervical cancers. Methods: A radiation oncologist specializing in each cancer contoured the gross tumor volume (GTV) on [18F]FDG PET-CT and [68Ga]Ga-FAPI-04 PET-CT images. Auto-contours were generated using an auto-threshold of 40% of the maximum Standardized Uptake Value (SUV). The suitability of [68Ga]Ga-FAPI-04 vs. [18F]FDG for BgRT was evaluated by comparing Normalized Net Activity Concentration (NNA) and Normalized Target Signal (NTS) for each cancer. Results: NNA and NTS for [68Ga]Ga-FAPI-04 and [18F]FDG met the requirements for [18F]FDG-guided BgRT (NNA > 5.0 kBq/mL, NTS > 2.7) for all disease sites. NNAFAPI was significantly greater than NNAFDG for pancreatic, H&N, and cervical cancer. NTSFAPI was significantly greater than NTSFDG for pancreatic, liver, and lung cancer. Conclusions: [68Ga]Ga-FAPI-04 is a novel radiotracer for BgRT and has the greatest potential impact in the treatment of pancreatic cancer.
Open AccessComparative Evaluation of [68Ga]Ga-Fibroblast Activation Protein Inhibitor vs. [18F]FDG as a Novel Radiotracer for Biology-Guided Image Radiotherapy
Background/Objectives: Biology-guided radiotherapy (BgRT) is a novel technology utilizing PET radiotracer emissions to deliver image-guided adaptive RT. 18F-Fluorodeoxyglucose ([18F]FDG) is the most common PET radiotracer but has background in the liver and brain because it is taken up by viable tumor cells as well as inflammatory cells. Fibroblast activation protein (FAP) is overexpressed in cancer-associated fibroblasts with minimal expression in normal tissues. FAP inhibitors (FAPIs) bind to FAP, and a FAPI labeled with Gallium-68 (68Ga) is a novel radiotracer with high tumor selectivity. Multiple studies have compared [68Ga]Ga-FAPI-04 vs. [18F]FDG for diagnostic imaging, but [68Ga]Ga-FAPI-04 vs. [18F]FDG have never been compared in terms of their utility for BgRT. Purpose: This study was designed to assess the utility of [68Ga]Ga-FAPI-04 vs. [18F]FDG for BgRT used to treat pancreatic, liver, lung, head and neck, and cervical cancers. Methods: A radiation oncologist specializing in each cancer contoured the gross tumor volume (GTV) on [18F]FDG PET-CT and [68Ga]Ga-FAPI-04 PET-CT images. Auto-contours were generated using an auto-threshold of 40% of the maximum Standardized Uptake Value (SUV). The suitability of [68Ga]Ga-FAPI-04 vs. [18F]FDG for BgRT was evaluated by comparing Normalized Net Activity Concentration (NNA) and Normalized Target Signal (NTS) for each cancer. Results: NNA and NTS for [68Ga]Ga-FAPI-04 and [18F]FDG met the requirements for [18F]FDG-guided BgRT (NNA > 5.0 kBq/mL, NTS > 2.7) for all disease sites. NNAFAPI was significantly greater than NNAFDG for pancreatic, H&N, and cervical cancer. NTSFAPI was significantly greater than NTSFDG for pancreatic, liver, and lung cancer. Conclusions: [68Ga]Ga-FAPI-04 is a novel radiotracer for BgRT and has the greatest potential impact in the treatment of pancreatic cancer.
- 15 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 41-58
Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T
Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal‐to‐noise ratio is limited by the field strength and k‐space sampling speed is limited by a lower specification gradient system. Methods: We adapted the three‐dimensional spiral projection imaging MR fingerprinting approach to 0.55T scanners, with additional features incorporated to improve the image quality of quantitative brain and musculoskeletal imaging, including (i) improved k‐space sampling efficiency, (ii) Cramér‐Rao lower bound optimized flip‐angle pattern for specified T 1 and T 2 at 0.55 T, (iii) gradient trajectory correction, (iv) attention‐based denoising, and (v) motion estimation and correction. Results: The proposed MRF acquisition and reconstruction framework can provide high‐quality 1.2‐mm isotropic whole‐brain quantitative maps and 1‐mm isotropic knee quantitative maps, each acquired in 4.5 min. The proposed method was validated in both phantom and in vivo brain and knee studies. Conclusion: By proposing novel methods and integrating advanced techniques, we achieved high‐isotropic‐resolution MRF on a 0.55T scanner, demonstrating enhanced efficiency, motion resilience, and quantitative accuracy.
- 15 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 41-58
Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T
Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal‐to‐noise ratio is limited by the field strength and k‐space sampling speed is limited by a lower specification gradient system. Methods: We adapted the three‐dimensional spiral projection imaging MR fingerprinting approach to 0.55T scanners, with additional features incorporated to improve the image quality of quantitative brain and musculoskeletal imaging, including (i) improved k‐space sampling efficiency, (ii) Cramér‐Rao lower bound optimized flip‐angle pattern for specified T 1 and T 2 at 0.55 T, (iii) gradient trajectory correction, (iv) attention‐based denoising, and (v) motion estimation and correction. Results: The proposed MRF acquisition and reconstruction framework can provide high‐quality 1.2‐mm isotropic whole‐brain quantitative maps and 1‐mm isotropic knee quantitative maps, each acquired in 4.5 min. The proposed method was validated in both phantom and in vivo brain and knee studies. Conclusion: By proposing novel methods and integrating advanced techniques, we achieved high‐isotropic‐resolution MRF on a 0.55T scanner, demonstrating enhanced efficiency, motion resilience, and quantitative accuracy.
- Open Access
- 20 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1741-1750
Variable‐flip‐angle 3D spiral‐in‐out turbo spin‐echo imaging using concomitant gradient compensation and echo reordering at 0.55 T
Purpose: To develop single‐slab 3D spiral turbo spin echo (spiral SPACE) for 1‐mm 3 isotropic whole‐brain T 2 ‐weighted imaging on a high‐performance 0.55T scanner, with high scan efficiency from interleaved spiral‐in‐out trajectories, variable‐flip‐angle refocusing radiofrequency (RF) pulses, echo reordering, and concomitant‐field compensation. Methods: A stack‐of‐spirals (in‐out waveforms) turbo‐spin‐echo acquisition was implemented with T 2 ‐weighed contrast. Gradient infidelity was corrected using the gradient impulse response function (GIRF), and concomitant‐field compensation was used to correct for phase errors among echoes and during the readout windows. To maintain a long echo train (˜600 ms) within each shot, variable‐flip‐angle refocusing RF pulses were generated using extended‐phase‐graph analysis. An echo‐reordering scheme provided a smooth signal variation along the echo direction in k‐space. Images from spiral SPACE with and without concomitant‐field compensation were compared with those from Cartesian SPACE in phantoms and 6 healthy volunteers. Results: Phantom results demonstrated the improved performance of concomitant‐field correction via sequence‐based modifications and of GIRF–based trajectory estimation. Volunteer data showed that with concomitant‐field correction and echo reordering, system imperfection associated image artifacts and blurring were substantially mitigated in spiral SPACE. Compared with Cartesian SPACE, spiral SPACE had an overall 15%–25% signal‐to‐noise ratio (SNR) improvement in both white matter and gray matter. Conclusion: A 3D spiral‐in‐out SPACE acquisition with variable‐flip‐angles, concomitant‐field compensation, and echo‐reordering was demonstrated at 0.55 T, showing promising gains in SNR, compared with Cartesian SPACE.
- 20 November 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (4) , 1741-1750
Open AccessVariable‐flip‐angle 3D spiral‐in‐out turbo spin‐echo imaging using concomitant gradient compensation and echo reordering at 0.55 T
Purpose: To develop single‐slab 3D spiral turbo spin echo (spiral SPACE) for 1‐mm 3 isotropic whole‐brain T 2 ‐weighted imaging on a high‐performance 0.55T scanner, with high scan efficiency from interleaved spiral‐in‐out trajectories, variable‐flip‐angle refocusing radiofrequency (RF) pulses, echo reordering, and concomitant‐field compensation. Methods: A stack‐of‐spirals (in‐out waveforms) turbo‐spin‐echo acquisition was implemented with T 2 ‐weighed contrast. Gradient infidelity was corrected using the gradient impulse response function (GIRF), and concomitant‐field compensation was used to correct for phase errors among echoes and during the readout windows. To maintain a long echo train (˜600 ms) within each shot, variable‐flip‐angle refocusing RF pulses were generated using extended‐phase‐graph analysis. An echo‐reordering scheme provided a smooth signal variation along the echo direction in k‐space. Images from spiral SPACE with and without concomitant‐field compensation were compared with those from Cartesian SPACE in phantoms and 6 healthy volunteers. Results: Phantom results demonstrated the improved performance of concomitant‐field correction via sequence‐based modifications and of GIRF–based trajectory estimation. Volunteer data showed that with concomitant‐field correction and echo reordering, system imperfection associated image artifacts and blurring were substantially mitigated in spiral SPACE. Compared with Cartesian SPACE, spiral SPACE had an overall 15%–25% signal‐to‐noise ratio (SNR) improvement in both white matter and gray matter. Conclusion: A 3D spiral‐in‐out SPACE acquisition with variable‐flip‐angles, concomitant‐field compensation, and echo‐reordering was demonstrated at 0.55 T, showing promising gains in SNR, compared with Cartesian SPACE.
- Open Access
- 11 November 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (1) , e5291
MRI denoising with a non‐blind deep complex‐valued convolutional neural network
MR images with high signal‐to‐noise ratio (SNR) provide more diagnostic information. Various methods for MRI denoising have been developed, but the majority of them operate on the magnitude image and neglect the phase information. Therefore, the goal of this work is to design and implement a complex‐valued convolutional neural network (CNN) for MRI denoising. A complex‐valued CNN incorporating the noise level map (non‐blind DnCNN) was trained with ground truth and simulated noise‐corrupted image pairs. The proposed method was validated using both simulated and in vivo data collected from low‐field scanners. Its denoising performance was quantitively and qualitatively evaluated, and it was compared with the real‐valued CNN and several other algorithms. For the simulated noise‐corrupted testing dataset, the complex‐valued models had superior normalized root‐mean‐square error, peak SNR, structural similarity index, and phase ABSD. By incorporating the noise level map, the non‐blind DnCNN showed better performance in dealing with spatially varying parallel imaging noise. For in vivo low‐field data, the non‐blind DnCNN significantly improved the SNR and visual quality of the image. The proposed non‐blind DnCNN provides an efficient and effective approach for MRI denoising. This is the first application of non‐blind DnCNN to medical imaging. The method holds the potential to enable improved low‐field MRI, facilitating enhanced diagnostic imaging in under‐resourced areas.
- 11 November 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (1) , e5291
Open AccessMRI denoising with a non‐blind deep complex‐valued convolutional neural network
MR images with high signal‐to‐noise ratio (SNR) provide more diagnostic information. Various methods for MRI denoising have been developed, but the majority of them operate on the magnitude image and neglect the phase information. Therefore, the goal of this work is to design and implement a complex‐valued convolutional neural network (CNN) for MRI denoising. A complex‐valued CNN incorporating the noise level map (non‐blind DnCNN) was trained with ground truth and simulated noise‐corrupted image pairs. The proposed method was validated using both simulated and in vivo data collected from low‐field scanners. Its denoising performance was quantitively and qualitatively evaluated, and it was compared with the real‐valued CNN and several other algorithms. For the simulated noise‐corrupted testing dataset, the complex‐valued models had superior normalized root‐mean‐square error, peak SNR, structural similarity index, and phase ABSD. By incorporating the noise level map, the non‐blind DnCNN showed better performance in dealing with spatially varying parallel imaging noise. For in vivo low‐field data, the non‐blind DnCNN significantly improved the SNR and visual quality of the image. The proposed non‐blind DnCNN provides an efficient and effective approach for MRI denoising. This is the first application of non‐blind DnCNN to medical imaging. The method holds the potential to enable improved low‐field MRI, facilitating enhanced diagnostic imaging in under‐resourced areas.
- 5 November 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (2) , e5051
High‐resolution spiral real‐time cardiac cine imaging with deep learning‐based rapid image reconstruction and quantification
The objective of the current study was to develop and evaluate a DEep learning‐based rapid Spiral Image REconstruction (DESIRE) and deep learning (DL)‐based segmentation approach to quantify the left ventricular ejection fraction (LVEF) for high‐resolution spiral real‐time cine imaging, including 2D balanced steady‐state free precession imaging at 1.5 T and gradient echo (GRE) imaging at 1.5 and 3 T. A 3D U‐Net–based image reconstruction network and 2D U‐Net–based image segmentation network were proposed and evaluated. Low‐rank plus sparse (L+S) served as the reference for the image reconstruction network and manual contouring of the left ventricle was the reference of the segmentation network. To assess the image reconstruction quality, structural similarity index, peak signal‐to‐noise ratio, normalized root‐mean‐square error, and blind grading by two experienced cardiologists (5: excellent; 1: poor) were performed. To assess the segmentation performance, quantification of the LVEF on GRE imaging at 3 T was compared with the quantification from manual contouring. Excellent performance was demonstrated by the proposed technique. In terms of image quality, there was no difference between L+S and the proposed DESIRE technique. For quantification analysis, the proposed DL method was not different to the manual segmentation method (p > 0.05) in terms of quantification of LVEF. The reconstruction time for DESIRE was ~32 s (including nonuniform fast Fourier transform [NUFFT]) per dynamic series (40 frames), while the reconstruction time of L+S with GPU acceleration was approximately 3 min. The DL segmentation takes less than 5 s. In conclusion, the proposed DL‐based image reconstruction and quantification techniques enabled 1‐min image reconstruction for the whole heart and quantification with automatic reconstruction and quantification of the left ventricle function for high‐resolution spiral real‐time cine imaging with excellent performance.
- 5 November 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 37 (2) , e5051
High‐resolution spiral real‐time cardiac cine imaging with deep learning‐based rapid image reconstruction and quantification
The objective of the current study was to develop and evaluate a DEep learning‐based rapid Spiral Image REconstruction (DESIRE) and deep learning (DL)‐based segmentation approach to quantify the left ventricular ejection fraction (LVEF) for high‐resolution spiral real‐time cine imaging, including 2D balanced steady‐state free precession imaging at 1.5 T and gradient echo (GRE) imaging at 1.5 and 3 T. A 3D U‐Net–based image reconstruction network and 2D U‐Net–based image segmentation network were proposed and evaluated. Low‐rank plus sparse (L+S) served as the reference for the image reconstruction network and manual contouring of the left ventricle was the reference of the segmentation network. To assess the image reconstruction quality, structural similarity index, peak signal‐to‐noise ratio, normalized root‐mean‐square error, and blind grading by two experienced cardiologists (5: excellent; 1: poor) were performed. To assess the segmentation performance, quantification of the LVEF on GRE imaging at 3 T was compared with the quantification from manual contouring. Excellent performance was demonstrated by the proposed technique. In terms of image quality, there was no difference between L+S and the proposed DESIRE technique. For quantification analysis, the proposed DL method was not different to the manual segmentation method (p > 0.05) in terms of quantification of LVEF. The reconstruction time for DESIRE was ~32 s (including nonuniform fast Fourier transform [NUFFT]) per dynamic series (40 frames), while the reconstruction time of L+S with GPU acceleration was approximately 3 min. The DL segmentation takes less than 5 s. In conclusion, the proposed DL‐based image reconstruction and quantification techniques enabled 1‐min image reconstruction for the whole heart and quantification with automatic reconstruction and quantification of the left ventricle function for high‐resolution spiral real‐time cine imaging with excellent performance.
- Open Access
- 25 May 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (6) , 1533
Hyperpolarized Xenon-129: A New Tool to Assess Pulmonary Physiology in Patients with Pulmonary Fibrosis
Purpose: The existing tools to quantify lung function in interstitial lung diseases have significant limitations. Lung MRI imaging using inhaled hyperpolarized xenon-129 gas (129Xe) as a contrast agent is a new technology for measuring regional lung physiology. We sought to assess the utility of the 129Xe MRI in detecting impaired lung physiology in usual interstitial pneumonia (UIP). Materials and methods: After institutional review board approval and informed consent and in compliance with HIPAA regulations, we performed chest CT, pulmonary function tests (PFTs), and 129Xe MRI in 10 UIP subjects and 10 healthy controls. Results: The 129Xe MRI detected highly heterogeneous abnormalities within individual UIP subjects as compared to controls. Subjects with UIP had markedly impaired ventilation (ventilation defect fraction: UIP: 30 ± 9%; healthy: 21 ± 9%; p = 0.026), a greater amount of 129Xe dissolved in the lung interstitium (tissue-to-gas ratio: UIP: 1.45 ± 0.35%; healthy: 1.10 ± 0.17%; p = 0.014), and impaired 129Xe diffusion into the blood (RBC-to-tissue ratio: UIP: 0.20 ± 0.06; healthy: 0.28 ± 0.05; p = 0.004). Most MRI variables had no correlation with the CT and PFT measurements. The elevated level of 129Xe dissolved in the lung interstitium, in particular, was detectable even in subjects with normal or mildly impaired PFTs, suggesting that this measurement may represent a new method for detecting early fibrosis. Conclusion: The hyperpolarized 129Xe MRI was highly sensitive to regional functional changes in subjects with UIP and may represent a new tool for understanding the pathophysiology, monitoring the progression, and assessing the effectiveness of treatment in UIP.
- 25 May 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (6) , 1533
Open AccessHyperpolarized Xenon-129: A New Tool to Assess Pulmonary Physiology in Patients with Pulmonary Fibrosis
Purpose: The existing tools to quantify lung function in interstitial lung diseases have significant limitations. Lung MRI imaging using inhaled hyperpolarized xenon-129 gas (129Xe) as a contrast agent is a new technology for measuring regional lung physiology. We sought to assess the utility of the 129Xe MRI in detecting impaired lung physiology in usual interstitial pneumonia (UIP). Materials and methods: After institutional review board approval and informed consent and in compliance with HIPAA regulations, we performed chest CT, pulmonary function tests (PFTs), and 129Xe MRI in 10 UIP subjects and 10 healthy controls. Results: The 129Xe MRI detected highly heterogeneous abnormalities within individual UIP subjects as compared to controls. Subjects with UIP had markedly impaired ventilation (ventilation defect fraction: UIP: 30 ± 9%; healthy: 21 ± 9%; p = 0.026), a greater amount of 129Xe dissolved in the lung interstitium (tissue-to-gas ratio: UIP: 1.45 ± 0.35%; healthy: 1.10 ± 0.17%; p = 0.014), and impaired 129Xe diffusion into the blood (RBC-to-tissue ratio: UIP: 0.20 ± 0.06; healthy: 0.28 ± 0.05; p = 0.004). Most MRI variables had no correlation with the CT and PFT measurements. The elevated level of 129Xe dissolved in the lung interstitium, in particular, was detectable even in subjects with normal or mildly impaired PFTs, suggesting that this measurement may represent a new method for detecting early fibrosis. Conclusion: The hyperpolarized 129Xe MRI was highly sensitive to regional functional changes in subjects with UIP and may represent a new tool for understanding the pathophysiology, monitoring the progression, and assessing the effectiveness of treatment in UIP.
- Open Access
- 10 April 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (2) , 552-568
Concomitant magnetic‐field compensation for 2D spiral‐ring turbo spin‐echo imaging at 0.55T and 1.5T
Purpose: To develop 2D turbo spin‐echo (TSE) imaging using annular spiral rings (abbreviated “SPRING‐RIO TSE”) with compensation of concomitant gradient fields and B0 inhomogeneity at both 0.55T and 1.5T for fast T2‐weighted imaging.Methods: Strategies of gradient waveform modifications were implemented in SPRING‐RIO TSE for compensation of self‐squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction‐based corrections to simultaneously compensate for the residual concomitant gradient and B0 field induced phase accruals along the readout. The signal pathway disturbance caused by time‐varying and spatially dependent concomitant fields was simulated, and echo‐to‐echo phase variations before and after sequence‐based compensation were compared. Images from SPRING‐RIO TSE with no compensation, with compensation, and Cartesian TSE were also compared via phantom and in vivo acquisitions.Results: Simulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off‐resonance corrections. Volunteer data showed that after full correction, the SPRING‐RIO TSE sequence achieved high image quality with improved SNR efficiency (15%–20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low‐field (0.55T).Conclusion: Implementation of SPRING‐RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time‐varying along the echo train and temporally asymmetric in TSE‐based imaging.
- 10 April 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (2) , 552-568
Open AccessConcomitant magnetic‐field compensation for 2D spiral‐ring turbo spin‐echo imaging at 0.55T and 1.5T
Purpose: To develop 2D turbo spin‐echo (TSE) imaging using annular spiral rings (abbreviated “SPRING‐RIO TSE”) with compensation of concomitant gradient fields and B0 inhomogeneity at both 0.55T and 1.5T for fast T2‐weighted imaging.Methods: Strategies of gradient waveform modifications were implemented in SPRING‐RIO TSE for compensation of self‐squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction‐based corrections to simultaneously compensate for the residual concomitant gradient and B0 field induced phase accruals along the readout. The signal pathway disturbance caused by time‐varying and spatially dependent concomitant fields was simulated, and echo‐to‐echo phase variations before and after sequence‐based compensation were compared. Images from SPRING‐RIO TSE with no compensation, with compensation, and Cartesian TSE were also compared via phantom and in vivo acquisitions.Results: Simulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off‐resonance corrections. Volunteer data showed that after full correction, the SPRING‐RIO TSE sequence achieved high image quality with improved SNR efficiency (15%–20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low‐field (0.55T).Conclusion: Implementation of SPRING‐RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time‐varying along the echo train and temporally asymmetric in TSE‐based imaging.
- Open Access
- 16 July 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 81, 102548
Rapid Diffusion Magnetic Resonance Imaging Using Slice-Interleaved Encoding
- 16 July 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 81, 102548
Open AccessRapid Diffusion Magnetic Resonance Imaging Using Slice-Interleaved Encoding